If the twisted-pair cable is to join two ports and either both ports are
labeled with an “X” (MDI-X) or neither port is labeled with an “X”
(MDI), a crossover must be implemented in the wiring. (When
auto-negotiation is enabled for any RJ-45 port on this switch, you can use
either straight-through or crossover cable to connect to any device type.)
You must connect all four wire pairs as shown in the following diagram to
support Gigabit Ethernet connections.
Figure B-3 Crossover Wiring
White/Orange Stripe
Orange
White/Green Stripe
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
10/100BASE-TX Crossover Cable
E
nd
A
E
nd B
Green
Blue
White/Blue Stripe
Brown
White/Brown Stripe