Command Line Interface
4-146
4
Command Mode
Normal Exec, Privileged Exec
Command Usage
If no interface is specified, information on all interfaces is displayed.
Example
This example shows the configuration setting for port 24.
Console#show interfaces switchport ethernet 1/24
Broadcast Threshold: Enabled, 64 Kbits/second
Multicast Threshold: Disabled
Unknown-unicast Threshold: Disabled
LACP Status: Disabled
Ingress Rate Limit: Disabled, 1000000 Kbits per second
Egress Rate Limit: Disabled, 1000000 Kbits per second
VLAN Membership Mode: Hybrid
Ingress Rule: Enabled
Acceptable Frame Type: All frames
Native VLAN: 1
Priority for Untagged Traffic: 0
GVRP Status: Disabled
Allowed VLAN: 1(u),4093(t),
Forbidden VLAN:
Private-VLAN Mode: NONE
Private-VLAN host-association: NONE
Private-VLAN Mapping: NONE
Console#
Table 4-3 show interfaces switchport - display description
Field
Description
Broadcast Threshold
Shows if broadcast storm suppression is enabled or disabled; if enabled it also
shows the threshold level (page 4-141).
Multicast Threshold
Shows if multicast storm suppression is enabled or disabled; if enabled it also
shows the threshold level (page 4-141).
Unknown-unicast
Threshold
Shows if unknown unicast storm suppression is enabled or disabled; if enabled
it also shows the threshold level (page 4-141).
LACP Status
Shows if Link Aggregation Control Protocol has been enabled or disabled
(page 4-149).
Ingress Rate Limit
Shows if ingress rate limiting is enabled, and the current rate limit. (page 4-159).
Egress Rate Limit
Shows if egress rate limiting is enabled, and the current rate limit. (page 4-159).
VLAN Membership Mode Indicates membership mode as Trunk or Hybrid (page 4-197).
Ingress Rule
Shows if ingress filtering is enabled or disabled (page 4-198).
Note:
Ingress filtering is always enabled.
Acceptable Frame Type
Shows if acceptable VLAN frames include all types or tagged frames only
(page 4-197).
Native VLAN
Indicates the default Port VLAN ID (page 4-199).
Priority for Untagged
Traffic
Indicates the default priority for untagged frames (page 4-235).
Содержание ES4524M-PoE
Страница 1: ...Powered by Accton Management Guide ES4524M PoE 24 Port Layer 2 4 Gigabit Ethernet Switch with PoE...
Страница 2: ......
Страница 4: ...ES4524M PoE F1 0 0 5 E012008 ST R01 149100037400A...
Страница 22: ...xviii Tables...
Страница 26: ...xxii Figures...
Страница 34: ...Introduction 1 8 1...
Страница 270: ...Configuring the Switch 3 226...
Страница 404: ...Command Line Interface 4 134 4...
Страница 546: ...Software Specifications A 4 A...
Страница 559: ......
Страница 560: ...ES4524M PoE E012008 ST R01 149100037400A...