background image

A480-15-880

Issue B Original

Instruction Manual

D-LAB Laboratory Vacuum Pumps

110 V versions are supplied with USA plug
220-240 V versions are supplied with IEC plug
100 V versions are supplied with a Japanese plug

Description

Item 

Number

D-LAB 10-100, diaphragm pump, 110 V, 60 Hz, single-phase

A480-15-941

D-LAB 10-100, diaphragm pump, 220-240 V, 50 Hz, single-phase

A480-15-960

D-LAB 10-100, diaphragm pump, 100 V, 50/60 Hz, single-phase

A480-15-933

D-LAB 20-100, diaphragm pump, 110 V, 60 Hz, single-phase

A480-17-941

D-LAB 20-100, diaphragm pump, 220-240 V, 50 Hz, single-phase

A480-17-960

D-LAB 10-100, diaphragm pump, 100 V, 50/60 Hz, single-phase

A480-17-933

D-LAB 34-100, diaphragm pump, 110 V, 60 Hz, single-phase

A480-21-941

D-LAB 34-100, diaphragm pump, 220-240 V, 50 Hz, single-phase

A480-21-960

D-LAB 10-100, diaphragm pump, 100 V, 50/60 Hz, single-phase

A480-21-933

D-LAB 10-8, diaphragm pump, 110 V, 60 Hz, single-phase

A480-16-941

D-LAB 10-8, diaphragm pump, 220-240 V, 50 Hz, single-phase

A480-16-960

D-LAB 10-100, diaphragm pump, 100 V, 50/60 Hz, single-phase

A480-16-933

D-LAB 20-8, diaphragm pump, 110 V, 60 Hz, single-phase

A480-18-941

D-LAB 20-8, diaphragm pump, 220-240 V, 50 Hz, single-phase

A480-18-960

D-LAB 10-100, diaphragm pump, 100 V, 50/60 Hz, single-phase

A480-18-933

D-LAB 34-8, diaphragm pump, 110 V, 60 Hz, single-phase

A480-22-941

D-LAB 34-8, diaphragm pump, 220-240 V, 50 Hz, single-phase

A480-22-960

D-LAB 10-100, diaphragm pump, 100 V, 50/60 Hz, single-phase

A480-22-933

Содержание A480-15-933

Страница 1: ...ingle phase A480 17 933 D LAB 34 100 diaphragm pump 110 V 60 Hz single phase A480 21 941 D LAB 34 100 diaphragm pump 220 240 V 50 Hz single phase A480 21 960 D LAB 10 100 diaphragm pump 100 V 50 60 Hz...

Страница 2: ...pump 115V 50Hz single phase A480 21 941 D LAB 34 100 diaphragm pump 230V 50Hz single phase A480 21 960 D LAB 34 8 diaphragm pump 100 V 50 Hz single phase A480 22 933 D LAB 34 8 diaphragm pump 115V 50...

Страница 3: ...Contents 9 Specifications IS 10 Performance Graphs 16...

Страница 4: ...4 Baseplate 5 Locating pin for pump 6 Support Bar for Condenser 7 Support Bar forVacuum Controller 8 Separator 9 Holder for Separator 10 Hose connector II High performance Condenser 12 Flask for conde...

Страница 5: ...Only authorized personnel should open those parts of the casing that contain live electrical parts Before using the D LAB carefully study the operating instructions Avoid dangerous situations by obser...

Страница 6: ...the pump is se Ui curely fastened to the Base b 0 a a plate via both shock mounts a b a a Figure6 Pump Mounting Arrange ment Before interchanging pumps the pump on the baseplate must be disconnected f...

Страница 7: ...Elec trical Supply Unit socket marked Pump Power Connec tor To ensure correct functioning of the system the mains connection of the pump must be plugged into this desig nated socket Neatly tuck all o...

Страница 8: ...he Information Sheet that accompanies the accessories Choose tube material which is resistant to the media used SCCTubing of twin head pumps 2 cling ater t Connect both Vacuum Controller connections S...

Страница 9: ...be used with gases which can be mixed safely together Don t operate the pump D LAB system in an atmos phere containing explosive gases Before getting started Specific safety instructions for the media...

Страница 10: ...hment nozzles back on 4 3 2 Operation with Baseplate Separator and High Performance Condenser Meaning of the LEDs I Seven segment display for vacuum mbar 6p mbar and 6p 2 Setpoint in mbar hPa Preset v...

Страница 11: ...he Regulation Mode dis play element goes out Act Value display element illuminates c Press Start Stop key to stop pumping 4 3 3 8 Venting the System If the vacuum system is to be vented or purged with...

Страница 12: ...lers can control two sepa rate processes simultaneously and independently This is made possible by using two Vacuum Valves each controlled byone Vacuum Controller Each of the two Vacuum Controllers op...

Страница 13: ...phragm into the groove in the housing Changing the Valve Plates Unscrew the single screw in the top plate pump head Carefully remove the top plate exposing the sealing rings and the valve plates Caref...

Страница 14: ...the shim washers have been replaced onto the diaphragm screw thread Check the interconnecting pipework connection be tween both pump heads as well as the tubing for leaks Possibly the screws on one of...

Страница 15: ...to be pumped Weight of pump Power Consumption Pump W Electrical Specification Fuse Pump 2x T A 6 3 6 3 3 15 9 3 Vacuum Controller Power Consumption Pump W 180 FusePump 2x T A 6 3 6 3 2 5 Electrical Ty...

Страница 16: ...e represents D LAB 10 100 Pump down time for 10 litre receiver 800 600 400 c E 200 1 0 Dashed line represents D LAB 20 100 Dashed line represents D LAB 34 100 Dashed line represents D LAB 34 100 t El...

Страница 17: ...This page has been intentionally left blank...

Страница 18: ...This page has been intentionally left blank...

Страница 19: ...of Vacuum equipment and Components Procedure HS1 If you are returning a vacuum pump note the following If a pump is configured to suit the application make a record of the configuration before return...

Страница 20: ...P800 80 000 Issue T edwardsvacuum com...

Отзывы: