Chapter 30
| IP Interface Commands
IPv6 Interface
– 873 –
This example displays a brief summary of IPv6 addresses configured on the switch.
Console#show ipv6 interface brief
Interface VLAN IPv6 IPv6 Address
--------------- ---------- ---------- ------------------------------------
VLAN 1 Up Up 2001:db8:0:1:2e0:cff:fe02:fd/64
VLAN 1 Up Up 2001:db8:2222:7272::72/96
VLAN 1 Up Up fe80::269:3ef9:fe19:6779/64
Console#
Related Commands
show ipv6 mtu
This command displays the maximum transmission unit (MTU) cache for
destinations that have returned an ICMP packet-too-big message along with an
acceptable MTU to this switch.
Command Mode
Normal Exec, Privileged Exec
Example
The following example shows the MTU cache for this device:
Console#show ipv6 mtu
MTU Since Destination Address
1400 00:04:21 5000:1::3
1280 00:04:50 FE80::203:A0FF:FED6:141D
Console#
ND advertised
retransmit
interval
The retransmit interval is included in all router advertisements sent out of an
interface so that nodes on the same link use the same time value.
ND reachable
time
The amount of time a remote IPv6 node is considered reachable after a
reachability confirmation event has occurred
ND advertised
reachable time
The reachable time is included in all router advertisements sent out of an
interface so that nodes on the same link use the same time value.
ND advertised
router lifetime
Tells the neighbor receiving this message how long this router should be used as
a default router.
Table 180: show ipv6 interface - display description
(Continued)
Field
Description
Table 181: show ipv6 mtu - display description
*
Field
Description
MTU
Adjusted MTU contained in the ICMP packet-too-big message returned from this
destination, and now used for all traffic sent along this path.
Содержание ECS4120-28F
Страница 36: ...Contents 36...
Страница 38: ...Figures 38...
Страница 46: ...Section I Getting Started 46...
Страница 70: ...Chapter 1 Initial Switch Configuration Setting the System Clock 70...
Страница 86: ...Chapter 2 Using the Command Line Interface CLI Command Groups 86...
Страница 202: ...Chapter 5 SNMP Commands Additional Trap Commands 202...
Страница 210: ...Chapter 6 Remote Monitoring Commands 210...
Страница 216: ...Chapter 7 Flow Sampling Commands 216...
Страница 278: ...Chapter 8 Authentication Commands PPPoE Intermediate Agent 278...
Страница 360: ...Chapter 9 General Security Measures Port based Traffic Segmentation 360...
Страница 384: ...Chapter 10 Access Control Lists ACL Information 384...
Страница 424: ...Chapter 11 Interface Commands Power Savings 424...
Страница 446: ...Chapter 13 Power over Ethernet Commands 446...
Страница 456: ...Chapter 14 Port Mirroring Commands RSPAN Mirroring Commands 456...
Страница 488: ...Chapter 17 UniDirectional Link Detection Commands 488...
Страница 494: ...Chapter 18 Address Table Commands 494...
Страница 554: ...Chapter 20 ERPS Commands 554...
Страница 620: ...Chapter 22 Class of Service Commands Priority Commands Layer 3 and 4 620...
Страница 638: ...Chapter 23 Quality of Service Commands 638...
Страница 772: ...Chapter 25 LLDP Commands 772...
Страница 814: ...Chapter 26 CFM Commands Delay Measure Operations 814...
Страница 826: ...Chapter 27 OAM Commands 826 1 1 00 12 CF 6A 07 F6 000084 Enabled Disabled Enabled Disabled Console...
Страница 836: ...Chapter 28 Domain Name Service Commands 836...
Страница 848: ...Chapter 29 DHCP Commands DHCP Relay Option 82 848...
Страница 902: ...Section III Appendices 902...
Страница 916: ...Glossary 916...
Страница 926: ...CLI Commands 926...
Страница 937: ......
Страница 938: ...E092017 CS R02...