9
RECOVERY TANK FILTERS:
VACUUM PRE-FILTER BAG
:
The intake Pre-filter bag has been designed to catch larger
debris before it enters the open area of the waste tank. This
keeps the auto-dump intake filter from clogging too fast.
Locate the filter bag in the waste tank, press the cord
release (circled above in white) and pull back to loosen
the drawstrings. Remove all solids, rinse the bag out
and place back into the tank. Tighten the cord release.
Always remove the bag by loosening the cord, do not
pull the elbow out. Check and clean bag during and after
every job.
AUTO-DUMP INTAKE FILTER:
The auto-dump filter is located next to the vacuum
intake stand pipe. The filter can be removed by turning
counter-clockwise. Turn Clockwise to re-tighten. Check
and clean filter during and after every job.
VACUUM INTAKE FILTER AND VACUUM
SHUT OFF:
The vacuum intake filter houses the float ball which is in
place to shut off airflow to the vacuum motor when there
is too much fluid in the waste tank. This function keeps
the vacuum motor from taking in fluids and getting
damaged. Under normal operating conditions the mesh
screen on the air filter should not get dirty. A dirty filter
is a sign of over-filling or not using defoamer. To remove
the filter cage, Pull down on the filter, in a pivoting mo-
tion. Clean as needed. Firmly press it back into place. If
there is minor build up, you may use a towel to wipe off
the surface of the filter.
NOTE: Daily cleaning filters, are essential to preserving
the proper function of the pump out feature. It is up to
the operator to determine a proper cleaning schedule as
workloads differ from job to job. It is advisable to inspect
the filters throughout each job to gauge what an appro-
priate cleaning schedule would be.