Edin Univox 1370.11161 Скачать руководство пользователя страница 1

 

Installation Guide

Univox

®

 PLS-6

High-Power

Class D Tech Series

Univox

®

 PLS-6   part no. 225060

Содержание Univox 1370.11161

Страница 1: ...Installation Guide Univox PLS 6 High Power Class D Tech Series Univox PLS 6 part no 225060...

Страница 2: ...Start up procedure 8 Input connection and adjustments 8 Output connection and adjustments 8 Metal Loss Correction frequency setting 10 Troubleshooting 10 MLC function in maximum position 11 Safety 12...

Страница 3: ...durable performance and easy installation The combination of Univox technology electronic transformer and silent fan free operation delivers an unsurpassed loop driver with high audio quality The ext...

Страница 4: ...5 7 6 8 11 12 PLS 6 11 DC supply input 12 Loop screw terminals 13 Monitor volume control for both headphones and speaker output A MISCELLANEOUS OUTPUTS 14 Monitor speaker connector 15 Auxiliary DC pow...

Страница 5: ...D 27 26 25 24 22 21 20 19 18 17 16 15 14 23 C INPUT 2 20 Speech enhancement switch Flat Speech 21 50 100 V Line switches On Off 22 Override switch On Off Input 3 23 Phoenix screw terminal D INPUT 1 24...

Страница 6: ...op current LED bar graph 7 indicates the level of the loop current not the field strength The field strength is measured using a Field Strength Meter like the Univox FSM 8 Peak clip LED 8 illuminate w...

Страница 7: ...eld strength level and frequency response this feature must be switched to Flat postition 21 Speaker 50 100V balanced Line sensitivity On Off Caution 50 100 V Line must be set prior to any further set...

Страница 8: ...single double and twin turn loop connections Use a feed cable twisted or twin wire between the junction box and the loop driver as well as between the loop figuration and the junction box or loop driv...

Страница 9: ...nt along metal bars Maximum recommended segment size in compliance with IEC 60118 4 Placement of the microphones Microphone placement and proximity between microphone and sound source is crucial for i...

Страница 10: ...ten more efficient See page 9 7 Check field strength for all loop segments using a field strength meter e g Univox FSM Verify low field strength directly above wires and high in between segments peaks...

Страница 11: ...aring aids 14 Check basic frequency response according to IEC 60118 4 using a field strength meter e g Univox FSM If necessary follow Frequency adjustment procedure see page 10 15 Check the sound qual...

Страница 12: ...ric MLC set too high Re run startup procedure page 10 Change the loop cable use twin cores in parallel or use a cable with higher cross section Adjust loop curremt Adjust the Parametric MLC Audio qual...

Страница 13: ...king distance Use valid microphone or connect a microphone mixer amplifier Exchange faulty part Alarm priority signal is not clear Override DIP switch not set to allow this function Set DIP switch to...

Страница 14: ...ing to qualified personnel Please observe that the product warranty does not include faults caused by tampering with the product carelessness incorrect connection mounting or maintenance Bo Edin AB sh...

Страница 15: ...please refer to product data sheet and CE certificate which can be downloaded from www univox eu products If required other technical documents can be ordered from support edin se Environment To prev...

Страница 16: ...0Hz Distortion Power Loop Driver 0 05 Distortion system 0 15 Dual Action AGC Dynamic Range 50 70dB 1 5dB Attack time 2 500ms Release time 0 5 20dB s Cooling Fan free convection cooling chassis cooling...