![ECR International Dunkirk DCB-100 Скачать руководство пользователя страница 26](http://html1.mh-extra.com/html/ecr-international/dunkirk-dcb-100/dunkirk-dcb-100_installation-operation-and-maintenance-manual_2356127026.webp)
22
5 - COMBUSTION AIR AND VENT PIPING
FIGURE 5-4 Roof Mount Coaxial Venting
CAN BE USED ON ALL SIZES
Maintain min. 12"(305
mm) US, 18"(457 mm)
Canada, clearance
above highest
anticipated snow level.
Max. clearance 24"
(610 mm) above roof
or ground
Anticipated
Snow Line
FIGURE 5-6 Side Wall Coaxial Venting
CAN BE USED ON ALL SIZES
Min. 8" (181 mm)
Max. 14" (356 mm)
Ground
Anticipated
Snow Line
18" Vertical
Clearance to
ventilated soffit
FIGURE 5-5 - Coaxial Vertical Exhaust -
CAN BE USED ON ALL SIZES
12" (305 mm)
Minimum Separation
Manufacturer
Recommends
Greater Separation
FIGURE 5-7 - Coaxial Horizontal Exhaust -
CAN BE USED ON ALL SIZES
Multiple
Appliances
Multiple
Appliances
24" (610 mm)
Min. Separation
Manufacturer
Recommends
Greater Separation
recommends gr
5.7 Coaxial Vent Screw Placement - See Figure 5-3
Two (2) screws shall be fastened through the outer intake pipe
behind the gaskets at equal distances, approximately 180°
apart. Note the screws used must be no larger than No. 8-3/4
sheet metal screws and must be zinc coated.
Figure 5-3 - Coaxial Screw Placement
1-3/4" (45mm)
3/4"
(19mm)
Maintain 12"(305 mm)
US, 18"(457 mm)
Canada, min. clearance
above highest
anticipated snow level.
Max. clearance 24"
(610 mm) ground
240013501 REV A [03/15/2022]
Содержание Dunkirk DCB-100
Страница 2: ...DCC 205...
Страница 4: ...DCB 165...
Страница 79: ...75 A 2 MODEL 75 100 Heat Only APPENDIX A WIRING DIAGRAMS 240013501 REV A 03 15 2022...
Страница 80: ...76 APPENDIX A WIRING DIAGRAMS A 2 MODEL 125 Heat Only 240013501 REV A 03 15 2022...
Страница 81: ...77 APPENDIX A WIRING DIAGRAMS A 3 MODEL 165 Heat Only 240013501 REV A 03 15 2022...
Страница 82: ...78 APPENDIX A WIRING DIAGRAMS A 1 MODEL 115 Combi 240013501 REV A 03 15 2022...
Страница 83: ...79 APPENDIX A WIRING DIAGRAMS A 4 MODEL 150 Combi 240013501 REV A 03 15 2022...
Страница 84: ...80 APPENDIX A WIRING DIAGRAMS A 5 MODEL 205 Combi 240013501 REV A 03 15 2022...
Страница 85: ...81 NOTES 240013501 REV A 03 15 2022...
Страница 86: ...82 NOTES 240013501 REV A 03 15 2022...
Страница 120: ...32 PN 240011430 REV Q 03 15 2022 CIRCULATOR CONNECTIONS WIRING DIAGRAM SINGLE ZONE CIRCULATOR WIRING USING ARGO AR822 II...
Страница 121: ...33 PN 240011430 REV Q 03 15 2022 75 100 HEAT ONLY WIRING DIAGRAM MODEL 75 100 HEAT ONLY...
Страница 122: ...34 PN 240011430 REV Q 03 15 2022 MODEL 125 HEAT ONLY 125 HEAT ONLY WIRING DIAGRAM...
Страница 123: ...35 PN 240011430 REV Q 03 15 2022 MODEL 165 HEAT ONLY 165 HEAT ONLY WIRING DIAGRAM...
Страница 124: ...36 PN 240011430 REV Q 03 15 2022 115 COMBI WIRING DIAGRAM MODEL 115 COMBI...
Страница 125: ...37 PN 240011430 REV Q 03 15 2022 MODEL 150 COMBI 150 COMBI WIRING DIAGRAM...
Страница 126: ...38 PN 240011430 REV Q 03 15 2022 MODEL 205 COMBI 205 COMBI WIRING DIAGRAM...
Страница 132: ...44 PN 240011430 REV Q 03 15 2022 LOW WATER CUTOFF DETAIL LOW WATER CUTOFF NO NO YES...
Страница 137: ...49 PN 240011430 REV Q 03 15 2022 3 FAULT SOLUTION SECTIONS...