Chapter 5
| SNMP Commands
Additional Trap Commands
– 200 –
process cpu guard
This command sets the CPU utilization high and low watermarks in percentage of
CPU time utilized and the CPU high and low thresholds in the number of packets
being processed per second. Use the
no
form of this command without any
parameters to restore all of the default settings, or with a specific parameter to
restore the default setting for that item.
Syntax
process cpu
guard
[
high-watermark
high-watermark
|
low-watermark
low-watermark |
max-threshold
max-threshold |
min-threshold
min-threshold |
trap
]
high-watermark
- If the percentage of CPU usage time is higher than the
high-watermark,the switch stops packet flow to the CPU (allowing it to
catch up with packets already in the buffer) until usage time falls below the
low watermark.
low-watermark
- If packet flow has been stopped after exceeding the high
watermark, normal flow will be restored after usage falls beneath the low
watermark.
max-threshold
- If the number of packets being processed per second by
the CPU is higher than the maximum threshold, the switch stops packet
flow to the CPU (allowing it to catch up with packets already in the buffer)
until the number of packets being processed falls below the minimum
threshold.
min-threshold
- If packet flow has been stopped after exceeding the
maximum threshold, normal flow will be restored after usage falls beneath
the minimum threshold.
trap
- If traps are enabled, the switch will send an alarm message if CPU
utilization exceeds the high watermark in percentage of CPU usage time or
exceeds the maximum threshold in the number of packets being processed
by the CPU.
Default Setting
Guard Status: Disabled
High Watermark: 90%
Low Watermark: 70%
Maximum Threshold: 500 packets per second
Minimum Threshold: 50 packets per second
Trap Status: Disabled
Command Mode
Global Configuration
Command Usage
◆
Once the high watermark is exceeded, utilization must drop beneath the low
watermark before the alarm is terminated, and then exceed the high
watermark again before another alarm is triggered.
Содержание ECS4120-28F
Страница 36: ...Contents 36...
Страница 38: ...Figures 38...
Страница 46: ...Section I Getting Started 46...
Страница 70: ...Chapter 1 Initial Switch Configuration Setting the System Clock 70...
Страница 86: ...Chapter 2 Using the Command Line Interface CLI Command Groups 86...
Страница 202: ...Chapter 5 SNMP Commands Additional Trap Commands 202...
Страница 210: ...Chapter 6 Remote Monitoring Commands 210...
Страница 216: ...Chapter 7 Flow Sampling Commands 216...
Страница 278: ...Chapter 8 Authentication Commands PPPoE Intermediate Agent 278...
Страница 360: ...Chapter 9 General Security Measures Port based Traffic Segmentation 360...
Страница 384: ...Chapter 10 Access Control Lists ACL Information 384...
Страница 424: ...Chapter 11 Interface Commands Power Savings 424...
Страница 446: ...Chapter 13 Power over Ethernet Commands 446...
Страница 456: ...Chapter 14 Port Mirroring Commands RSPAN Mirroring Commands 456...
Страница 488: ...Chapter 17 UniDirectional Link Detection Commands 488...
Страница 494: ...Chapter 18 Address Table Commands 494...
Страница 554: ...Chapter 20 ERPS Commands 554...
Страница 620: ...Chapter 22 Class of Service Commands Priority Commands Layer 3 and 4 620...
Страница 638: ...Chapter 23 Quality of Service Commands 638...
Страница 772: ...Chapter 25 LLDP Commands 772...
Страница 814: ...Chapter 26 CFM Commands Delay Measure Operations 814...
Страница 826: ...Chapter 27 OAM Commands 826 1 1 00 12 CF 6A 07 F6 000084 Enabled Disabled Enabled Disabled Console...
Страница 836: ...Chapter 28 Domain Name Service Commands 836...
Страница 848: ...Chapter 29 DHCP Commands DHCP Relay Option 82 848...
Страница 902: ...Section III Appendices 902...
Страница 916: ...Glossary 916...
Страница 926: ...CLI Commands 926...
Страница 937: ......
Страница 938: ...E092017 CS R02...