LED 

 

When  the  battery  voltage  is  low,  the  AMBER  LED  will  flash  every  30 
sec.   

 

While  the  Carbon  Monoxide  Detector  is  transmitting  the  signal,  the 
RED LED will perform a long flash with “Ding Dong” melody. 

 

While the batteries are inserted and the Carbon Monoxide Detector is 
in  warming  period,  the  GREEN  LED  will  flashes  once  every  seconds 
for 2 ~ 10 minutes.   

 

While the sensor is taking CO concentration reading from the air, the GREEN LED will flashes 
once every 30 seconds. 

 

Installation Procedures 

Step 1  Insert  the  3  “AA”  batteries  into  the  battery  compartment  taking  care  that  the  connection 

respects correct polarity showing on the battery holder. 

Step 2  While the  3  batteries  are  inserted;  the  HA2000CO  will  sound  a  “Ding-Dong” melody  and 

the GREEN LED stays on. 

Step 3  The  warming  up  process  takes  between  2~10  minutes.  The  GREEN  LED  flashes  every 

second indicates that the warming up process is taking place. After the warming up period 
is complete, the GREEN LED then flashes once every 30 seconds.   

<NOTE>

 

 

While  it  is  under the  warming  up  period,  if the Test  Button  has  been  pressed,  it  will  send a 
test code to the Control Panel and the RED LED will perform a long flash and “Ding Dong” 
melody. After the transmitting process finishes, the GREEN comes back on.   

 

If the Test Button has been pressed during the Stand-by mode, then the HA2000CO will be 
transmitting a Test signal to report to the Control Panel. This is performed by a long flash of 
RED LED and “Ding Dong” melody. 

Step 4   Put the Control Panel into “/-“ menu and then select “Add Device” menu. 

Step 5  Press the CO detector’s test button on the front cover. 

Step 6  Refer  to  the  operation  manual  of  your  control  panel  under  the  section  of  “Device  +/-“  to 

complete the learn-in process. 

Step 7  After  the  detector  is  learnt-in,  put  the  Control  Panel  into  “Walk  Test”  mode,  hold the  CO 

detector in the desired location, and press the Test button to confirm this location is within 
signal range of the Control Panel. 

Step 8  When you are satisfied that the CO detector work in the chosen location, you can proceed 

with installation. 

 

While  the  HA2000CO  is  alarming,  with  the  press  of the Test  Button  will  result  to  ‘cancel’  the 
alarm  signal  and  terminate  the  reporting  process.  This  is  performed  by  a  long  flash  of  RED 
LED and “Ding Dong” melody. 

 

  The alarm will be activated by: 

<NOTE> 

 

When  the  CO  sensor  detected  any 
unusual  CO  concentration  in  the  air  that 

CO concentration 

level 

Time taken before 

alarming 

30 ppm 

120 minutes 

50 ppm 

50 minutes

 

100 ppm 

10 minutes

 

300 ppm 

2 minutes

 

500 ppm 

30 seconds

 