Содержание CMU 100 / 1.1.5 - 0

Страница 1: ...MU 100 1 1 M 0 CMU 100 1 1 L 0 CMU 100 7 1 5 0 CMU 100 7 1 M 0 CMU 100 7 1 L 0 Company Device Document Code Date Ediseja 21 CMU 100 1 1 5 0 User manual CMUMU115 01 09 2019 CMU 100 RS232 to RS485 Conve...

Страница 2: ...3 3 APPEARANCE 8 3 4 HARDWARE DESCRIPTION 8 3 4 1 MAIN BOARD 8 3 4 2 RS232 INTERFACE BOARD 9 3 4 3 RS485 INTERFACE BOARD 10 4 SCHEMATIC 13 5 INSTALLATION 14 5 1 INSTALLATION 14 6 COMMISSIONING MAINTEN...

Страница 3: ...egne 21C 1000 Ljubljana Slovenia EU Tel 00 386 51 643 411 051 643 411 Email grega flander ediseja21 com www ediseja21 com Copyright Copyright Ediseja 21 2019 All rights reserved Explanation of the sym...

Страница 4: ...e during operation Disregarding of safety rules can result in severe personal injury or property damage Only qualified personnel may work with described devices after being familiar with warnings and...

Страница 5: ...e s task is switching between communication ports and allows almost any combination between them 2 1 2 HARDWARE Hardware is based on main board with power supply and port switching logic On that board...

Страница 6: ...CMU 100 RS232 to RS485 Converter Page Company Device Document Code Date 6 Ediseja 21 CMU 100 1 1 5 0 User manual CMUMU115 01 09 2019 Picture 1 CMU 100 system general diagram...

Страница 7: ...y it can be also connected to standard AC voltages This device is intended for use in cubicles and cabinets in all kinds of power production transmission and distribution stations It requires no maint...

Страница 8: ...uration of device is made from main board power supply LEDs one RS232 interface board and one RS485 interface board 3 4 1 MAIN BOARD Page Company Device Document Code Date 8 Ediseja 21 CMU 100 1 1 5 0...

Страница 9: ...INTERFACE BOARD Description Single nonisolated full duplex RS232 port with DB9 female connector Supported Rx Tx and GND pins Connector pin table DB9 F 2 3 5 Description RX TX GND Direction IN OUT Cab...

Страница 10: ...demands that RS485 must always be in known and valid state That is when positive pin is more than 200 mV positive than negative pin Pins and are sometimes marked as A and B In case that no device on R...

Страница 11: ...l timings If special protocols small request respond time required are used please note it in order NOTE If there are problems with communication try using higher speed setting Some manufacturer have...

Страница 12: ...CMU 100 RS232 to RS485 Converter Page Company Device Document Code Date 12 Ediseja 21 CMU 100 1 1 5 0 User manual CMUMU115 01 09 2019 Picture 8 Standard data rate vs cable lenght...

Страница 13: ...SCHEMATIC 4 SCHEMATIC Company Device Document Code Date Page Ediseja 21 CMU 100 1 1 5 0 User manual CMUMU115 01 09 2019 13 Picture 9 General diagram...

Страница 14: ...dmisible operating temperature must be observed Check the device for damage at unpacking If device is damaged it must not be installed but it should be send to the manufacturer for repair The device s...

Страница 15: ...INSTALLATION Company Device Document Code Date Page Ediseja 21 CMU 100 1 1 5 0 User manual CMUMU115 01 09 2019 15 Picture 10 left installation right deinstallation...

Страница 16: ...rate completely assembled Device must be used as described No modifications of the device should be made Attach ground wire before attaching power supply Device must be grounded during operation Check...

Страница 17: ...rossection 0 5 2 5 mm2 type single or stranded wire voltage rating 500 V colour see valid standard Ground wire crossection Cu 2 5 mm2 colour see valid standard Communication port RS232 interface type...

Страница 18: ...r of devices on RS485 bus 32 slowest interface defines device s maximum speed Other data Weight approx 0 3 kg Dimensions see picture H D W 105 mm 111 mm connectors 40 mm Temperature range 0 C to 55 C...

Страница 19: ...DIMENSIONS 8 DIMENSIONS Company Device Document Code Date Page Ediseja 21 CMU 100 1 1 5 0 User manual CMUMU115 01 09 2019 19 Picture 11 Dimensions...

Страница 20: ...connector up to 2 048 Mbit s 500 m 6 Multimode 820 nm fiber optic with SMA connector up to 2 048 Mbit s 500 m 7 Singlemode 1310 nm fiber optic with SC connector up to 2 048 Mbit s 20 km S Singlemode 1...

Страница 21: ...e power supply CMU 100 1 6 S 0 FO MM FO SM FC connector 20 km up to 2 048 Mbit s high voltage power supply CMU 100 1 6 T 0 FO MM FO SM ST connector 20 km up to 2 048 Mbit s high voltage power supply C...

Страница 22: ...RS232 RS485 to 6 x RS232 CMU 100 2 5 1 1 1 1 1 1 12 7 x RS232 RS485 to 7 x RS232 CMU 100 2 5 1 1 1 1 1 1 1 12 2 x FO MM RS485 to 2 x multimode fiber optic CMU 100 2 5 6 6 12 3 x FO MM RS485 to 3 x mul...

Страница 23: ...FO MM 6 x FO MM 8 channel star coupler RS232 multimode fiber optic to 6 x multimode fiber optic high voltage power supply CMU 100 2 1 6 6 6 6 6 6 6 5 4 xFO MM 4x RS232 4 channel converter multimode fi...

Отзывы: