background image

 

 

II-2.

 

Connection 

 

1.

 

Power on

: Connect the power cord to the switch and the power outlet. 

The switch is powered by the 100-240VAC 50/60Hz external high- 
performance power supply. (Note: Make sure the PWR LED is green.) 
 

2.

 

Uplink

: Plug the standard Cat5e(or above) Ethernet cable into the LAN 

port no. 9 or plug the SFP cable into the SFP slot and connect it to the LAN 
server or core switch. (Note: Make sure that the LED is green or amber.)

 

 

3.

 

Connect devices

: Plug the standard Cat5e(or above) Ethernet cable into 

the LAN port and connect to any networking device with an Ethernet port. 
(Note: Make sure that the "LAN" LED is green or amber.) The hardware 
installation is complete!

 

 

4.

 

Connect a computer

: Connect your computer with the switch and get 

ready for web-based configuration with following 

Section III 

Web-based Configuration Utility

 

 

 

 

 

 

1.

 

Power on 

3. Connect devices

 

2.

 

Uplink to the server 
or core switch 

4. Connect to 

a computer

 

Содержание GS-5210PLG

Страница 1: ...GS 5210PLG User Manual 03 2022 v1 0...

Страница 2: ...stallation 3 II 1 Physically Setup 3 II 2 Connection 5 III Web based Configuration Utility 6 IV Web based Switch Configuration 8 IV 1 System 8 IV 2 Management 9 IV 3 Port 11 IV 4 Long Range Mode 12 IV...

Страница 3: ...8 3 IEEE 802 1p QoS 19 IV 9 Broadcast Storm Control 20 IV 10 Rate Limiting 21 IV 11 Loop Detect Prevent 22 IV 12 IGMP Snooping 23 IV 13 PoE 24 IV 14 Password 25 IV 15 Logout 25 V Safety Instructions...

Страница 4: ...brackets allow for integration with the most widely used mounting systems on the market The Edimax GS 5210PLG is a superb choice to boost your network environment s performance and efficiency You can...

Страница 5: ...the package and contact your dealer to claim the missing item s I 2 Hardware Overview Power Cord Rack Mount Kit GS 5210PLG LED PoE Alert PWR LED Link Act 1 8 Reset Gigabit PoE Port 1 8 PoE LED Link A...

Страница 6: ...R Green On Power on Off Power off Blinking Booting up PoE Alert Green On Total PoE power consumed is OVER PoE power budget Off Total PoE power consumed is under PoE power budget Link ACT Port 1 9 Gree...

Страница 7: ...1U of space which is 1 75 inches 4 45 cm high A pair of extension brackets and screws are needed to adapt the switch to the rack size Align the mounting brackets with the mounting holes on the switch...

Страница 8: ...AN server or core switch Note Make sure that the LED is green or amber 3 Connect devices Plug the standard Cat5e or above Ethernet cable into the LAN port and connect to any networking device with an...

Страница 9: ...you have multiple IPv6 interfaces on your management station use the IPv6 global address instead of the IPv6 link local address to access the device from your browser Launching the Configuration Utili...

Страница 10: ...7 3 The default username is admin and the default password is 1234 4 The first time that you log in with the default username and password you are required to change password...

Страница 11: ...e the switch s features For the purposes of this manual of GS 5210PLG the user interface is separated into fifteen sections as shown in the following figure IV 1 System This page shows system current...

Страница 12: ...AC Address Base MAC address of the switch IPv4 Address Current system IPv4 address Subnet Mask A 32 bit number that masks an IP address Gateway TCP IP protocol under the gateway Loop Status Displays w...

Страница 13: ...ion The gateway must be in the same subnet with switch IP address configuration Item Description Management Reboot You can reboot the switch by pressing the Reboot button Reset You can reset the switc...

Страница 14: ...ed with Half Duplex 10M Full Speed with Full Duplex 100M Half Speed with Half Duplex 100M Full Speed with Full Duplex Connection Down Displays port is not in use Or link speed if it is in use TX Pkts...

Страница 15: ...or Disable to enable or disable Long Range Mode NOTE Enable long range mode will double the cabling distance but reduce the speed to 10Mbps IV 5 VLAN This page allows user to configure each port of se...

Страница 16: ...f a port which is a member of the VLAN Untag Egress Member Untag outgoing packets of a port which is a member of the VLAN Modify Modify port settings of a specific VLAN Delete Delete a specific VLAN N...

Страница 17: ...ange the member state There are 3 VLAN member states Click on the box Default to change each the member state and click Apply SimpleClick Delete button to delete the targeted VLAN Note If the VLAN ID...

Страница 18: ...the ports at the remote end of a link to establish trunk groups LACP also allows port redundancy that is if an operational port fails then one of the standby ports become operational without user int...

Страница 19: ...Active By default the Switch uses the Passive mode Link Group Member The check box of ports would be checked after the port is added into the Link Group successfully Apply Click Apply to save your ch...

Страница 20: ...d for traffic forwarding port based QoS and 802 1p QoS Users can switch to either of them on the Web page When Quality of Service QoS feature is enabled traffic will be forwarded according to the pred...

Страница 21: ...Low Priority Queue1 Normal Priority Queue2 Medium Priority Queue3 High Priority Item Description Schedule Method WFQ Weighted Fair Queue Strict Priority Weight WFQ Method ONLY WFQ weight options Apply...

Страница 22: ...ent queue for each PCP is configured as below PCP value Priority Acronym Traffic types 1 0 lowest BK Background 0 1 default BE Best effort 2 2 EE Excellent effort 3 3 CA Critical applications 4 4 VI V...

Страница 23: ...raffic storm occurs when packets flood the network ports creating traffic and impacting network performance in a negative way The broadcast storm control feature prevents network ports from being disr...

Страница 24: ...feature is enabled GS 5210PLG provides Ingress Egress traffic Rate Control per port for broadcast traffic type Enable this feature to reduce broadcast packets in your network Click on a port number to...

Страница 25: ...to change the Ingress Egress rate and click Apply to apply the setting IV 11 Loop Detect Prevent Users can choose to enable Loop Detection or Loop Prevention Item Description Off By Default Loop Dete...

Страница 26: ...protocol messages within a VLAN to discover which interfaces are connected to hosts or other devices interested in receiving this traffic Using the interface information IGMP snooping can reduce bandw...

Страница 27: ...24 IV 13 PoE Click on a port number and the options are shown below Click the drop down menu to select whether to Turn on or Turn off PoE function Click Apply to apply the settings...

Страница 28: ...25 IV 14 Password In this page you can change the user name and password Click the Confirm button to save the changes IV 15 Logout Click the Logout button to exit the Web Management UI of GS 5210PLG...

Страница 29: ...body i e touching grounded bare metal before touching the product The device contains no user serviceable parts Do not attempt to service the product and never disassemble the product Do not spill fo...

Страница 30: ...old or licensed as is Should the programs prove defective following their purchase the buyer and not this company its distributor or its dealer assumes the entire cost of all necessary servicing repai...

Страница 31: ...nditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Caution Any changes or modif...

Страница 32: ...tlinien 2014 30 EU Espa ol El presente equipo cumple los requisitos esenciales de la Directiva 2014 30 EU Italiano Questo apparecchio conforme ai requisiti essenziali e alle altre disposizioni applica...

Страница 33: ...quirements have been followed Directives 2014 30 EU EMC EN 55032 2015 AC 2016 EN 61000 3 2 2014 Class A EN 61000 3 3 2013 EN 55035 2017 Directives 2014 35 EU Safety LVD EN 62368 1 2014 A11 2017 Date P...

Страница 34: ...lectromagnetic Compatibility Regulations 2016 S I 2016 1091 EMC EN 55032 2015 AC 2016 EN 61000 3 2 2014 Class A EN 61000 3 3 2013 EN 55035 2017 Electrical Equipment Safety Regulations 2016 S I 2016 11...

Отзывы: