background image

Содержание AP410HS

Страница 1: ......

Страница 2: ...ndicators 11 Buttons 12 Remote control 12 Setting up the remote control 12 Notes 12 Caution 13 Remote control functions 13 Regulating airflow direction 15 Manual drainage 16 Drain parts 16 Draining with the drain tray 16 Direct drainage 17 Maintenance 17 Notes 17 Cleaning the Exterior 17 Cleaning the condenser coils 17 Prefilter and charcoal filter 17 Notes 17 Installing the charcoal filter 18 Cle...

Страница 3: ...t so the more people in a room the more cooling capacity is required 8 Set the portable air conditioner to maximum cooling and high speed airflow when you first start it up and then adjust the unit to a comfortable setting Notes The portable air conditioner must be plugged into an appropriate power outlet Refer to the rating label on the back of the unit for more information The portable air condi...

Страница 4: ... h x 21 w x 17 3 8 d Please note that maximum room sizes are under ideal conditions Actual cooling heating areas may vary Safety precautions 1 Transport the portable air conditioner in an upright position only If the unit is tipped over make sure it stands upright for at least 3 hours prior to turning it on 2 Always place the unit on a level surface 3 In order to cool the hot air from the exhaust ...

Страница 5: ...e of flammable substances or vapors such as alcohol insecticides gas etc 18 Do not use the plug to start or stop the unit 19 Do not yank on the electric cord or place it near a source of heat If the electric cord is damaged it must be replaced by an authorized service agent 20 Always use the control panel to start or stop the portable air conditioner 21 Always allow for air flow around the portabl...

Страница 6: ...ront view 1 Control panel 2 Adjustable louvers 3 Carry handles 4 Caster wheels Rear view 1 Air inlet 2 Exhaust port 3 Power cord hooks 4 Caster wheels 5 Drain plug a plastic drain cap covers a rubber stopper 5 ...

Страница 7: ...ssories Owner s manual and warranty card Drain hose Exhaust hose Rectangular vent connector Round adapter Drain tray Carbon filter Cap for round adapter Plastic window kit and screws Remote and batteries 6 ...

Страница 8: ...y the exhaust hose must be mounted to the back of the unit 1 Make sure the rectangular vent connector is fitted to one end of the exhaust hose and fit the round adapter to the other end 2 Insert the rectangular vent connector into the exhaust port on the back of the unit 7 ...

Страница 9: ...it to the appropriate size 2 Once you have properly sized the window kit for the window close the window tightly onto the window kit You may need to use screws to hold the window kit in place 3 Position the portable air conditioner near the window extend the exhaust hose as far as you need to and place the end of the exhaust hose which is in the round adapter into the hole in the window kit 4 Matc...

Страница 10: ...dapter into the hole from inside the room and mark the screw hole positions on the wall 3 Remove the round adapter from the wall and drill four screw holes in the positions marked 4 Replace the round adapter into the wall and screw it into place 5 Move the portable air conditioner into place near the wall and insert the exhaust hose into the round adapter Twist the exhaust hose into the adapter in...

Страница 11: ...Try to prevent any kinks or bends in the exhaust hose Kinks or bends may trap exhaust air which can radiate heat into the room or potentially cause the portable air conditioner to shut itself off 3 The exhaust hose supplied with the portable air conditioner has been specifically designed for this air conditioner Do not lengthen the hose or replace it with any other hose 10 ...

Страница 12: ... F If the ambient temperature is above 73 F the unit will operate in cooling mode If the ambient temperature is equal to or below 73 F the unit will operate in either Fan mode if the unit does not have a heating function or in Heating mode if the unit has a heating function 6 COOL Cooling Mode This light is lit when the Cooling mode is operating 7 DRY Dehumidifier Mode This light is lit when the D...

Страница 13: ... to turn the unit on or off To turn the unit on using the timer make sure the unit is off Press the TIMER button until the desired number of hours appears in the LED display After the number of hours you selected elapses the unit will turn on To turn the unit off using the timer make sure the unit is on and operating as you want it to Press the TIMER button until the desired number of hours appear...

Страница 14: ...des of the portable air conditioner 3 Temperature up and down button The part of the button increases the thermostat s temperature setting The part of the button decreases the thermostat s temperature setting These adjustments are only used in the Cooling mode or Heating mode if applicable 4 Fan speed selection button This button adjusts the fan speed between the high and low settings 5 Sleep func...

Страница 15: ...ioner must be on Press the Off timer button once Press the Hour button several times until your desired number of hours appears in the remote control Press the Off timer button again to set the portable air conditioner to turn on in that number of hours 8 Power button This button turns the air conditioner on or off 9 Hour button for on off timer As noted above this button adjusts the number of hou...

Страница 16: ... the louvers on this portable air conditioner can be adjusted up and down and from right to left To adjust the horizontal louvers gently move them up or down as desired To adjust the vertical louvers move the handle at the bottom of the louvers 15 ...

Страница 17: ...s the air conditioner to turn off to avoid overflowing the internal reservoir The portable air conditioner will begin beeping and the Run light will begin blinking and or the display will show the E7 code Drain the unit to return to normal operation Drain parts 1 Drain there is a rubber plug inside this hole 2 Drain cap 3 Drain hose 4 Drain tray Draining with the drain tray 1 Make sure the unit is...

Страница 18: ...air intake on the side of the unit This will help clean household dust out of the condenser coils and allow the unit to run as efficiently as possible Prefilter and charcoal filter Notes To keep dust from clogging the unit never use the portable air conditioner without the filter The prefilter on the back of the unit collects dust contained in the air It must be cleaned periodically to keep the po...

Страница 19: ...prefilter 3 If the prefilter needs more thorough cleaning remove the charcoal filter follow the instructions for Installing the charcoal filter but remove the charcoal filter instead 4 Scrub the prefilter gently in warm water Do not use water warmer than 104 or soapy water 5 Allow the prefilter to dry completely 6 Reinstall the charcoal filter into the filter frame 7 Replace the filter frame into ...

Страница 20: ...he unit is too close to a wall or some other obstacle The unit should be at least 20 away from walls and other obstacles Move the unit The unit is covered The unit will overheat if the air intake or exhaust ports are obstructed Remove the obstruction The Timer off function was activated Press the power button to turn the unit back on The air conditioner starts and then cuts out The room temperatur...

Страница 21: ...s on a level surface The heater light is blinking and the heater will not turn on The unit is still set in air conditioner mode Unplug the unit wait 30 seconds and plug the unit back in Then select the heater function The heater light is blinking but the heater is working The unit is warming up before starting full heat mode Allow the unit to run at least 2 minutes and the light will stop blinking...

Страница 22: ...eplacement of parts designed to be replaced e g filters etc This warranty does not cover service trips to deliver pick up repair or install the product or to instruct in proper usage of the product Damages or operating problems resulting from abuse operation outside environmental specifications uses contrary to instructions provided in the owner s manual accidents vermin fire flood improper instal...

Страница 23: ... mishandling or improper packaging Do not return defective product to the place of purchase THIS WARRANTY IS IN LIEU OF ANY OTHER WARRANTY EXPRESS OR IMPLIED INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE TO THE EXTENT ANY IMPLIED WARRANTY IS REQUIRED BY LAW IT IS LIMITED IN DURATION TO THE EXPRESS WARRANTY PERIOD ABOVE NEITHER THE MANUFACTURER NOR...

Страница 24: ......

Отзывы: