7
ENGLISH
EDILKAMIN S.p.A. The manufacturer reserves the right to modify the product without
notification in the interests of improvement.
TECHNICAL DATA
USER/INSTALLER
ELECTRICAL SPECIFICATIONS
Power supply
230 V AC +/- 10% 50 Hz
Nominal absorbed power
126 W
Reduced absorbed power
23 W
Absorbed power in stand-by mode
3 W
Power absorption during ignition
365 W
Remote control frequency (provided)
2.4 GHz
Protection rating
Fuse 4 AT 250 V AC 5x20
TECHNICAL CHARACTERISTICS pursuant to EN 14785
The data shown is purely indicative and was
measured during the certification phase at a notified body under standard conditions.
The results were obtained with the glass cleaning system off. Use the gasket provided (to
be done by the installer).
CHERIE 9 EVO
Air Tight C
Nominal power
Reduced power
Available power
9.3
3.6
kW
Yield
92.5
95
%
CO emissions at 13% O
2
0.001
0.005
%
Smoke temperature at smoke outlet
188
82
°C
Fuel consumption *
2.1
0.8
kg/h
Tank capacity
18
kg
Draw
10
10
Pa
Autonomy ***
9
23
hours
Heatable volume **
240
--
m
3
Smoke duct diameter
80
mm
Weight including packaging
(steel/ceramic/soap stone)
216/218/250
--
kg
Energy efficiency class in accordance with EU
regulation 2015-1186 (Classes A++/G)
A++
--
TECHNICAL DATA FOR SIZING THE FLUE
which must in any case satisfy the requirements of this sheet and the installation instructions
CHERIE 9 EVO
Air Tight C
Smoke temperature at smoke outlet
157
°C
Minimum draught
0.001
Pa
Smoke flow rate
5.4
rps
* A calorific value of 4.8 kW/kg was used to calculate consumption.
** The heatable volume is calculated based on the assumption of a heating demand of 33 Kcal/m³ hour.
*** The autonomy may vary in relation to the usage/installation/fuel characteristics and is not contractually binding
nor can it constitute grounds for dispute.
*** Accessories for ducting hot air are available.
The product can work safely even with greater draught.
Excessive draught could cause the product to switch off and/or lower its performance.
NOTE: the smoke outlet diameter does not match the chimney system diameter, which
must be sized accordingly.