Microtrac
™ Voltages
The interface box provides tether power outputs for both 48V and 70V equipment. The VT100
™ crawler
is intended for 70V operation.
This vehicle should only be fitted with Microtracs
™ marked for 70V
DC supply.
48V rated tracks will be damaged if connected to this system.
Warning: Track Voltage Input
– Microtracs are supplied in two different voltage ranges: 36-
48VDC, and 30-70 VDC. Verify your tracks have the correct voltage input range for your
system. 48V rated tracks will be damaged if connected to a 70-Volt system. Wide input tracks
are designated by a
\V/
symbol on the side plate.
FIGURE 5 - MARKING FOR WIDE VOLTAGE INPUT TRACK