E D R O
D
y n a
W
a s h
®
T
h r e e
P
o c k e T
W
a s h e r
- e
x T r a c T o r s
15
S
ection
2
It is the responsibility of the Installer to check and complete the
following items upon installation of the machine.
The installation procedure of your DynaWash
®
washer-extractor should not take more than one
day to complete. Except for re-connecting certain parts disconnected in shipping, no internal
assembly or wiring is necessary. By reading these instructions carefully and following the
recommended procedures, you will not only save time, but should avoid many unnecessary
complications and possible future problems.
INSTALLATION
For installing DynaWash
®
Rigid Mount Models (DW100, DW150, DW200, DW300, DW400, and
DW100PT, DW150PT, DW200PT) the ground floor thickness must be at least 12” (ref. page 17),
and must be constructed of the equivalent of 5,000 PSI re-enforced concrete. For upper floor
installations, check with a structural engineer to verify the capability of the floor to support the
machine’s static operating weight. Static operating weight is equal to the machine weight, a full
load of laundry and 100% full water. Before positioning the machine, be sure to have adequate
floor area to achieve a level foundation. Existing floors should be filled in if necessary to obtain
the area needed for a proper installation. DynaWash
®
rigid mount models with down drain are
designed to straddle a drain trough. Models with drain to rear option are designed to be piped
to a sewer drain. It is required that all factory supplied mounting holes in the base footings of
the machine be used to anchor the machine to the floor.
RIGID MOUNT MODELS (DW & DW_PT)
For installing DynaWash
®
with Dyna
Mount Soft Mount option (DW100SM, DW150SM,
DW200SM, DW300SM, DW400SM, and DW100PTSM, DW200PTSM, DW300PTSM DW-
400PTSM), the floor thickness must be constructed of the equivalent of 5,000 PSI re-enforced
concrete and able to support the machine’s static operating weight. For upper floor installations,
check with structural engineer to verify the capability of the floor to support the machine’s static
operating weight. Static operating weight is equal to the machine weight, a full load of laundry
and 100% full water. Even though the deflection of vibration is less than 5%, before position-
ing the machine, be sure to have adequate floor area to achieve a level foundation. This is
important so that the washer can maintain a stable and level operating environment and not
put undue stress on any components of the suspension system. To achieve this condition, the
existing floor should be filled in if necessary to obtain the area needed for a proper installation.
We require the existing four (4) holes in the machine’s base be used for anchoring the base of
the machine to the floor.
The shock absorbers and reverse loaded coil springs on Dyna
Mount units are pre-adjusted at
the factory, however, final adjustments maybe necessary and should be made as follows:
DYNA
MOUNT SOFT MOUNT MODELS (DW_SM & DW_PTSM)