background image

GEL DEEP CYCLE BATTERY

with integrated solar charger and display 

DC 38SC
DC 45SC
DC 65SC

DC 75SC
DC 85SC
DC 115SC

Bedienungsanleitung
Operating Instructions

DC Series

Содержание DC 115SC

Страница 1: ...GEL DEEP CYCLE BATTERY with integrated solar charger and display DC 38SC DC 45SC DC 65SC DC 75SC DC 85SC DC 115SC Bedienungsanleitung Operating Instructions DC Series...

Страница 2: ......

Страница 3: ...Handhabung Lagerung und Wartung 5 Ladevorgang 6 LCD Anzeige und Tagesz hler 7 Integrierte Alarmfunktion 9 Verwendung der Nachf llpacks 10 Warn und Sicherheitshinweise 12 Gew hrleistung Garantie 14 Se...

Страница 4: ...wird in Echt zeit berwacht und die Nutzungstage der Batterie werden aufgezeichnet Bei niedrigem Ladezustand der Batterie weist Sie ein automatischer Alarm darauf hin die Batterie umgehend zu warten Di...

Страница 5: ...r erreicht k nnen Sie diese F llpacks verwenden um die Lebens dauer Ihrer Batterie zu verl ngern Die Bleiplatte der Batterie besteht aus einer speziell entwickelten Materialmischung die der Batterie e...

Страница 6: ...olar strom schaltet der Solarladeregler in den Modus der Erhaltungsladung Notstromversorgung Bei einer Span nung von unter 11 6 V schaltet sich das System automatisch ab In einem Not fall k nnen Sie d...

Страница 7: ...rliegen Ist die Polspannung niedriger als die angegebene Spannung laden Sie die Batterie bitte sofort auf Bei Lagerung oder Nichtgebrauch laden Sie sie alle drei Monate auf um eine Tiefentladung zu ve...

Страница 8: ...abelle Beenden Sie den Ladevorgang wenn die Batterie besch digt werden k nnte Laden lagern und verwenden sie die Batterie ausschlie lich aufrecht um das Auslaufen von S ure zu vermeiden Spannung Spann...

Страница 9: ...digungen Halten Sie das Display sauber und trocken berpr fenSieregelm igdenaufdem Display angezeigten Batteriestatus Der integrierte Tagesz hler startet automatisch wenn die Batterie einge baut wird...

Страница 10: ...Serie Anschluss f r Solarladung Status LED Ladestandsanzeige Spannungsanzeige bzw Tagesz hler Button zum Wechseln zwischen Spannung sanzeige und Tagesz hler sowie zum Ausschalten des Alarms USB Anschl...

Страница 11: ...f dem Display angezeigt Reagieren Sie nicht innerhalb von 30 Minuten auf den Alarm wird der Ton automatisch deaktiviert Ca 4 Stunden sp ter ert nt der Alarm erneut Dies wiederholt sich dreimal bevor d...

Страница 12: ...acks und entfernen Sie die sechs Ventilkappen an der Oberseite der Batterie 3 Stechen Sie mit dem beiliegenden spitzen Kunststoffstab ein Loch in die Folienversiegelung des Nachf llpacks F hren Sie zu...

Страница 13: ...ie leeren Nachf llpacks Achtung Die zur Wartung verwendete F ll fl ssigkeit ist ungiftig aber tzend Bei Anheben des Deckels kann die Gummi kappe des Auslassventils hochspringen Verschlie en Sie das Au...

Страница 14: ...nem gut bel fteten Ort und halten Sie die Batterie von Funken und Flammen fern Halten Sie Werkzeuge und metallische Gegenst nde von den Batteriepolen fern um einen Kurzschluss zu vermeiden Achten Sie...

Страница 15: ...und Brandgefahr zu vermeiden Verwenden Sie die Batterie nicht direkt als Wechselstromquelle Dies k nnte zu Br nden Fehlfunktionen oder Sch den an der Batterie oder anderen Ger ten f hren Um die Batte...

Страница 16: ...ie klemmen Aufbewahren der Batterie ohne Elektrolyte Einf llen von Wasser oder nicht norm gerechter Elektrolyte in die Batterie Tiefentladung der Batterie Laden Sie die Batterie mindestens alle drei M...

Страница 17: ...auf Produktions und Material fehler die zum Zeitpunkt der Auslieferung des Produktes vorhanden waren F r gebrauchstypische Verschlei erschei nungen wird nicht gehaftet Die Gew hr leistung gilt nicht f...

Страница 18: ...hnen gerne weiter Hilfreich dazu ist meistens eine Vorab Info per E Mail evtl mit Erl uterung des Problems und Bildern Zur Kontaktaufnahme und f r R ck sendungen verwenden Sie bitte folgende Service A...

Страница 19: ...legen Sie der R cksendung folgendes bei Kopie der Rechnung Service Formular Grund der R cksendung Eine genaue und ausf hrliche Fehler beschreibung Entsorgung Bitte f hren Sie das gesamte Verpackungs m...

Страница 20: ...16 7 20 9 22 9 30 9 Spannung 12 V Ladeschlussspannung 14 4 V Erhaltungsladung 13 7V 50mV Grenzwert berspannungsschutz 16 V berladungsfreigabe 14 7 V Empfohlene max Entladung 80 LLVD 11 6 V BLVD 10 8...

Страница 21: ...gen zur Stromversorgung bei unschlagbarem Preis Leistungs Verh ltnis Erfahren Sie mehr zu unseren Produkten auf unserer Website ECTIVE DE batterium GmbH Robert Bosch Str 1 71691 Freiberg am Neckar Deu...

Страница 22: ...20 ECTIVE DC Series...

Страница 23: ...res and Functions 23 Use Storage and Maintenance 25 Charging the Battery 26 Display and Day Counter 27 Integrated Alarm 29 Using the Refill Packs 30 Warnings and Safety Advice 32 Warranty 34 Service C...

Страница 24: ...e battery is displayed in real time and the days of use of the Battery are recorded When the battery charge is low an automatic alarm prompts you to service the battery This battery can be used as a p...

Страница 25: ...ts life you can use these refill packs to extend the life of your battery The lead plate of the battery is made of a specially developed material mix ture that gives the battery a longer life The posi...

Страница 26: ...via solar power the solar charge controller switches to float charging mode Emergency power supply When the voltage drops below 11 6V the system automatically turns off In an emergency you can press...

Страница 27: ...hen stor ing or not using it recharge it every three months to avoid deep discharge Avoid deep discharging the battery If deep discharge occurs charge the battery immediately Remove the connection to...

Страница 28: ...aged Only charge store and use the battery upright to prevent acid leakage Voltage Maximum voltage Maximum current 12V 14 1 14 7V Max 25 of the nomi nal capacity in Ampere Deep discharge Charge the ba...

Страница 29: ...play from scratches and damage Keep the display clean and dry Check the battery status shown on the display regularly The built in days in use counter starts automatically when the battery is installe...

Страница 30: ...VE DC Series Input for solar charging Status LED Charge status Voltage day counter Button for switching between voltage display and days in use counter as well as for deactivating the alarm USB port O...

Страница 31: ...shown on the display If you do not respond to the alarm within 30 minutes the sound is automatically deactivated Approximately 4 hours later the alarm will sound again This is repeated three times bef...

Страница 32: ...move the six valve caps on the top of the battery 3 Using the supplied pointed plastic stick pierce a hole in the foil seal of the refill pack Insert one end of the injection tube into the refill pack...

Страница 33: ...fluid in the refill packs is non toxic but corrosive Please note that when the battery s top cover is lifted the rubber cap of the outlet valve may pop up Close the outlet valve with the rubber cap a...

Страница 34: ...p tools and metal objects away from the battery terminals to prevent short circuits When moving the battery avoid any tension on the connected cables as this may damage the cables or terminals Do not...

Страница 35: ...riate equipment such as an inverter Avoid contact of the sulfuric acid contained in the battery with skin eyes or clothing Avoid spilling acid from the battery If the acid comes into contact with skin...

Страница 36: ...urer s subsidiary in your country or the respective sales outlet In order to achieve the fastest possible warranty processing please include the following information A copy of the invoice with date o...

Страница 37: ...ck of maintenance Any use of the product is at your own risk A warranty claim can only be accepted if a copy of the purchase receipt is enclosed when the product is sent in In no case does the warrant...

Страница 38: ...ckar Germany T 49 7141 141 08 70 F 49 7141 560 90 49 info ective de ective de Tip When contacting us directly please have your customer or invoice number ready as well as and the article number In cas...

Страница 39: ...dispose of all packaging material properly or recycle it The German Electrical and Electronic Equipment Act ElektroG regulates the marketing disposal and recycling of electrical and electronic equipm...

Страница 40: ...eight kg 9 9 12 6 16 7 20 9 22 9 30 9 Voltage 12V Maximum voltage 14 4V Float charging voltage 13 7V 50mV Charge cut off voltage 16V Reconnect voltage 14 7V Reccomended max discharge 80 LLVD 11 6V BLV...

Страница 41: ...r power supply solutions at an unbeatable price performance ratio Visit our website to explore more of our brand and products ECTIVE DE batterium GmbH Robert Bosch Str 1 71691 Freiberg am Neckar Germa...

Страница 42: ......

Страница 43: ......

Страница 44: ...eine Marke der a brand of batterium GmbH Robert Bosch Stra e 1 71691 Freiberg am Neckar Germany Tel 49 7141 1410870 Fax 49 7141 1410875 ECTIVE DE...

Отзывы: