Edelbrock Nitrous Systems
Standard Bottle Valve With 10-lb. Bottle Siphon Tube
Catalog #72310
INSTALLATION INSTRUCTIONS
Please study these instructions carefully before installing your new standard bottle valve and 10-lb. bottle
siphon tube.
If you have any questions or problems, please contact our
Technical Hotline at: 1-800-416-8628
from
7 am - 5 pm, Monday through Friday, Pacific Standard Time or e-mail us at
Description:
The standard bottle valve with 10-lb. bottle siphon tube kit consists of a replacement bottle valve for use
on any brand 10-lb. nitrous bottle and .500” high flow siphon tube.
Edelbrock Corporation
2700 California St.
Torrance, CA 90503
Tech Line: (800) 416-8628
E-Mail: [email protected]
A
B
C
KIT CONTENTS
Quantity
Description
1
“Bottle Valve, 660 High Flow”
(A)
1
“10-lb. Bottle Siphon Tube”
(B)
1
“Bottle Valve, O-Ring”
(C)
WARNING!!!
ONLY USE wide temperature range (-40°F to 400°F), fuel and oxidizer
resistant synthetic grease on the bottle valve O-Ring. Non-compatible
greases may cause the O-ring to swell resulting in improper seal and
premature wear. Edelbrock recommends the use of Aerospace
Lubricants, Inc., Tribolube-16 which meets the qualification requirements
of Mil-G-27617D Types 2 & 3.
ASSEMBLY
Lubricate the bottle
valve o-ring with the
r e c o m m e n d e d
lubricant.
Apply a small amount of
red Loctite to siphon
tube threads and install
on valve.
Make sure inlet of
siphon tube is aligned
with the outlet of valve.
Install the bottle valve
and siphon tube
assembly on bottle.
Torque valve to 110-
ft/lbs.
Cut-away view of
properly installed valve
and siphon tube in a
10-lb. bottle.