Auto Range Hi-Accuracy Digital
Multimeter - USB Interface

ORDER CODE: EDI-516-3420K

MODEL  DAM100

5163420K_Instructions.qxd  18/09/2009  12:56  Page 1

Содержание DAM100

Страница 1: ...e eq qu ue en nc cy y t te es st ti in ng g f fr ro om m 5 5H Hz z t to o 2 2M MH Hz z D Du ut ty y c cy yc cl le e t te es st ti in ng g f fr ro om m 5 5 t to o 9 95 5 D Di io od de e t te es st ti i...

Страница 2: ...and pollution level 2 To get the best service from this instrument read carefully this user manual and respect the detailed safety precautions 1 1 Precautionary safety measures Preliminary When using...

Страница 3: ...s When the value scale to be measured is unknown beforehand ALWAYS set the range dial at the highest position NEVER exceed the protection limit values indicated in the specifications for each range of...

Страница 4: ...e meter will return back to the automatic state When performing logic frequency measurement the diode measurement pressing R RA AN NG GE E will be void During dBm measuring pressing the R RA AN NG GE...

Страница 5: ...other 2 seconds and the PC LINK mode will revert back to normal 5 High Accuracy Digital Multimeter with USB Interface 13 L LI IG GH HT T key By pressing this key the backlight of the LCD screen will b...

Страница 6: ...sures in the automatic range 4 M MA AN NU UA AL L Measures in the manual range 5 5 51 10 00 00 0 Indicator of range indicating the full range value of this range in manual range such as 5 50 500 and 1...

Страница 7: ...k resistant rubberised meter casing with 1000V CATIII protection REFERENCE NUMBER SYMBOL FUNCTION 11 D DC C Indicating it is now in the DC measurement state while DC and AC displaying simultaneously i...

Страница 8: ...ter power is set to the Automatic range by defaults AUTO displaying and simultaneously it will automatically select the proper range according to the measured electric parameters If OL is displayed un...

Страница 9: ...a long time If you want the meter to operate continuously without automatically turning off it can be done by holding down the W WA AK KE E key when turning on the power L Lo ow w V Vo ol lt ta ag ge...

Страница 10: ...sary to remove both the red and black probes from the measured circuit immediately to avoid damage to the meter 7 To perform d dB Bm m measurement press the R RA AN NG GE E key to select the resistanc...

Страница 11: ...nd DC measurements and to calculate RMS 3 3 DC mV AC mV DC mV AC mV Measurement DO NOT try to measure voltage higher than 1000V Select m mV V Voltage ranges from 1 V to 500mV 1 Turn on the power and s...

Страница 12: ...uency of the measured signal is lower or higher than the meters measurement range the reading will display zero If the amplitude of signal is too low or the low level is larger than 1 volt the reading...

Страница 13: ...E E Under the continuity measurement mode it is not possible to use manual mode In case of performing resistance or continuity test on a circuit board it is necessary firstly to turn off the power of...

Страница 14: ...ays as _ negative the current is flowing into the meter from the black testing line If it displays as OL it means current exceeding range 6 During measurement of DC A or AC A it is possible to select...

Страница 15: ...he black testing line into the C CO OM M input port 3 Press the S SE EL LE EC CT T key to select the D DC C A A A AC C A A or D DC C A A A AC C A A measurement modes 4 Turn OFF the power of the measur...

Страница 16: ...produced so only when current reaching as large as over 5A can the frequency be measured 3 12 Relative Value Measurement Except for frequency duty ratio and diode measurements all other measurements...

Страница 17: ...tinuously judges if it is necessary to update the maximum or minimum value Pressing the M MA AX X M MI IN N key again will allow you to select the minimum value Press the M MA AX X M MI IN N key again...

Страница 18: ...ns into the front socket of the meter and another end into the computer USB interface and run the record and graphics software options Press the H HO OL LD D key for 2 seconds and then release it agai...

Страница 19: ...d relative humidity less than 80 The presentation for accuracy is reading digits number of lower digits AC Voltage DC Voltage AC Voltage N No ot te es s above accuracies can be guaranteed within 10 to...

Страница 20: ...Hz 20KHz DROP 500 A 0 01 A 0 75 20 1 20 2 20 102 V A 5000 A 0 1 A 0 75 10 1 10 2 10 50mA 1 A 0 75 20 1 20 2 20 1 5mV mA 500mA 10 A 0 75 10 1 10 2 10 5A 0 1mA 0 75 20 1 5 20 5 20 30mV A 10A 1mA 1 10 1...

Страница 21: ...io RANGE RESOLUTION ACCURACY 50nF 0 01nF 1 5 500nF 0 1nF 1 5 5 F 1nF 1 5 50 F 10nF 1 5 500 F 0 1 F 2 5 5000 F 1 F 2 5 RANGE RESOLUTION ACCURACY 2 5V 0 1mV 1 5 FREQUENCY RANGE SENSITIVITY ACCURACY 5Hz...

Страница 22: ...o make sure they are not put back incorrectly The meter must not be used until the cover of fuses is replaced properly Notes generally fuses will not blow under the normal use of the meter It is neces...

Страница 23: ...ows 98ME 2000 NT or XP 6x 1 5V AAA batteries installed Instruction manual Presentation case with carry strap P PC C L LI IN NK K s so of ft tw wa ar re e f fe ea at tu ur re es s Measure graph Measure...

Страница 24: ...developed and improved All details and illustrations are for guidance and may be subject to change EDISON The Power Factory PO Box 14 Wigston Leicester England ISO 9001 Registered Company 5163420K_Ins...

Отзывы: