o
Interface Box (Power Supply)
– 120VAC, 25 Amp circuit; L5-30 type locking plug. This
circuit must be dedicated to the vehicle.
o
Fiber Interface Box
– 100-250VAC, 3.15A.
o
Monitor and Keyboard Tray
– 100-240VAC.
o
Rack Mounted Power Bar
– 120VAC, standard 15 Amp circuit; NEMA 5-15P plug.
Input Voltage Transformer
Voltage Transformer
– In order to support system operation around the world, a voltage transformer
is included with the system. Both the Rack Mounted Power Bar and the Interface Box must be
connected to this voltage transformer whenever the system is to be powered from 200-240VAC. The
Interface Box (Power Supply) and the Rack Mounted Power Bar cords are bundled together and
joined to a single NEMA 5-15P plug which can be plugged directly into the voltage transformer.
Note:
The voltage selection jumper on the back of the voltage transformer must be set to the
appropriate mains voltage which the voltage transformer will be connected to.
Warning:
The VT300 system may be damaged if the voltage selection jumper on the back of
the input system voltage transformer is set incorrectly
.
Unpacking the System
The system is packed into two wooden crates for shipping and storage. Remove the Phillips-head screws
at the bottom of the crates to lift off the covers. One crate contains the winch and the other contains the
vehicle and control computer.
An overhead crane or engine hoist will be needed to move the winch from the crate base to its installed
position.
Note:
The crates are for shipping and storage only
– not for system deployment.
Note:
If the system is to be shipped or stored for any length of time, we recommend that it be packed
into its original shipping crate.