                              Instructions For Use of Your  

              

PT50A Industrial, PT50B & PT50C Sharp 

 

                                             Edge Sharpness Tester

  

                                                                      manufactured by  

                                     

                                   

 

 

Pictured PT50B 

 

Thank you for purchasing a PT50 Series Sharp 

. From now on you will know with precision how sharp 

the edges on your best knives, scissors, woodworking tools and industrial cutting edges  really are.  

Always use caution when handling sharp edges and protective gloves are always a safe bet! 

Содержание PT50A Industrial

Страница 1: ... by Pictured PT50B Thank you for purchasing a PT50 Series Sharp From now on you will know with precision how sharp the edges on your best knives scissors woodworking tools and industrial cutting edges really are Always use caution when handling sharp edges and protective gloves are always a safe bet ...

Страница 2: ...asurement simply multiply the test clip result by 1 2 If the test media tension is relieved in the test clip by working one leg of the clip forward and then back test clips match BESS scores perfectly It is this de tensioning process and the more limited range of test clips that are the subjects of continued discussions with BESSU Test Clips are tensioned to meet the needs of our medical and test ...

Страница 3: ... world for measuring all sorts of edges like those used by woodworkers milliners and industry Only the PT50A though is recommended for edges that may frequently exceed 1000 BESS scores and for moderate industrial use Scissors wood turning tools and circular blades are just a few of the different cutting edges that may be measured with your PT50 Series instrument Usually it is just a matter of fixt...

Страница 4: ... refill canisters are available in two packs part TM02 Make a visual inspection and mental note of how the test media is threaded across and around the fixture Here is how you reload the test media after a test has been conducted Note These instructions are written and pictured with the test fixture held in the left hand You may switch this process if you are other handed 1 Loosen both plastic thu...

Страница 5: ...ife Position Right and the other Knife Position Left will allow measurements very close to the tip or point of the knife In either case the knife blade must be seated and remain seated via downward pressure in the fulcrum while the opposite end handle or tip is pushed or pulled down into the test media The fulcrum acts like a hinge or pivot point for the knife blade and affords excellent control a...

Страница 6: ...tioning of the knife as viewed from above during the measurement process Blade vertical fulcrum and test fixture slots aligned and centered Remember Slow and Easy We re not chopping carrots at least not yet but measuring the sharpness of an edge Your downward movement with the knife should be slow and deliberate Try to find a seated position with arms resting on the worktop for greater control and...

Страница 7: ...Email us at edgeonup com with questions we respond ...