Ecovolt JT4B Скачать руководство пользователя страница 1

JTB Electric Radiators Installation

and Operational Manual

JT4B and JT6B versions

JT

4B R

adiat
or

JT

6B R

adiat
or

www.ecovolt.ie

Содержание JT4B

Страница 1: ...JTB Electric Radiators Installation and Operational Manual JT4B and JT6B versions JT4B Radiator JT6B Radiator www ecovolt ie...

Страница 2: ...petent person All electrical work to be completed by a qualified electrician Please dispose the package properly Towel Rail Installation 1 Drill 2 Screwdriver s 3 Spirit level 4 Cable cutters 5 Measur...

Страница 3: ...wall where the 4 female brackets are to be positioned It is important to line the male spigot bracket attached to the heater to your markings Using the drill drill 4 holes in the wall and insert wall...

Страница 4: ...and secure using the small screw supplied ensuring the spade connections are secured and tight It is recommended that only qualified personnel carry out this Fixing the heater to the female brackets L...

Страница 5: ...th wire green yellow into the earth terminal E of the isolating switch When all 3 wires have been terminated to the 230V supply switch is it then safe to turn on the heater The heater will now begin t...

Страница 6: ...as shown below a Power specification AC230V 50HZ b Temperature range 0 55o C c Setting temperature range 7 30o C d Time mode 24 hour e Week mode 1 7 f Timing mode Multiple setting 1 hour step g Progr...

Страница 7: ...Setting the temperature at 7o C Icon this setting is fixed 3 5 Timing setting Time adjustment adjustment range 0 24H Icon 3 4 Timing mode Timing function Icon 3 6 Programming modes Class II only Six m...

Страница 8: ...The default temperature is 19o C As shown Press or to set the temperature press to increase the temperature press to reduce the temperature in 0 5o C steps hold or down to speed the temperature adjust...

Страница 9: ...5S every time press to adjust the minute Adjustment range is 0 59 in minute segments Hold down or to increase the adjustment speed Note If there is no activity in 30 seconds the timing setting will e...

Страница 10: ...P1 Comfort mode 06 00 22 00 Economy mode all other times outside these times P2 Comfort mode 06 00 09 00 and 16 00 22 00 Economy mode all other times outside these times P3 Comfort mode is 06 00 09 00...

Страница 11: ...the day programming modification if there is no activity within 30S 4 2 5 Programming mode It has six programming modes 1 Comfort mode This is your primary heating mode to reach your comfort level Th...

Страница 12: ...will appear on the display as shown below The keypad is now locked To unlock the keypad press and hold and for 3 seconds Temperature calibration setting Press for 10 seconds when the heater is in the...

Страница 13: ...discretion of Ecovolt replacement with a functionally equivalent product The Ecovolt guarantee is valid for 2 years from the date of purchase of your Ecovolt product or date of delivery The Ecovolt gu...

Страница 14: ...olt trained personel of its authorised agents and any parts that are replaced with become the property of Ecovolt Any repairs performed under the guarantee will not extend the guarantee period The Eco...