Chapter 10
| Interface Commands
Transceiver Threshold Configuration
– 384 –
Example
The following example sets alarm thresholds for the transceiver voltage at port 1.
Console(config)interface ethernet 1/1
Console(config-if)#transceiver-threshold voltage low-alarm 4
Console(config-if)#transceiver-threshold voltage high-alarm 2
Console#
show interfaces
transceiver
This command displays identifying information for the specified transceiver,
including connector type and vendor-related parameters, as well as the
temperature, voltage, bias current, transmit power, and receive power.
Syntax
show interfaces transceiver
[
interface
]
interface
ethernet
unit
/
port
unit
- Unit identifier. (Range: 1)
port
- Port number. (Range: 1-32/54)
Default Setting
Shows all SFP interfaces.
Command Mode
Privileged Exec
Command Usage
◆
The switch can display diagnostic information for SFP modules which support
the SFF-8472 Specification for Diagnostic Monitoring Interface for Optical
Transceivers. This information allows administrators to remotely diagnose
problems with optical devices. This feature, referred to as Digital Diagnostic
Monitoring (DDM) in the command display, provides information on
transceiver parameters including temperature, supply voltage, laser bias
current, laser power, received optical power, and related alarm thresholds.
◆
When the measured value of a monitored DDM item meets the condition of a
warning state or an alarm state, an exclamation mark (i.e., “!”) will be added
behind the value of the warning threshold value or alarm threshold value.
◆
This switch does not support the detection of the Rx loss signal of an SFP
transceiver, so the Rx loss status of an SFP transceiver is always treated as
deasserted. The warning/alarm state of a monitored DDM item is therefore not
related to the Rx loss status of an SFP transceiver
Содержание AS5700-54X
Страница 42: ...Contents 42...
Страница 44: ...Figures 44...
Страница 52: ...Tables 52...
Страница 54: ...Section I Getting Started 54...
Страница 80: ...Chapter 1 Initial Switch Configuration Setting the System Clock 80...
Страница 210: ...Chapter 6 Remote Monitoring Commands 210...
Страница 358: ...Chapter 9 Access Control Lists ACL Information 358...
Страница 418: ...Chapter 12 Port Mirroring Commands RSPAN Mirroring Commands 418...
Страница 436: ...Chapter 15 UniDirectional Link Detection Commands 436...
Страница 442: ...Chapter 16 Address Table Commands 442...
Страница 506: ...Chapter 18 VLAN Commands Configuring VXLAN Tunneling 506...
Страница 526: ...Chapter 19 Class of Service Commands Priority Commands Layer 3 and 4 526...
Страница 544: ...Chapter 20 Quality of Service Commands 544...
Страница 652: ...Chapter 22 Multicast Filtering Commands MLD Proxy Routing 652...
Страница 680: ...Chapter 23 LLDP Commands 680...
Страница 722: ...Chapter 24 CFM Commands Delay Measure Operations 722...
Страница 732: ...Chapter 25 Domain Name Service Commands 732...
Страница 790: ...Chapter 27 IP Interface Commands ND Snooping 790...
Страница 1072: ...Section III Appendices 1072...
Страница 1090: ...Glossary 1090 XModem A protocol used to transfer files between devices Data is grouped in 128 byte blocks and error corrected...
Страница 1102: ...List of CLI Commands 1102...
Страница 1115: ......
Страница 1116: ...AS5700 54X AS6700 32X E032016 ST R02 149100000198A...