EcoWater 7283560 Скачать руководство пользователя страница 1

SERIES 2000 & 2002

P/N: 7283560

cut

al

ong

dot

te

d

lin

e

to

rem

ove

tor

n

out

er

cover

Содержание 7283560

Страница 1: ...SERIES 2000 2002 P N 7283560 cut along dotted line to remove torn outer cover...

Страница 2: ...your EcoWater solid state water softener EcoWater Solid State ESS SERIES 2000 2002 Systems tested and certified by NSF International against NSF ANSI Standard 44 for water softener performance Systems...

Страница 3: ...equired by state and federal codes Use care when handling the softener Do not turn upside down drop or set on sharp protrusions Do not locate the softener where freezing temperatures occur Do not atte...

Страница 4: ...that the water conditioner is not damaged as the result of any unusual force of nature such as but not limited to flood hurricane tornado or earthquake EcoWater Systems LLC is excused if failure to p...

Страница 5: ...ter 25 gpg hard has a mineral content equal in size to 5 aspirin tablets Water hardness varies greatly across the country It generally contains from 3 to 100 gpg Hard water affects living in general...

Страница 6: ...the acidity A neutralizerfilter or a chemical feed pump are usually recommended to treat acid water 4 SEDIMENT is fine foreign material particles sus pended in water This material is most often clay...

Страница 7: ...ATER CONDITIONED WATER bypass valve 7214383 INLET OUTLET PLUMBING OPTIONS S ALWAYS INSTALL either an EcoWater bypass valve 7214383 or a 3 valve bypass system By pass valves allow you to turn off water...

Страница 8: ...tings as required H 1 2 I D high quality flexible hose for the valve drain and brine tank drain The brine tank drain el bow accepts either 1 2 or 3 8 I D hose VALVE DRAIN OPTIONS Flexible drain hose i...

Страница 9: ...tlet within 10 of the unit The trans former has an attached 10 power cable for con nection between the outlet and the timer S Position the softener at least 6 from surrounding walls or other appliance...

Страница 10: ...ATER SUPPLY a Close the main water supply valve near the well pump or water meter b Shut off the electric or fuel supply to the water heater c Open high and low faucets to drain all water from the hou...

Страница 11: ...he inlet and outlet tubes from the valve Remove o rings from the tubes DO NOT solder with tubes in the valve Soldering heat will damage the valve NOTE If installing a ground as shown in Figure 8A plac...

Страница 12: ...a pliers NOTE Route the tubing neatly out of the way and cut it to the desired length For longer distances or der the optional parts shown on page 29 to extend the tubing CAUTION When removing and in...

Страница 13: ...of the timer CAUTION Be sure all wiring is away from the valve cam which rotates during regenerations a Plug the transformer into a continuously live grounded 120VAC 60Hz house electrical outlet appr...

Страница 14: ...AM or PM as applies also shows 2 Press the SELECT keypad to set the present time B Set Hardness 1 Press the UP or DOWN keypads to select your waters hardness level Default is 25 2 Hardness level can b...

Страница 15: ...itioner is regenerating because the water heater will refill with bypass hard water VACATION To suspend regenerations while gone for extended periods press do not hold the RE CHARGE keypad VAC will sh...

Страница 16: ...eypads adjust the back wash time from 0 minutes to 60 minutes ADJUSTABLE FAST RINSE Press and hold the SELECT button until the display shows 000 then press the SELECT button four times to ad vance to...

Страница 17: ...water and held by the resin beads Conditioned water exits the resin tank through the bottom distributor flows up the internal standpipe into the valve and out to the house pipes In time the resin bead...

Страница 18: ...lt storage area A controlled water flow to the brine tank takes place during fill To enter fill the softener valve repositions slightly motor energized A valve passage opens allowing conditioned water...

Страница 19: ...ve float seats to prevent air induction Water con tinues to flow in the same direction except for the dis continued brine flow Hardness minerals and brine rinse from the resin bed and flow to the drai...

Страница 20: ...M S FIGURE 15 STEP 4 BACKWASH The motor drives the valve to end brine rinse and begin backwash In backwash a fast upward flow of water through the resin bed flushes remaining hardness minerals brine...

Страница 21: ...water If the storage tank is full of salt it is hard to tell if you have a salt bridge Salt is loose on top but the bridge is under it Take a broom handle or like tool and push it straight down into t...

Страница 22: ...t lose o ring seals or other small parts Refer to the assembly instructions page 5 and to installation steps 1 12 15 and 17 to reassemble and restart the unit MODEL NUMBER RESIN TANK SIZE FREEBOARD RA...

Страница 23: ...pen HOT and COLD conditioned water faucets 3 Push the bypass valve handle to bypass position Note For hard water bypass to house fau cets reopen the main water supply valve PRESSURIZE 1 Open HOT and C...

Страница 24: ...irst time electrical power is applied to the face plate Press the UP keypad to display the number of days this face plate has had electrical power ap plied Press the DOWN keypad to display the number...

Страница 25: ...ave washer defective etc 4 Again press the RECHARGE keypad to move the valve into backwash Look for a fast flow of water from the drain hose a If flow is slow check for a plugged top distributor backw...

Страница 26: ...tially restricted valve drain hose top distribu tor backwash flow plug resin tank internal riser or bottom distributor continued FLOODED SALT TANK 1 Nozzle venturi plugged 2 Defective valve seals 3 Re...

Страница 27: ...24V NC NO BACK OF TIMER WIRING SCHEMATIC POSITION SWITCH TRANSFORMER 24VAC FOR FUTURE REFERENCE ENTER THE FOLLOWING INFORMATION MODEL NO DATE CODE WATER HARDNESS GPG SERIAL NO INSTALLATION DATE IRON...

Страница 28: ...3 Max Drain Flow Rate gpm 3 0 3 0 These systems conform to NSF ANSI 44 for the specific capacity claims as verified and substantiated by test data MODEL NOMINAL RESIN TANK SIZE A B C ESS 2000R30 10 DI...

Страница 29: ...pair Parts ECOWATER S Y S T E M S 8 7 9 10 40 32 33 34 35 36 37 11 12 13 24 14 15 16 18 19 26 23 21 22 21 22 28 20 17 18 19 27 38 41 42 43 13 30 1 2 3 4 6 44 39 29 31 Valve Assembly see page 30 20 5 1...

Страница 30: ...7112882 Hose Clamp not shown 23 7218604 Brine Tank cabinet 24 7287386 Rim cabinet KEY NO PART NO PART DESCRIPTION 25 7214244 Vapor Barrier 26 7273997 Salt Hole Cover 27 7274008 Brine Tank Cover 28 721...

Страница 31: ...30 Repair Parts ECOWATER S Y S T E M S 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 12 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 35 9 34 10 36 37 38 39 40 41 42 43 44 45 46...

Страница 32: ...0 7167659 Screen Support 21 7146043 Screen 22 7187772 Nozzle Venturi Gasket Kit 7204362 Gasket only 23 1148800 Fill Flow Plug 3 24 7137507 Nozzle Venturi Assembly KEY NO PART NO PART DESCRIPTION 25 70...

Страница 33: ...ECOWATER S Y S T E M S 3 EcoWater Systems PO Box 64420 St Paul MN 55164 0420 651 739 5330...

Отзывы: