53
Reference
You can use the REMOTE connector to enable switching, control of
effects, and other operations from a computer or other external
control device.
*
For more on control using the REMOTE connector, refer to
“REMOTE Command Reference” (p. 66).
REMOTE Connector Specifications
• Transmission Format: Start-stop synchronization
(asynchronous), full duplex
• Transmission Rate: 9600 bps (Initial setting)/19200 bps
(This can be changed in the menu with “8. REMOTE Baudrate”
under “13. System” (p. 64).)
• Parity: None
• Data Length: 8 bits
• Stop Bit Length: 1 bit
• Encoding: ASCII
• Flow Control: XON/XOFF
*
The V-440HD’s connectors are male. To connect to a computer, use a
female-female crossover cable.
Cable Connections:
Setup Procedure
Use the following procedure to set up the control device and
V-440HD.
1.
Connect the V-440HD and control device with a REMOTE
cable.
2.
Turn on the power to the control device.
3.
Set the communications protocol for the control device.
4.
Turn on the power to the V-440HD.
5.
Begin operation.
*
For more on commands, refer to “REMOTE Command Reference” (p.
66).
Backing Up the Settings from the
REMOTE Connector to a Computer
You can back up the V-440HD’s settings data by connecting the V-
440HD’s REMOTE connector to a computer’s RS-232C connector.
For more detailed information, refer to “Saving the V-440HD’s
Settings to a Computer” (p. 48).
About the REMOTE Connector
Pin number
Signal name
Pin Connections
1
DCD
2
RXD
3
TXD
4
DTR
5
GND
6
DSR
7
RTS
8
CTS
9
RI
5
1
9
6
1 : DCD
2 : RXD
3 : TXD
4 : DTR
5 : GND
6 : DSR
7 : RTS
8 : CTS
9 : RI
1 : DCD
2 : RXD
3 : TXD
4 : DTR
5 : GND
6 : DSR
7 : RTS
8 : CTS
9 : RI