background image

      

USER

MANUAL

i1-X

Содержание i1 Series

Страница 1: ...USER MANUAL i1 X ...

Страница 2: ...cator be passed on to other parties for private or professional use the content of this regulation must also be related The indicator has a rechargeable internal battery The battery contains heavy metals Please observe the local regulations on the disposal of environmentally hazardous materials 1 2 Descriptions The purpose of this manual is to help the user get to know the indicator s various weig...

Страница 3: ...ptional RS485 interface 30 hours Full charge battery recharge time 12 hours Operating temperature 10 C to 40 C Storage temperature 25 C to 55 C 1 5 kg Relative humidity 10 to 85 non condensing Housing I1 20 plastic Full charge battery operation i1 20 20 hours i1 21 21F 20 hours i1 22 i1 21 21F 6V 2 8AH i1 22 6V 2 8AH i1 23 6V 4AH 20 hours i1 23 External AC adapter 100 240VAC 50 60Hz Rechargeable i...

Страница 4: ... OK set point B weight set point C HI set point C weight set point D kg Weight unit in kilogram 3 2 Keypad Keys Operation OFF Switch the indicator off ON Switch the indicator on Manual weight accumulation Proceed to next step Display weight to X10 resolution T Tare 0 Zero 3 3 LED Error Code Code Meaning OUEr Weight FS 9d OUEr Weight 20d Error Calibration error 23 12 blink Low battery warning 10 of...

Страница 5: ...lay 5 The tare status NET is turned on 6 The indicator switches to in net weight mode 4 5 2 Remove tare 1 Check that the tare status NET is displayed 2 Press T to remove tare and switch to gross weight mode 4 6 Simple weighing 1 Place sample on the platform 2 Wait until the weight is stable when the stable status is displayed 3 Read the weight of the sample 4 7 Low battery warning When the battery...

Страница 6: ...on 1 Press OFF 0 00 Switch off the indicator 2 Press and hold T and then press ON 0 00 Switch on the indicator to enable set point menu 3 Press T A000 00 Set point A 4 Enter a number A 5 00 Use and T or 0 to enter set point A 5 00 5 Press b000 00 Set point B 6 Enter a number b 15 00 Use and T or 0 to enter set point B 15 00 7 Press C000 00 Set point C 8 Enter a number C 30 00 Use and T or 0 to ent...

Страница 7: ...arity Number of stop bit 8 No 1 6 2 2 RS232 DB9 connectors 6 2 3 Connecting DB9 to PC DB9 PC DB9 Pin No 2 RxD 3 TxD 3 TxD 2 RxD 5 GND 5 GND 6 2 4 RS232 RS485 CN5A connectors Pin No 1 2 3 4 5 6 7 8 9 CN5A RS485 A RS485 B RS232 GND RS232 RxD RS232 TxD 6 2 5 Connecting CN5A to PC DB9 PC DB9 Pin No 3 GND 5 GND 4 RxD 3 TxD 5 TxD 2 RxD DB9 RxD TxD GND Pin No 1 2 3 4 5 6 7 8 9 i1 2x i1 2x DB9 Pin No i1 2...

Страница 8: ...icator address Adr is set to 01 to 98 Serial communication follows the Modbus ASCII protocol 6 5 Printer format n 3 gross 88 69kg tare 29 41kg net 59 28kg No XXXX No 3 G XXXXXXkg G 88 69kg T XXXXXXkg T 29 41kg N XXXXXXkg N 59 28kg Accumulated weight No XXXX No 3 W XXXXXXXkg W 118 09kg 7 Model Numbers 8 Services Services include a full range of technical on site services and workshop repair prevent...

Отзывы: