Chapter 8
| General Security Measures
Network Access (MAC Address Authentication)
– 270 –
Command Usage
◆
When enabled on a port, the authentication process sends a Password
Authentication Protocol (PAP) request to a configured RADIUS server. The user
name and password are both equal to the MAC address being authenticated.
◆
On the RADIUS server, PAP user name and passwords must be configured in the
MAC address format XX-XX-XX-XX-XX-XX (all in upper case).
◆
Authenticated MAC addresses are stored as dynamic entries in the switch
secure MAC address table and are removed when the aging time expires. The
maximum number of secure MAC addresses supported for the switch system is
1024.
◆
Configured static MAC addresses are added to the secure address table when
seen on a switch port. Static addresses are treated as authenticated without
sending a request to a RADIUS server.
◆
MAC authentication, 802.1X, and port security cannot be configured together
on the same port. Only one security mechanism can be applied.
◆
MAC authentication cannot be configured on trunks (i.e., static nor dynamic).
◆
When port status changes to down, all MAC addresses are cleared from the
secure MAC address table. Static VLAN assignments are not restored.
◆
The RADIUS server may optionally return a VLAN identifier list. VLAN identifier
list is carried in the “Tunnel-Private-Group-ID” attribute. The VLAN list can
contain multiple VLAN identifiers in the format “1u,2t,” where “u” indicates
untagged VLAN and “t” tagged VLAN. The “Tunnel-Type” attribute should be
set to “VLAN,” and the “Tunnel-Medium-Type” attribute set to “802.”
Example
Console(config-if)#network-access mode mac-authentication
Console(config-if)#
network-access port-
mac-filter
Use this command to enable the specified MAC address filter. Use the
no
form of
this command to disable the specified MAC address filter.
Syntax
network-access port-mac-filter
filter-id
no network-access port-mac-filter
filter-id
- Specifies a MAC address filter table. (Range: 1-64)
Default Setting
None
Содержание AS5700-54X
Страница 42: ...Contents 42...
Страница 44: ...Figures 44...
Страница 52: ...Tables 52...
Страница 54: ...Section I Getting Started 54...
Страница 80: ...Chapter 1 Initial Switch Configuration Setting the System Clock 80...
Страница 210: ...Chapter 6 Remote Monitoring Commands 210...
Страница 358: ...Chapter 9 Access Control Lists ACL Information 358...
Страница 418: ...Chapter 12 Port Mirroring Commands RSPAN Mirroring Commands 418...
Страница 436: ...Chapter 15 UniDirectional Link Detection Commands 436...
Страница 442: ...Chapter 16 Address Table Commands 442...
Страница 506: ...Chapter 18 VLAN Commands Configuring VXLAN Tunneling 506...
Страница 526: ...Chapter 19 Class of Service Commands Priority Commands Layer 3 and 4 526...
Страница 544: ...Chapter 20 Quality of Service Commands 544...
Страница 652: ...Chapter 22 Multicast Filtering Commands MLD Proxy Routing 652...
Страница 680: ...Chapter 23 LLDP Commands 680...
Страница 722: ...Chapter 24 CFM Commands Delay Measure Operations 722...
Страница 732: ...Chapter 25 Domain Name Service Commands 732...
Страница 790: ...Chapter 27 IP Interface Commands ND Snooping 790...
Страница 1072: ...Section III Appendices 1072...
Страница 1090: ...Glossary 1090 XModem A protocol used to transfer files between devices Data is grouped in 128 byte blocks and error corrected...
Страница 1102: ...List of CLI Commands 1102...
Страница 1115: ......
Страница 1116: ...AS5700 54X AS6700 32X E032016 ST R02 149100000198A...