Edelbrock 72176 Скачать руководство пользователя страница 1

Catalog #72176, 72178
Rev. 2/08 - AJ/mc

©2008 Edelbrock Corporation

Brochure No. 63-0161

Edelbrock Nitrous Systems

-4AN/-6AN Purge Valve Kit

Catalog #s 72176 & 72178

INSTALLATION INSTRUCTION

Please study these instructions carefully before installing your new Purge Valve Kit.

If you have any questions, please

contact our 

Technical Hotline at: (800) 416-8628

from 7 am - 5 pm, Monday through Friday, Pacific Standard Time or e-mail us

at 

[email protected].

DESCRIPTION:

The -4AN/-6AN Purge Valve Kit is design to vent gaseous nitrous to the atmosphere to fill the nitrous feed line with

liquid nitrous for a better nitrous charge when the nitrous system is in use. Be sure the nitrous purge line is mounted on the vehicle
so the spray direction is not pointed in a direction which could fill the passenger compartment with nitrous oxide.

INSTALLATION INSTRUCTIONS

1.

Be sure the nitrous bottle is turned to the “off” position.

2.

Relieve any pressure in the line by slowly loosening the main line fitting
from the bottle.

IMPORTANT NOTE:

Nitrous Oxide can be lethal and must be

handled with extreme caution.  Be sure you are located in a well-
ventilated area.  Remove your hands from the fitting while the
nitrous oxide is venting and move away to keep from breathing
the escaping nitrous.

3.

Install the 1/8”NPT x 1/8”NPT filter fitting adapter onto the purge valve
adapter. Use only liquid Teflon® on this connection.

4.

Install the nitrous purge solenoid onto the 1/8”NPT x 1/8”NPT adapter.
Use only liquid Teflon® on this connection.

5.

Install the compression fitting onto the nitrous purge solenoid. Use only
liquid Teflon® on the pipe section of this fitting connection.

6.

Install the purge valve adapter fitting onto the nitrous solenoid fitting. Do not use any chemical thread sealant on either of these
fittings. Ensure that the purge valve adapter will not interfere with any other engine system or component.

7.

Connect the main nitrous feed line to the purge valve adapter. Again, do not use any
chemical thread sealant on either of these fittings.

8.

Attach the 1/8” poly line into the ferrule fitting on the nitrous purge solenoid. Bend
and conform the plastic tube to vent the nitrous purge towards the base of the
windshield, out and away from the engine compartment. Never configure this vent
tube to point in the direction of people. Securely attach the end of the vent tube to
the vehicle. This is a point of high-pressure gas escaping into the atmosphere and
the tube could cause injury, if not properly secured.

9.

Mount the nitrous purge solenoid on/off push button switch in the passenger
compartment of the vehicle. Place it in a convenient and visible location.

10. Connect one solenoid wire (it does not matter which one) to a good ground on the

chassis.

11. Connect the remaining solenoid wire to the nitrous purge solenoid on/off push button

switch.

12. Connect the remaining lead from the nitrous purge solenoid on/off button switch to

the “ignition-switched” 12-volt source of the nitrous system. This will ensure that
your system can only be purged when the arming switch is in the “on” position.

13. Re-connect the nitrous feed line to the nitrous bottle. Check the system for leaks and

test your purge valve for proper operation and purge spray direction.

Edelbrock Corporation • 2700 California St. • Torrance, CA 90503

Tech-Line: 800-416-8628 • E-Mail: [email protected]

Отзывы: