245503_00 | 10.2021 EDER hydraulic power unit    5 

EN 

Check the engine oil level before each use. 
 
The oil tank of the hydraulic unit is filled with 5 litres of mineral hydraulic oil (HLP ISO 46) 
on delivery. 
 

 
Connect  the  hydraulic  hoses  correctly  before  starting 
the engine. The pressure line is marked with a "

P

" on 

the EDER hydraulic unit.  Make sure that the pressure 
line and  the return hose are connected correctly.  The 
hoses and the hydraulic connections on the power unit 
must be kept clean. 
 
 

 

 
 

 

Incorrectly connected or dirty hydraulic hoses can cause 
damage to the connected unit. 
 
Do not start the engine until both hydraulic hoses are 
connected. 
 

 
 

Maintenance 

Check the operating materials daily before each work operation: 
The engine oil level must be checked with the dipstick on the engine in accordance with the 
operating instructions for the petrol engine and topped up if necessary. The content of the 
hydraulic oil reservoir must be checked by unscrewing the red screw cap of the filler opening 
and topped up at the latest when the minimum oil level is reached or fallen short of. Only 
use mineral hydraulic oil that complies with the following specification: 

HLP ISO 46

 
During use, pay attention to unusual operating noises and possibly leaking or damaged fluid 
lines and screw connections. If a defect is suspected, you must take the unit out of operation 
and eliminate the cause or have it checked and repaired at a specialist workshop to avoid 
further consequential damage. 
Clean dirty components regularly. 
 
Only original spare parts from EDER Maschinenbau GmbH or the engine manufacturer are 
to be used as replacements for defective parts!  
 

Recycling

 

The  EDER  splitting  unit  contains  oils/greases  and  must  be  disposed  of  by  a  recycling 
company.  
 

Содержание EHA150

Страница 1: ...Original 245503_00 10 2021 Operating instructions EDER hydraulic unit Schweigerstraße 6 38302 Wolfenbüttel Germany ...

Страница 2: ...onformity 7 Dear customer thank you for choosing a quality product from Eder Maschinenbau GmbH For correct use and to prevent accidents please read the operating instructions carefully Ignoring the safety instructions can lead to serious injuries Status 10 2021 Eder Mechanical Engineering GmbH Schweigerstrasse 6 38302 Wolfenbüttel www eder maschinenbau de info eder maschinenbau de Phone 49 5331 90...

Страница 3: ...ohibited Technical data 4 stroke drive engine Honda GX200 4 stroke Honda GX200 Net power 4 3 kW 5 8 hp Rated speed 3600 min 1 Length 670 mm Wide 390 mm Height 430 mm Delivery pump volume 3 6 cm revolution Hydraulic oil tank capacity 5l Weight without petrol 30 kg Oil stream 14l min 1 Oil pressure Max 150 bar For detailed technical data on the engine and its maintenance please read and observe the ...

Страница 4: ... 4 The EDER hydraulic unit may only be used in sufficiently good lighting conditions 5 The operationally safe condition of the unit must always be checked before starting work 6 The EDER hydraulic unit must not be used if damage to the unit or to the hydraulic system and hoses has been detected If leakage is suspected do not feel the hydraulic unit and hoses with bare hands An oil jet escaping at ...

Страница 5: ...n the engine in accordance with the operating instructions for the petrol engine and topped up if necessary The content of the hydraulic oil reservoir must be checked by unscrewing the red screw cap of the filler opening and topped up at the latest when the minimum oil level is reached or fallen short of Only use mineral hydraulic oil that complies with the following specification HLP ISO 46 Durin...

Страница 6: ...is 24 months and for commercial use 12 months First of all the seller must always be given the opportunity for subsequent performance within a reasonable period of time No warranty The manufacturer does not provide any warranty for Parts that are subject to natural wear and tear Non compliance with the operating instructions and lack of or incorrect care Consequences of improper maintenance and se...

Страница 7: ...ct EDER splitting unit model EHG1 serial number starting from 0001 MM YY to which this declaration refers complies with the following standards and normative documents Directive 2006 42 EC of the European Parliament and of the Council of 17 May 2006 on machinery and amending Directive 95 16 EC recast DIN EN 982 2009 06 Safety of machinery Safety requirements for fluid power systems and their compo...

Страница 8: ......

Отзывы: