MMU-16LE
SmartMonitor
Operations Manual
Eberle Design Inc.
Page 44
Pin
Function
I/O
h
Channel 3 Yellow
[I]
I
Channel 15 Green
[I]
j
Channel 2 Yellow
[I]
k
Channel 1 Yellow
[I]
m
Controller Voltage Monitor
[I]
n
+24V Monitor Inhibit
[I]
p
Output Relay 1 Closed (Stop Time)
(Opens when fault occurs)
[O]
q
Output Relay 2 Open (FTR Drive)
(Closes when fault occurs)
[O]
r
Channel 12 Walk (Type 12 only)
[I]
s
Channel 11 Walk (Type 12 only)
[I]
t
Channel 9 Walk (Type 12 only)
[I]
u
Channel 16 Yellow
[I]
v
Channel 15 Yellow
[I]
w
Channel 13 Yellow
[I]
x
Channel 4 Yellow
[I]
y
Channel 14 Green
[I]
z
Channel 13 Green
[I]
10.2.2 TYPE 16 CONNECTOR MS-B PIN TERMINATIONS
Pin
Function
I/O
A
AC Line
[I]
B
Start-Delay Relay Common
[I]
C
Start-Delay Relay Open
(Closes during Start Delay period)
[O]
D
Channel 12 Red
[I]
E
Channel 11 Red
[I]
F
Channel 9 Red
[I]
G
Channel 8 Red
[I]
H
Channel 7 Red
[I]
J
Channel 6 Red
[I]
K
Channel 5 Red
[I]
L
Channel 4 Red
[I]
M
Channel 2 Red
[I]
N
Channel 1 Red
[I]
P
Spare 1
[-]
R
+24V Monitor II
[I]
S
External Watchdog (Spare 2)
[-]
T
Channel 13 Red
[I]
U
Start-Delay Relay Closed
(Open during Start Delay period)
[O]
V
Channel 10 Red
[I]
W
Channel 14 Red
[I]
X
Channel 15 Red
[I]
Y
Channel 16 Red
[I]
Z
Channel 3 Red
[I]
a
Red Enable
[I]
b
Spare 3
[-]
c
Local Flash Status
[I]