Содержание WH51

Страница 1: ...rted 2 2 1 Parts List 2 3 Overview 3 3 1 Features 4 4 Setup Guide 7 4 1 Install batteries 7 5 Wi Fi Configure with gateway 9 5 1 Pair with Gateway 9 5 2 Wi Fi Connection for the Gateway 11 6 View Online Data on WS View 11 7 Custom mode 14 8 Specification 24 9 Warranty Information 25 ...

Страница 2: ...eway sold separately and can be viewed on our WS View mobile application after the Wi Fi configuration done Or a receiver console can be used to display the received sensor value To ensure the best product performance please read this manual and retain it for future reference 2 Getting Started 2 1 Parts List One Soil Moisture Sensor One User Manual ...

Страница 3: ...3 3 Overview 1 LED Indicator RF transmission 2 Battery Cap 3 Soil Moisture Sensor ...

Страница 4: ...brate the low high moisture value so that you can get more accurate result for different soil types This mode can only be activated through WS View app and in live data display mode Long wireless range up to 300 feet 100 meters in open areas When paired with a GW1000 Wi Fi Gateway Monitor live sensor data on the Live Data page of the WS View app ...

Страница 5: ...ed with a Weather Station Console HP2551 HP3500 HP3501 View soil moisture data in real time on the Display Up to 8 channels supported Channel names can be edited on the Display for HP2551 only When uploaded to Ecowitt Weather Server View current soil moisture data history records graph on the website Set and receive email alerts from the server ...

Страница 6: ... smart phone laptop or computer by visiting the website Note The WH51 and WN51 will be recognized as the same sensor type by the software If you purchased both they will share the eight channels together and the total quantity of the two sensors could not exceed eight ...

Страница 7: ...attery cap of the soil moisture sensor 2 Insert one AA battery and close battery cap 3 After inserting the battery the remote sensor LED indicator will light for 4 seconds and then flash once per 70 second thereafter Each time it flashes the sensor is ...

Страница 8: ...in air and see if moisture reading is 0 And then put the sensor into a cup of water the sensor should have its reading increased to 90 or above Once sensor detected a significant data change sensor will transmit every 10s Once sensor has been confirmed working correctly then you can go to next step 5 Insert the sensor totally into the soil of your desired location Please do not use excessive force...

Страница 9: ...ion sold separately 5 1 Pair with Gateway If GW1000 has been in operation and you have never had any WH51 soil moisture sensor setup before just power up the sensor and GW1000 will pick soil moisture data automatically Note The gateway can support max 8 soil moisture sensors Each new sensor will be recognized as a new channel according to the Power on sequence You may attach a label of the channel...

Страница 10: ...place the old one already configured on certain channel please try the following 1 Open the Sensor ID page on the WS View app and find your old sensor ID 2 Power off the old sensor and power on the new sensor 3 Click Re register on the Sensor ID page Then the new sensor will be learned and the old sensor will be erased ...

Страница 11: ... please refer to the manual of the GW1000 Wi Fi gateway Any question please contact the customer service 6 View Online Data on WS View When the Wi Fi configuration is done you can view the live data of your soil moisture sensor on the WS View application ...

Страница 12: ...12 ...

Страница 13: ...r data on the WS View app To remote monitor the sensor data please upload the data to our free Ecowitt Weather Server https www ecowitt net Detailed operation instructions can be found on the GW1000 manual Any question please feel free to contact our customer service at support ecowitt com ...

Страница 14: ...tom mode When in LIVE DATA display mode you can calibrate the soil moisture sensor by enable the Custom mode Click More Choose Calibration Choose Soil Calibration Tick the box on the left side of the Customize ...

Страница 15: ...15 ...

Страница 16: ...16 ...

Страница 17: ...17 ...

Страница 18: ...Soil Moisture moisture AD 0 AD 100 100 AD 0 AD Example when sensor moisture AD is 310 calculated moisture is 310 70 100 500 70 56 This is a fixed slope rate linear system Custom ON When pot soil at dry or wet condition is not giving the moisture sensor output value that is close to its default assumption it will give ...

Страница 19: ...to make this slope flexible so that it can match your soil type This becomes a variable slope rate linear system Adjusting principle 0 AD is used to adjust for dry condition reading inconsistency When the displayed moisture readings are too high at dry soil condition you could lower the slope rate by increasing the 0 AD value 100 AD is used to adapt for wet condition reading inconsistency ...

Страница 20: ...elow example for better understanding For example When you use this product at the first time you may turn off the custom mode and test the product at the following two situations Situation One Place the sensor into a glass of fresh water and the displayed moisture readings is much lower than 95 e g 70 Solution Enable custom mode and adjust the 100 AD ...

Страница 21: ...AD If Now AD 183 0 AD 70 Target Soil Moisture Reading 95 Then 95 183 70 100 100 AD 70 Result 100 AD 188 take the Integer part Then you can adjust the default 0 AD value to 188 and touch the screen for once to update the data When you get your expected moisture reading click Save to save the setting ...

Страница 22: ...yed moisture readings are much higher than 10 e g 40 Solution Enable the custom mode and adjust the 0 AD value Calculate the 0 AD value with the formula Soil Moisture moisture AD 0 AD 100 500 0 AD If Now AD 183 100 AD 500 Target Soil Moisture Reading 10 Then 10 183 0 AD 100 500 0 AD ...

Страница 23: ... you get your expected moisture reading click Save to save the setting Note The soil moisture sensor should be inserted totally into the soil for accurate result Record the 0 AD and 100 AD value for future use when WIFI network changed Note In general the device has been calibrated in the factory and you don t need to calibrate it on your side ...

Страница 24: ...00 AD setting range 0 AD 10 1000 Initial value default to its factory calibration Frequency 433 915 868 MHz optional Sensor reporting interval 70 seconds Transmission distance in open field 100m 300 feet IP66 waterproof Power consumption Soil moisture sensor 1xAA Alkaline batteries not included Battery life Minimum 12 months ...

Страница 25: ... materials and workmanship This limited warranty begins on the original date of purchase is valid only on products purchased and only to the original purchaser of this product To receive warranty service the purchaser must contact us for problem determination and service procedures This limited warranty covers only actual defects within the product itself and does not cover the cost of installatio...

Страница 26: ...26 or claims based on misrepresentation by the seller or performance variations resulting from installation related circumstances ...