AM476230031, AM476240031, AM476250031

SYMPHOLIGHT Gateway BACnet

Information for Use

Содержание OSRAM SYMPHOLIGHT AM476230031

Страница 1: ...www ecue com Light is OSRAM Our Brand AM476230031 AM476240031 AM476250031 SYMPHOLIGHT Gateway BACnet Information for Use...

Страница 2: ...notice Typographical and other errors do not justify any claim for damages All dimensions should be verified using an actual part Modification of the product is prohibited This manual is designed for...

Страница 3: ...rks 08 3 1 Transport 08 3 2 Unpacking 08 3 3 Warranty regulations 08 3 4 Maintenance and Repair 08 3 5 Disposal 08 3 6 Support 08 4 Installation 09 4 1 Installation conditions 09 4 2 Mounting 09 4 3 E...

Страница 4: ...smartly in the building management system With the integrated web interface you can configure the SYMPHOLIGHT Gateway using a web browser save the configuration and call up statistics and documentati...

Страница 5: ...ntent for the e cue SYMPHOLIGHT Gateway BACnet 1 e cue SYMPHOLIGHT Gateway BACnet with 25 data points AM476230031 500 data points AM476240031 2 500 data points AM476250031 2 Safety instructions 3 Welc...

Страница 6: ...r interface Power supply on 2 pin terminal plug V 12 24 V DC or AC V GND or 12 24 V AC wire gauge 0 2 1 3 mm Ethernet Port 1 x Ethernet 10 100 Mbit s RJ45 User interfaces LEDs for Ethernet activity an...

Страница 7: ...ta point Flashing green Normal state Flashing orange and green Projected indicator S LED info Flashing red and green A failure parameter on defect S LED warning Red flashing Two or more failure parame...

Страница 8: ...noted in the quote and in the order confirmation See Services OSRAM Guarantee at www osram com for details Legal warranty regulations apply in any case 3 4 Maintenance and Repair This device requires...

Страница 9: ...e electrical cabinet and make sure that there is sufficient ventilation to ensure the specified temperature range 0 to 45 C 4 3 Ethernet connection Connect the SYMPHOLIGHT Gateway BACnet at the design...

Страница 10: ...configuration Enter the IP address of the SYMPHOLIGHT Gateway BACnet web server in a web browser http 192 168 123 1 Web browser support The integrated web server has been tested with various browsers...

Страница 11: ...ata point setup support via remote maintenance or on site contact support ecue com 6 Web interface operation and functions When you have successfully logged in you will see the gateway configuration i...

Страница 12: ...the front of the SYMPHOLIGHT Gateway BACnet System start The time at which the SYMPHOLIGHT Gateway BACnet system was last started Data points Displays the number of used data points and licensed data...

Страница 13: ...peration and functions Edit the input fields for this purpose 6 1 3 General IP network Configure the IP network settings on this configuration page i To save the settings on the configuration pages cl...

Страница 14: ...neral System time The SYMPHOLIGHT Gateway BACnet has an integrated battery powered real time clock for time keeping within the system Several protocols require the current time The system time must th...

Страница 15: ...onization the SYMPHOLIGHT Gateway BACnet takes its time from the specified NTP server Evaluating BACnet time synchronization The SYMPHOLIGHT Gateway BACnet listens for and evaluates sent BACnet messag...

Страница 16: ...function can be enabled as an option Contact us or click Request to order this option by mail 6 1 6 General Web services The gateway offers web services to read data point lists or change data points...

Страница 17: ...General Email Activate and configure the email service on this configuration page 6 1 8 General User The password for the user admin can be changed on this configuration page For security reasons you...

Страница 18: ...locally on your PC Restore gateway data backup When you select the Restore gateway data back up option the gateway reads an available data backup from your local data storage device and restores the...

Страница 19: ...Gateway BACnet system software Configure driver License request The current license is displayed License upgrade You can load the new license with this tab You will receive a license file from the ma...

Страница 20: ...update the SYMPHOLIGHT Gateway BACnet You will receive an update file from the manufacturer This must be stored on your computer and must be selected to update Please only select files that you have r...

Страница 21: ...nication software of the gateway If the system needs to be restarted this will pop up below the upper menu bar as a Restart Required button Alternatively you can also carry out a restart using the men...

Страница 22: ...er s data points Some selected drivers also have their own sub menu which you can use to adjust particular settings for that communication driver You can page through the data point list with the arro...

Страница 23: ...lue is the set nominal value i e the last value assigned by the SYMPHOLIGHT Gateway BACnet driver The Info button shows the properties of the selected data point The Edit button shows the current set...

Страница 24: ...ure So called failure data points exist for communication devices These show whether communication with a device is working value 0 or if communication with a device is faulty value 1 The values of th...

Страница 25: ...ormation dialogue and carry out a simple restart of the communication software Startup delay Here you can set a start delay for BACnet failure detection When restarting the SYMPHOLIGHT Gateway BACnet...

Страница 26: ...e Data links BACnet IP The following operating types are possible for BACnet IP connection normally BACnet BBMD BACnet Broadcast Management Device and BACnet Foreign Device The BACnet BBMD and FD conf...

Страница 27: ...e The table lists all BBMDs which are queried in a broadcast in addition to the devices in the particular network in order to reach the devices from other networks With Add you can create a new list e...

Страница 28: ...er of telegrams that a master node may send before the token has to be forwarded The possible value range is between 1 and 127 the default value is 1 If this property is not writable via BACnet this v...

Страница 29: ...iple initiated by gateway Incoming password BACnet PTP password for dialing up the SYMPHOLIGHT Gateway BACnet External networks The networks that can be accessed externally via BACnet PTP are configur...

Страница 30: ...of the SYMPHOLIGHT Gateway BACnet This is free descriptive text Location Defines the BACnet location of the SYMPHOLIGHT Gateway BACnet This is free text for the installation location Vendor identifier...

Страница 31: ...d Defines how many segments are accepted as a maximum APDU segment timeout This value defines the period of time after which an acknowledgment dependent segmented telegram is deemed to have failed in...

Страница 32: ...tive Timer operating seconds counter BACnet alarming is activated for this object with Intrinsic Reporting The Time Delay property determines the report delay in seconds All further information can be...

Страница 33: ...eration and functions Rows with a hash at the beginning are comments Rows without at the beginning are activated settings Confirm changes with Save Then close the information dialogue and carry out a...

Страница 34: ...figuration page and then download it from the SYMPHOLIGHT Gateway BACnet to your computer click Start 6 5 MQTT menu MQTT is a lightweight publish subscribe messaging protocol for the Internet of Thing...

Страница 35: ...ation dialogue and carry out a simple restart of the communication software 6 5 3 MQTT Files The entire MQTT configuration is saved in three files mqtt1 cfg driver mqtt1 txt data points dispatch txt g...

Страница 36: ...ning are activated settings Confirm changes with Save Then close the information dialogue and carry out a simple restart of the communication software 6 6 Help menu Contact information for the manufac...

Страница 37: ...Type Manufacturer s internal hardware designation GW version Manufacturer s internal protocol ID OS version SYMPHOLIGHT Gateway BACnet software version Build info Information about the software build...

Страница 38: ...includes the driver status data points and data point maps 6 6 5 Help Log files System You can activate deactivate a more detailed version of the log records for each communication driver using the b...

Страница 39: ...ter therefore automatically receives an IP address from the range in which the gateway works with its default IP address 192 168 123 1 This default address can be activated until the next restart by p...

Страница 40: ...ems For RS485 connections do not connect the GND especially between switching cabinets with different GND potentials if possible RS 485 A B wires reversed With swapped A and B data lines connection do...

Страница 41: ...ecue com and www traxontechnologies com OSRAM GmbH Sales Operations Karl Schurz Str 38 33100 Paderborn Germany 49 5251 54648 0 support ecue com www ecue com Head office Zentrale Marcel Breuer Strasse...

Отзывы: