Edsyn LONER ATMOSCOPE 971HAe Скачать руководство пользователя страница 10

Specifications

©Copyright 2015 by EDSYN®, Inc. All Rights Reserved

Designed Patented & Assembled in U.S.A.

Warranty

Edsyn stands behind its products. We warranty that new tools will be free from defects for
18 months from the date of purchase. During this time period Edsyn will repair or, at its
option, replace the tool at no charge. This warranty does not include tips and accessories.
Any  tool  that  appears  to  have  been  deliberately  abused,  altered,  or  destroyed  is  not
covered by this warranty.

Technical Support

Contact our Customer Service for assistance related to the purchase of this product or
recommendations on a challenge that you may encounter. There are many replacement
parts  that  are  available  to  keep  your  tool  in  top  condition.  To  speak  to  someone  in
Customer Service, call 818-989-2324.

No part of this publication, including individual icons, may be reproduced or utilized in any form

or by any means without the written permission of EDSYN®, Inc.

Power Requirements

120V, 60Hz

Power Rating

    15W - 220W

Heater Rating

    120V, 95W

Temperature Range

    400°F-800°F/205°C-427°C

Temperature Regulations

±6°F/±3°C

Leakage/Resistance

< 2mV/< 2 ohms

Tip-to-Ground Voltage

Overall Dimension

4.5”W x 9”H x 6.75”D

                                    114 mm x 228mm x 171 mm

Weight

    3lbs (1.4 kg)

Design, color, weight, and material subject to change without notice. Components from other designs

may be used with information pertaining to it, but not applicable to another use.

Labels and instructions will supersede this information.

.

.

           Phone: 818-989-2324
    Email: [email protected]

FAX: 818-997-0895

Internet: www.edsyn.com

Form. 971HAe

Address: 15958 Arminta St, Van Nuys, CA 91406

®

Содержание LONER ATMOSCOPE 971HAe

Страница 1: ......

Страница 2: ... 80 psi shop air Female connector to Flow Meter PR570 Flow Regulator Measures flow in cubic ft per hour Adjust flow by turning knob Turn all the way to the right to shut off the flow PAS53 Pod Air Switch Air on continuous With tool out of the pod push in on Tab to lock Air off continuous With tool in the pod push in on Tab to lock Locking Tab air off air on Temp Regulation Indicator Illuminated Gr...

Страница 3: ...one side of the SMD and again thread the wire under the leads of the opposite side 5 Anchor one end of the Pull Wire to an unused hole of the circuit board or maybe tape it securely to the board 6 While directing hot air to the leads of the first side pull the wire so that it will cut through the solder connection 7 After removing the two opposing sides follow the same procedure to desolder the re...

Страница 4: ... large air flow 06 1 5mm 25 6 4mm Method 1 LONER SMT Fan Hot Air Tip Fan Tips provide a wide air flow to cover one whole side of the SMD 17 4 3mm 30 7 6mm 59 15 0mm 35 8 9mm 65 16 5mm 43 10 9mm For Resistors Capacitors or Transistors OR Method 1 LONER SMT Fan Hot Air Tip Dual Flow Tips blow air on both sides of the SMD not on the SMD 03 0 8mm 12 3 0mm 30 7 6mm 05 1 3mm 20 5 1mm 46 11 7mm 35 8 9mm ...

Страница 5: ...s LT449 LONER SMD Quadra Flow Hot Air Tip LT478 LONER SMD Quadra Flow Hot Air Tip LT462 LONER SMD Quadra Flow Hot Air Tip LT451 LONER SMD Quadra Flow Hot Air Tip LT468 LONER SMD Quadra Flow Hot Air Tip LT477 LONER SMD Quadra Flow Hot Air Tip ______ Comes with RN432 Retaining Nut for Small Quadra Flow Tips Comes with RN433 Retaining Nut for Large Quadra Flow Tips Bendable Hot Air Tips LT571 LONER S...

Страница 6: ...ensor Dock inside the slot of the TPL09 1 2 Push the power switch and set the Temperature Control Knob to 400 F 3 Turn Flow Regulator Knob to 4 5 SCFH 4 Adjust LO Temp Calibration Pot so the Meter will read 400 F 5 Set Temperature Control Knob to 800 F 6 Adjust Hi Temp Calibration Pot so the Meter will read 800 F MS412 Digital Temperature Measurement System For a quicker calibration for more than ...

Страница 7: ...to 1C For correct fit line up tabs to slots 971HAe Exploded View 9 10 11 13 12 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 33 31 34 38 39 40 41 3 of 5 shown 42 37 35 32 36 23 Panel Pot is included when you order 22 Circuit Board Assembly 19 Ring and 20 Bushing Lens must be installed on 35 Tool Cord before 34 Cable Tie is installed to make loop 8 2 3 4 5 6 36H 36G 36F 36E 36D 36B 36A 36C 7 7...

Страница 8: ...of 4 1 25 set 8 SR367 Phillips Flat Head Screw 1 9 SR784 Single Dovetail Track 1 10 SR772 Phillips Flat Head Screw 1 11 SR1200 Housing for Soldering Station 1 12 SR1201 Front Panel Label 1 13 SR1226 Front Panel Mount Light Pipe 1 14 SR1202 Switch Button Lens Ring 1 15 SR1203 Round Chrome Switch Cap 1 16 SR1205 Dial Face Lens Cover 1 17 SR1204 Black Control Knob 1 18 SR1208 Silicone O Ring 1 19 SR1...

Страница 9: ...lete Assembly 1 36A SR525 Static Safe Silicone Black Hose 43ft 36B SR579 Handle 1 36C SR058 Strain Relief 1 36D SR574 High Performance Hollow Heater Assembly includes Shrink Sleeving 1 36E LTC71 Tip Collet 1 36F HS307 Static Safe Silicone Black Hose 5ft 36G RCS75 Retaining Collar and Sleeve for Hot Air 1 36H LT428 SMT Nozzle Hot Air Tip 1 37 SR1216 Clear Lens Base Cover 1 38 SR1217 Hex Screw 1 39 ...

Страница 10: ...o keep your tool in top condition To speak to someone in Customer Service call 818 989 2324 No part of this publication including individual icons may be reproduced or utilized in any form or by any means without the written permission of EDSYN Inc Power Requirements 120V 60Hz Power Rating 15W 220W Heater Rating 120V 95W Temperature Range 400 F 800 F 205 C 427 C Temperature Regulations 6 F 3 C Lea...

Отзывы: