Electrical Requirements:  

The system requires 208 

 220 volt, 3 phase, 30 amps, 4 wire system WYE Wired 

and will run on 50 or 60 HZ.  

 

This electrical connection should be a straight run back to the panel and the 

breakers marked to distinguish the Eco 250 connections from any other installed 

service.  

 

You must supply both electrical connectors for your site  

1. Wall to electrical panel  

2. And System to wall (Your electrician will be able to assist you with these 

requirements) 

 

Physical Requirements: (45.3”*39.4”*41.4”):

 

The Eco 250 units come with casters that lock for easy positioning of the unit.  

The unit can be placed outside provided that the unit is protected from the 

elements. Rain, snow and ice can and will damage the electrical portions of the 

unit.  

 

A drain line, to remove condensate from the system is included. The condensate 

can then go directly to the main drain as it contains no chemicals or sediments and 

is gravity fed.  

 

The drain must be below the output from the unit and must drain away from the 

unit to insure fluid movement.  

 

A heater switch for the water reservoir is provided for colder climates to keep the 

water from freezing (see operator manual) 

 

 