background image

52

Appendix A: Accessories

Protective Caps

Protective Caps

If you need to tackle challenging inspection environments where dust or nuclear 

contamination is present, you need protective caps to cover the Ectane

®

 2’s 

connectors. All the connectors have specific protective caps. Contact your Eddyfi 

representative for more information about pricing and availability.

Adapters and Connectors

The Ectane 2 connectors were chosen to match the most common connectors in use 

today. You could, however, have specific needs outside the connectors supplied 

with the Ectane 2. Eddyfi offers a comprehensive array of adapters and specialty 

connectors to suit your needs. Contact your Eddyfi representative for more 

information about pricing and availability.

Battery Charger and Batteries

The Ectane 2 comes with batteries. Depending on your work environment and 

your workload, however, you could have a need for more and the optional battery 

charger. Contact your Eddyfi representative for more information about pricing 

and availability.

Remote Control

The Ectane 2 can be operated through an optional remote control. Contact your 

Eddyfi representative for more information about pricing and availability.

Содержание Ectane 2

Страница 1: ...User s Guide...

Страница 2: ...The instrument must only be connected to a power source corresponding to the type indicated on the rating plate If the equipment is used in a manner not specified by Eddyfi NDT Inc the protection prov...

Страница 3: ...C This directive prohibits the use of lead mercury cadmium hexavalent chrome polybrominated biphenyl PBB or polybrominated diphenyl ether PBDE in certain classes of electrical and electronic units as...

Страница 4: ...ed parenthetical information that is useful but not essential WARNING The Warning sign indicates a hazard It calls attention to a procedure practice or the like which if not correctly performed or adh...

Страница 5: ...asis on a specific word or phrase i e This options should never be selected Bold A bold typeface is used to indicate the name of a menu item or a named user interface element i e the File menu the Opt...

Страница 6: ...the Instrument 11 Setting Up the Instrument 12 Connection Configurations 13 Starting the Instrument 15 Understanding Indicators 15 Power Indicators 15 Battery Indicators 16 Connection Indicators 19 M...

Страница 7: ...43 Eddy Current Testing ECT 43 Eddy Current Array ECA 44 Remote Near Field Testing RFT NFT 44 Magnetic Flux Leakage MFL 45 Internal Rotary Inspection System IRIS 45 Maintenance Troubleshooting 47 Pre...

Страница 8: ...Introducing the Ectane 2...

Страница 9: ...ltrasound technology Battery power and backup for flexibility and 100 uptime Plug and play connectivity no more BootP Standard connectors The Ectane 2 is controlled by a computer running Microsoft Win...

Страница 10: ...IRIS capabilities Available configurations are Ectane 2 E Ectane 2 E64 Ectane 2 E128 Ectane 2 E256 Ectane 2 I Ectane 2 ERNM Ectane 2 ERNMI Ectane 2 E64RNM Ectane 2 E64RNMI Ectane 2 E128RNM Ectane 2 E1...

Страница 11: ...4 Chapter 1 Introducing the Ectane 2 Presentation Figure 1 Ectane 2 E Figure 2 Ectane 2 E64 and E128...

Страница 12: ...5 Presentation Figure 3 Ectane 2 E256 Figure 4 Ectane 2 I...

Страница 13: ...6 Chapter 1 Introducing the Ectane 2 Presentation Figure 5 Ectane 2 ERNM Figure 6 Ectane 2 ERNMI...

Страница 14: ...7 Presentation Figure 7 Ectane 2 E64RNM and E128RNM Figure 8 Ectane 2 E64RNMI and E128RNMI...

Страница 15: ...ehind the instrument you will find the ground connector used to ground the Ectane 2 when the situation requires it Figure 9 Ground connector The ground connector is a simple screw that you remove to i...

Страница 16: ...he batteries are accessible from a side access panel as shown below Figure 10 Battery compartment Important The firmware backup button is used in cases where the Ectane 2 s original firmware becomes c...

Страница 17: ...Preparing the Instrument...

Страница 18: ...n the instrument away from heat sources This ensures proper heat dissipation while the instrument is in use WARNING Never use the instrument when it is upside down batteries on top This position preve...

Страница 19: ...2 allows various test configurations The following figures illustrate some of these configurations Figure 1 Typical configuration 1 Ectane 2 with SmartMUX Figure 2 Typical configuration 2 Ectane 2 wi...

Страница 20: ...14 Chapter 2 Preparing the Instrument Setting Up the Instrument Figure 3 Typical configuration 3 Ectane 2 with bobbin probe...

Страница 21: ...lights up orange and all the indicators on the front panel of the instrument light up Note If you want to use the batteries simply press the power button Understanding Indicators There are various in...

Страница 22: ...ators Figure 4 Power indicators Battery Indicators Each battery has its own charge level indicator and charging status indicator Figure 5 Battery B indicators Power button indicator External power ind...

Страница 23: ...indicators light and blink depending on each battery s charge level as explained below LED 1 from bottom is blinking Charge is less than 10 LED 1 is solid Charge is over 10 LED 2 is solid Charge is o...

Страница 24: ...Ectane 2 shuts down because of low battery power or overheating the instrument automatically starts again once the shutdown condition clears Off When the following two conditions are present no extern...

Страница 25: ...indicator can be in one of three states Orange is solid Gigabit Ethernet communication is established Green is solid 100 Mbps Ethernet communication is established Off 10 Mbps Ethernet communication...

Страница 26: ...Managing Batteries...

Страница 27: ...teries which is important to maximize their useful life and to ensure accurate readings for the battery charger indicator in Magnifi Eddyfi recommends calibrating batteries at least every six months f...

Страница 28: ...Place the batteries into either battery bay making sure that their 5 way connectors are fully seated The LEDs in the status window display status information and the charger automatically begins char...

Страница 29: ...n each screw of the battery compartment door counterclockwise a quarter of a turn The battery compartment door pops out Figure 2 Opening the battery compartment door Note The screws are designed to st...

Страница 30: ...acquisition etc is lost Battery Indicators Each battery has its own charge level indicator and charging status indicator For details about which charge level indicator relates to what battery see Bat...

Страница 31: ...shuts down because of low battery power or overheating the instrument automatically starts again once the shutdown condition clears Off When the following two conditions are met No external power is p...

Страница 32: ...Connector References...

Страница 33: ...Amphenol 58 570127 41S Eddyfi NDT Inc MACN4012 Suggested cable connector ITT Cannon KPT06B20 41P or Amphenol PT06J 20 41P Eddyfi NDT Inc MACN0005 Table 1 EXTENDED ET connector pinout Pin I O Signal De...

Страница 34: ...grounded Clock signal if pin J is grounded U Output MUX 1 CLK Multiplexing signal output bit 1 if pin J is not grounded Clock signal if pin J is grounded V Output MUX 2 12 5 V supply Multiplexing sig...

Страница 35: ...input of input amplifier 5 j Input In5 input Negative input of input amplifier 5 k Input In6 input Positive input of input amplifier 6 m Input In6 input Negative input of input amplifier 6 n Input In7...

Страница 36: ...female shell 14 connector Manufacturer number Amphenol 58 570124 19S or Souriau 851 02E1419S50A7 Eddyfi NDT Inc MACN4015 Suggested cable connector ITT Cannon KPT06A14 19P027 or Amphenol PT06J 14 19P...

Страница 37: ...RFT input 2 Positive MFL input 2 L Input RFT_IN 2 MFL_IN 2 Negative RFT input 2 Negative MFL input 2 M Input RFT_IN 1 MFL_IN 1 Positive RFT input 1 Positive MFL input 1 N Input RFT_IN 1 MFL_IN 1 Nega...

Страница 38: ...on probes Figure 3 ECT BOBBIN connector Description 4 pin female shell 14 connector Manufacturer number Amphenol ACS02A 14S 2S 472 Eddyfi NDT Inc MACN4020 Suggested cable connector Amphenol 97 3106A 1...

Страница 39: ...MACN4014 Suggested cable connector ITT Cannon KPT06B14 18P or Amphenol PT06J 14 18P Eddyfi NDT Inc MACN0011 Table 4 ENCODERS connector pinout Pin I O Signal Description A TTL Input B1 Phase B axis 1...

Страница 40: ...r automatic acquisition sequence control M TTL Input CLKACQ Receives signal to trigger acquisition with probe position along the scanning axis N NC No connection Reserved P TTL Input B2 Phase B axis 2...

Страница 41: ...NT ARRAY These connectors are specific and designed by Eddyfi For details about the Eddyfi 160 pin connectors contact Eddyfi directly at info eddyfi com Description BNC Adapter bulkhead 50 Manufacture...

Страница 42: ...ast a category 5e shielded Ethernet cable Description RJ45 female connector Manufacturer number PEI Genesis Amphenol RJF22B00SCC Eddyfi NDT Inc MACN4016 Table 6 Ethernet connector pinout Pin I O Signa...

Страница 43: ...Specifications...

Страница 44: ...ommends waiting until the end of the warm up period before balancing probes or performing acquisitions 15 minutes Workstation link Ethernet 1000BASE T Transfer rate on Ethernet cable 1 Gbps Power conf...

Страница 45: ...the instrument becomes inactive for work purposes until the condition that initiated the power safe mode is corrected 0 C to 45 C 32 F to 113 F Storage temperature 20 C to 60 C 4 F to 140 F Relative...

Страница 46: ...rive for Rotating Probes Current Source for Saturation Probes Voltage 0 24 V Maximum peak output current 2 A Maximum continuous output current 1 A Maximum continuous power 10 W Range 0 1 A Maximum out...

Страница 47: ...Hz 10 MHz Generators Coil drivers 2 Generator output Coil drive Up to 20 V peak to peak Injection modes Multiplexed simultaneous continuous Receiver gain 41 dB range 23 64 dB Data resolution 16 bits A...

Страница 48: ...UX integrated universal and programmable Connector typea a The Ectane 2 uses an ID device found in Eddyfi probes This ID device contains information that helps set up acquisitions and confirm compatib...

Страница 49: ...41 pin EXTENDED ET connector Number of UT channels 1 pulse echo Transducer frequency 5 MHz 10 MHz 15 MHz or 20 MHz Pulsing rate Up to 30 kHz Pulser voltage 75 200 V 25 V steps Pulse width Automatical...

Страница 50: ...Maintenance Troubleshooting...

Страница 51: ...al surfaces i e casing and front panel can be cleaned when necessary This section explains the procedure to appropriately clean the instrument To clean the instrument 1 Make sure that the instrument i...

Страница 52: ...ional external charger and then pressing the recalibrate button See Managing Batteries on page 21 Eddyfi recommends calibrating your batteries at least once every six months Troubleshooting To trouble...

Страница 53: ...Accessories...

Страница 54: ...ve specific needs outside the connectors supplied with the Ectane 2 Eddyfi offers a comprehensive array of adapters and specialty connectors to suit your needs Contact your Eddyfi representative for m...

Страница 55: ...Warranty Trademarks Copyrights...

Страница 56: ...lting from possession use improper installation accident service modification or malfunction of the product including without limitation damages for loss of business profits business interruption loss...

Страница 57: ...translation in other languages and formats Eddyfi NDT Inc 2014 This document was prepared with particular attention to usage to ensure the accuracy of the information it contains It corresponds to the...

Страница 58: ...logos are trademarks or registered trademarks of Eddyfi NDT Inc Eddyfi reserves itself the right to change product offerings and specifications without notice 2013 08 11 2800 Louis Lumi re Suite 100 Q...

Отзывы: