4 NON-SCRATCH PADS ON THE BACK OF METER
HARD COAT OR SOFT COAT LOW E APPLICATIONS
ULTRA-SENSITIVE CIRCUITRY
SIMPLE BATTERY TEST
NO ADJUSTMENTS OR CALIBRATIONS NECESSARY
SMALL, PORTABLE CONVENIENT SIZE
GENERAL DESCRIPTION:
FEATURES:
MODEL #CM1030
LOW E CONTACT METER
RELATED PRODUCTS FROM EDTM, INC.
EASY-TO-READ
INDICATOR
01/2001 cm1030\opman01.cdr
CM1030 WARRANTY
The manufacturer warrants all models of the CM1030 to be free from defects in material
and workmanship under normal use and service as specified within the operator's
manual. The manufacturer shall repair or replace the unit within ninety (90) days from the
original date of shipment after the unit is returned to the manufacturers factory, prepaid
by the user, and the unit is disclosed to the manufacturers satisfaction, to be thus
defective. This warranty shall not apply to any unit that has been repaired or altered
other than by the manufacturer. The aforementioned provisions do not extend the
original warranty period of the unit which has been repaired or replaced by the
manufacturer. Batteries are not covered by warranty.
EDTM, Inc. assumes no liability for the consequential damages of any kind through the
use or misuse of the CM1030 product by the purchaser or others. No other obligations or
liabilities are expressed or implied. All damage or liability claims will be limited to an
amount equal to the sale price of the CM1030.
CONVENIENT BATTERY
REPLACEMENT
SIMPLE BATTERY-TEST
PUSH-BUTTON
BATTERY REPLACEMENT
The CM1030 is powered by a 9 volt battery. To test the battery voltage, simply push the
Battery Test button on the front of the meter. If the indicator lights, the battery voltage is
sufficient to operate the meter. If the indicator appears dim, you may choose to
replace the battery. To replace the battery, remove the battery cover near the
bottom of the meter and replace with a new battery. Alkaline batteries will provide the
longest service, but are not required for this product.
The CM1030 is a simple instrument that detects any conductive
surface, including Low E coatings on single sheets of glass. The low-
cost tester has 4 non-scratch pads on the back-side of the meter that
allow you to test for conductive coatings (VIA CONTINUITY). Simply
press the meter against a piece of glass to determine if the surface you
are touching contains any conductive (Low E) coatings.
NEAR
FAR
CLEAR
YELLOW
RED
GREEN
ALL LIGHTED
THE LOW-E COATING
IS ON THE
NEAR PANE
THE LOW-E COATING
IS ON THE
FAR PANE
THE WINDOW IS
CLEAR OF ANY
LOW-E COATING
THE ETEKT+ IS
CONTACTING THE
LOW-E COATED
SURFACE
CONTACTING
LOW E
(Surface 2)
(Surface 3)
(No Low E)
(Surface 1)
"ETEKT+" DUAL PANE LOW E COATING DETECTOR (MODEL# AE1600)
KEEP THE COMPETITIVE EDGE WITH PRODUCTS FROM
745 Capital Commons Drive
Toledo, Ohio 43615 USA
PHONE: (419) 861-1030 FAX: (419) 861-1031
WWW.EDTM.COM Email: [email protected]