
Chapter 24
| CFM Commands
Link Trace Operations
– 714 –
clear ethernet cfm
linktrace-cache
This command clears link trace messages logged on this device.
Command Mode
Privileged Exec
Example
Console#clear ethernet cfm linktrace-cache
Console#
show ethernet cfm
linktrace-cache
This command displays the contents of the link trace cache.
Command Mode
Privileged Exec
Example
Console#show ethernet cfm linktrace-cache
Hops MA IP / Alias Ingress MAC Ing. Action Relay
Forwarded Egress MAC Egr. Action
---- -------------- ----------------------- ----------------- ----------- -----
2 rd 192.168.0.6 00-12-CF-12-12-2D ingOk Hit
Not Forwarded
Console#
Table 138: show ethernet cfm linktrace-cache - display description
Field
Description
Hops
The number hops taken to reach the target MEP.
MA
Name of the MA to which this device belongs.
IP/Alias
IP address or alias of the target device’s CPU.
Forwarded
Shows whether or not this link trace message was forwarded. A message
is not forwarded if received by the target MEP.
Ingress MAC
MAC address of the ingress port on the target device.
Egress MAC
MAC address of the egress port on the target device.
Ing. Action
Action taken on the ingress port:
IngOk – The target data frame passed through to the MAC Relay Entity.
IngDown – The bridge port’s MAC_Operational parameter is false. This
value could be returned, for example, by an operationally Down MEP that
has another Down MEP at a higher MD level on the same bridge port that
is causing the bridge port’s MAC_Operational parameter to be false.
IngBlocked – The ingress port can be identified, but the target data frame
was not forwarded when received on this port due to active topology
management, i.e., the bridge port is not in the forwarding state.
IngVid – The ingress port is not in the member set of the LTM’s VIDs, and
ingress filtering is enabled, so the target data frame was filtered by ingress
filtering.
Содержание AS5700-54X
Страница 42: ...Contents 42...
Страница 44: ...Figures 44...
Страница 52: ...Tables 52...
Страница 54: ...Section I Getting Started 54...
Страница 80: ...Chapter 1 Initial Switch Configuration Setting the System Clock 80...
Страница 210: ...Chapter 6 Remote Monitoring Commands 210...
Страница 358: ...Chapter 9 Access Control Lists ACL Information 358...
Страница 418: ...Chapter 12 Port Mirroring Commands RSPAN Mirroring Commands 418...
Страница 436: ...Chapter 15 UniDirectional Link Detection Commands 436...
Страница 442: ...Chapter 16 Address Table Commands 442...
Страница 506: ...Chapter 18 VLAN Commands Configuring VXLAN Tunneling 506...
Страница 526: ...Chapter 19 Class of Service Commands Priority Commands Layer 3 and 4 526...
Страница 544: ...Chapter 20 Quality of Service Commands 544...
Страница 652: ...Chapter 22 Multicast Filtering Commands MLD Proxy Routing 652...
Страница 680: ...Chapter 23 LLDP Commands 680...
Страница 722: ...Chapter 24 CFM Commands Delay Measure Operations 722...
Страница 732: ...Chapter 25 Domain Name Service Commands 732...
Страница 790: ...Chapter 27 IP Interface Commands ND Snooping 790...
Страница 1072: ...Section III Appendices 1072...
Страница 1090: ...Glossary 1090 XModem A protocol used to transfer files between devices Data is grouped in 128 byte blocks and error corrected...
Страница 1102: ...List of CLI Commands 1102...
Страница 1115: ......
Страница 1116: ...AS5700 54X AS6700 32X E032016 ST R02 149100000198A...