 SNAP

 Lighting Control Panel

 

Pathway  Connectivity’s  SNAP  Lighting  Control  Panels 
provide  unified  DMX512  control  of  0-10VDC  outputs  and 
relay switching from a single enclosure.  Intended for use 
with  LED  drivers  requiring  mains  switching  and  0-10V 
dimming and fluorescent ballasts controllers. 

 

Each  SNAP  Panel  consists  of  an  LC&D  GR1400-series 
relay  panel  with  a  Pathway  Connectivity  eDIN  SNAP 
Panel  Interface  Controller.    The  interface  provides 
DMX512  signal  control  over  relay  and  analog  output 
pairs.  The  interface  also  provides  a  full  non-sequential 
DMX soft-patch, for maximum flexibility. 

IMPORTANT SAFEGUARDS 

Models 

4850-8, 4850-16 

INSTALLATION: MECHANICAL 

1.  Mount relay panel to suitable surface with appropriate 
hardware. 

3/4", 1", 1-1/4"
Knockouts
(line voltage only)

3/4", 1", 1-1/4"
Knockouts
(line voltage only)

3/4" Knockouts

(low voltage)

1/4" Mounting

Holes

18"

12"

6"

CABLE

CABLE

W

ARNING

:  R

OUTING

 

LINE

 

VOLTAGE

 

CABLES

 

THROUGH

 

THE

 

SIDES

 

OF

 

THE

 

ENCLOSURE

 

IS

 

NOT

 

ALLOWED

 

AS

 

IT

 

WILL

 

VIOLATE

 NEC 

REQUIREMENTS

 

SEPARATING

 

C

LASS

 1 

AND

 C

LASS

 2 

CIRCUITS

 
2. Plan where to land the Line and Load conductors be-
fore routing cables.  Write down your plan. 
  

Cont’d... 

INSTALLATION/ 

CONFIGURATION 

SNAP Panel Controller 

DMX  TERMINATE

POWER IN

DMX INPUT

STATUS

THRESHOLD

DMX DISP

RELAY TEST

AUX-IN

PATCH

ADDRESS

ENTER

OFF

ON

ESC

D1+

AUX2

AUX1

COM

D1-

D1+

D1-

SHLD

COM

SHLD
COM

D

M

X

 IN

D

M

X

 T

H

R

U

0

-1

0

V

 A

N

A

L

O

G

 O

U

T

P

U

T

S

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

OUTPUT

ON

OFF

E

V

E

N

R

E

L

A

Y

O

U

T

P

U

T

S

O

D

D

R

E

L

A

Y

O

U

T

P

U

T

S

P

O

W
E

R

 IN

P

U

T

A

U

X

 IN

P

U

T

S

BYPASS

1.   D

O

 

NOT

 

INSTALL

 

OR

 

USE

 

OUTDOORS

2.  E

QUIPMENT

 

SHOULD

 

BE

 

MOUNTED

 

IN

 

LOCATIONS

 

AND

 

AT

 

HEIGHTS

 

WHERE

 

IT

 

WILL

 

NOT

 

READILY

 

BE

 

SUBJECTED

 

TO

 

TAMPERING

 

BY

 

UNAUTHORIZED

 

PERSONNEL

3.  T

HE

 

USE

 

OF

 

ACCESSORY

 

EQUIPMENT

 

NOT

 

RECOMMEND-

ED

 

BY

 

THE

 

MANUFACTURER

 

MAY

 

CAUSE

 

AN

 

UNSAFE

  

CONDITION

 

4.  D

O

 

NOT

 

USE

 

THIS

 

EQUIPMENT

 

FOR

 

OTHER

 

THAN

 

INTEND-

ED

 

USE

5.  U

SE

 

THIS

 

INSTALLATION

 

GUIDE

 

FOR

 

RELAY

 

HOOK

-

UP

  

DIRECTIONS

FOR

 

DATA

 

WIRING

 

OF

 

THE

 

INTERFACE

 

CARD

AND

 

FOR

 

INTERFACE

 

CONFIGURATION

6.  T

HIS

 

PRODUCT

 

IS

 

NOT

 

INTENDED

 

FOR

 

USE

 

WITH

  B

LUE

 

B

OX

 

PROGRAMMABLE

 

INTERFACES

 

OTHER

 

THAN

 

THE

 

P

ATHWAY

  SNAP 

INTERFACE

 

MODULE

.    M

AKE

 

ALL

 

CON-

NECTIONS

 

WITH

 

THE

 

POWER

 OFF. 

Отзывы: