Nanomag™
Document: UMAM000196.docm
Revision: A06
Created by: JS
Date: 26 Sep 2019
IPN: 3024835-A06
Source Location: C:\ePDM\ISLEng\products\am-nanomag\manuals\UMAM000196.docm
Page 5 of 19
User Ma
nual
Focus
½” to
Rear Camera
Crystal Cam®
Pick-up Element
1/4
” CCD (NTSC or PAL)
Lens
3.6mm
Resolution
380 TV Lines
Illumination
0.5 lux
Focus
6” ~h
NanoMag™ Crawler
Dimensions
– (L x W x H)
224 x 105 x 50 mm
(8.8 x 4.1 x 2.0 in) (inline)
Weight
2.27 kg (5 lb)
Speed
2.5 m (8 ft) per minute
Tether Length
30 m (100 ft)
Operating Temperature
0 º - 50 ºC (32 ° -122 °F) Dependent on operating
conditions. Ask your sales expert for more
information.
Safety
•
All personnel operating or maintaining this equipment must read and understand the operations and
maintenance manual prior to system operation.
•
All personnel operating or maintaining this equipment must be competently trained.
•
Appropriate personal protective equipment (PPE) must be worn while operating and maintaining the
equipment.
•
Under no circumstances should this equipment be used in a potentially explosive atmosphere.
•
If the equipment is powered from a source other than an Eddyfi Technologies provided controller, the
power supplied to the product must have reinforced isolation from the mains with no reference to
earth ground.
•
The equipment must only be operated in a dry environment.