10
Liquid Propane (LP) Installation and Requirements:
Side burners operated with LP fuel must be installed with the supplied LP regulator.
EdgeStar LP side burners are designed to be used with a standard 20 lb. Department of
Transportation (DOT) approved LP tank. No tanks larger than 20 lbs. are to be used.
The tank must be marked in accordance with the latest DOT specification for LP gas
tanks:
Specifications for LP gas Cylinders
(DOT CFR49).
LP tanks must come with a protective collar to guard the cylinder threads.
The standard fitting connection for LP tanks is 3/8”.
LP tanks must be filled by a qualified professional and must not ever be overfilled.
An Overfill Prevention Device (ODP) must be used at all times.
This side burner is to be used in residential applications only. Propane tank
pressure should be 11 inches water column.
When using an LP tank, pressure relief devices and valves shall be in direct contact with
the vapor space of the cylinder when in normal use.
LP tanks must always be secured and anchored in an upright position when in use. An
LP tank base and retention bolt must be used (not included).
The LP tank base should be fastened securely to the bottom of the island / cabinet using a
combination of bolts, washers, and nuts.
Ensure that a minimum of 2” of clearance is
maintained between the floor and the LP cylinder. Once the LP tank base is secured, place the
primary LP tank in place and tighten the retention bolt until the tank is snug.