background image

                                           

 
 

Portable inverter gasoline generator series 

Owner’s Manual 

Original instruction 

 

 

 

EP2200i                            EP2500i                          EP2500iC 

 

 

 

ECOUS POWER SYSTEMS, INC. 

801 S Figueroa, St #1000, Los Angeles, CA, USA 90017 

 

Содержание EP2200i

Страница 1: ...Portable inverter gasoline generator series Owner s Manual Original instruction EP2200i EP2500i EP2500iC ECOUS POWER SYSTEMS INC 801 S Figueroa St 1000 Los Angeles CA USA 90017...

Страница 2: ...achine once sold Important information Particularly important information is distinguished by the notations as follows This is the safety alarm symbol which alerts you to potential personal injury haz...

Страница 3: ...is manual contains latest products information when printed there may be minor discrepancies in actual machine There are also some changes in machine for different countries according to various requi...

Страница 4: ...EXHAUST HIGHLY FLAMMABLE AND POISONOUS FUEL 10 HOT ENGINE AND MUFFLER 11 ELECTRIC SHOCK PREVENTION 11 EXTENSION CORD NOTES 12 CONNECTION NOTES 12 DESCRIPTION 13 CONTROL PANEL 14 CONTROL FUNCTION 14 MA...

Страница 5: ...OPERATION 20 STARTING THE ENGINE 21 APPLICATION RANGE 23 AC CONNECTION 24 STOPPING THE ENGINE 25 PERIODIC MAINTENANCE 26 MAINTENANCE CHART 26 CARBURETOR ADJUSTMENT 27 SPARK PLUG INSPECTION 28 ENGINE O...

Страница 6: ...5 STORAGE 34 DRAIN THE FUEL 34 ENGINE 35 IDENTIFICATION 36 WIRE DIAGRAM 37 SPECIFICATIONS 38...

Страница 7: ...him if you are in doubt as to proper specifications and or maintenance procedures Occasionally printing errors or production changes will make certain portions of this manual incorrect Until you are...

Страница 8: ...7 Safety and instruction labels...

Страница 9: ...r more details The Safety Alert Symbol means Attention Become alert Your safety is involved Read the manual before operation Be careful of poisonous exhaust Never operate the machine in a closed area...

Страница 10: ...rine use Do not use it in a closed vehicle Do not modify or use the generator when any component removed Do not allow children to use the generator Make sure to move the generator only by carrying its...

Страница 11: ...on the Engine or muffler when refueling If you carelessly swallow any fuel inhale fuel vapor or allow any fuel into your eye please go to hospital immediately If you spill any fuel on skin or clothin...

Страница 12: ...lding or other equipments if not the generator may be overheated 1 meter 3 feet Do not operate the generator when a dust cover or other stuff covered Make sure the engine and muffler are completely co...

Страница 13: ...more reduction of voltage between the generator output socket and the load connection will be Therefore choose an extension cord with an appropriate length This extension cord should be protected by...

Страница 14: ...harging the main power line back feeding when the main power supply has failed or has been turned off for a line repair Back feeding can electrocute or injure line maintenance personnel Also generator...

Страница 15: ...MAIN SWITCH OFF ignition circuit and fuel supply are off and engine stops ON ignition circuit and fuel supply are on and engine can be started to work ECO SWITCH ON When ECO switch is in position ON e...

Страница 16: ...below the Lower level low oil alarm will be on and engine will stop automatically Unless you refill engine oil engine will not be started again Engine oil alarm NOTE If engine can not be started pleas...

Страница 17: ...devices within the application range and press the reset button generator will recover to output 2 For generator without reset function disconnect all electric devices and stop engine 3 Reduce total w...

Страница 18: ...moved turn vent knob counterclockwise from ON to OFF to avoid possible fuel overflow or vapor Vent knob Fuel tank cap RESET BUTTON When generator stops output due to overload Disconnect all electric...

Страница 19: ...y spilled fuel to avoid corrosion on parts surface or plastic parts Must use unleaded fuel to avoid serious corrosion on engine inner components Open fuel tank cap fill with fuel till red mark inside...

Страница 20: ...oil filled Do not tilt the generator when filling engine oil which may result in overfilling and damage to the generator Place generator on a level surface and check the oil level of oil filter hole...

Страница 21: ...plied generator should connect with earth ground Ground earth terminal OPERATION OPERATION CONDITION WARNING Never operate the generator in a closed area or it may cause unconsciousness or death withi...

Страница 22: ...altitude the higher altitude the lower air pressure and humidity The generator output will reduce when temperature humidity and altitude are higher than standard atmospheric condition In addition plea...

Страница 23: ...does not stop when the choke button is back to original position NOTICE Choke cable button should be back to original position when generator works normally otherwise generator will not work well NOT...

Страница 24: ...40VA 612VA 2500i 2500iC 2100VA 1680VA 714VA NOTE The overload alarm indicator is on red When total watts exceed the application range See page 15 for more details NOTICE Make sure the total load is in...

Страница 25: ...other electrical devices located near the generator If the generator is to supply medical equipment advice should first be obtained from the manufacturer a medical professional or hospital Some electr...

Страница 26: ...icator is ON Green AC output indicator 4 Turn the ECO Switch to the position ON and then turn on all electric devices NOTICE When using electric devices that require a large starting current such as c...

Страница 27: ...ion will keep your generator in long term safe and efficient condition The key points of periodic inspection adjustment and lubrication are explained on the following pages WARNING If you are not fami...

Страница 28: ...ead Decarbonizes cylinder head More frequently if necessary Valve clearance Check and adjust when engine is cold Fittings fasteners Check all fittings and fasteners Correct if necessary The point wher...

Страница 29: ...plug type and clearance Standard spark plug A5RTC TORCH Spark plug clearance a 0 6mm 5 Install spark plug Spark plug torque 12 15N m 6 Install spark plug cover NOTE When installing spark plug twist it...

Страница 30: ...nd To professional waste oil disposal 4 Place the generator on a level surface and add engine oil to lower level of filter port Lower level NOTICE Do not tilt the generator when filling engine Oil or...

Страница 31: ...engine and muffler directly with any part of your body or clothing during inspection and repair 1 Remove screws on both sides and disassemble exhaust cover Screw Exhaust cover 2 Loosen clamp and remov...

Страница 32: ...tighten them 6 Install exhaust cover and tighten the screws on both sides AIR FILTER 1 Loosen screws and remove air intake cover Screw Air intake cover 2 Loosen screw remove air filter cover and take...

Страница 33: ...g air filter cover check and place the sealing strip on air filter correctly 7 Assembly air intake cover and tighten screws FUEL TANK FILTER Open fuel tank cap and take out inlet filter screen Remove...

Страница 34: ...OOTING Engine will not start 1 No fuel supplied to combustion chamber There is no fuel in tank Add fuel There is some fuel in tank Check vent knob on fuel tank cap and turn it to position ON Clogged f...

Страница 35: ...sconnect all electric devices reduce total wattage of connected electric devices within the application range and press the reset button Reset button For generator without reset function stop the engi...

Страница 36: ...dding the fuel Make sure to wipe up any spilled fuel immediately to avoid damage on rubber or plastic parts 4 Start the engine and leave it run in empty load until it automatically stops without any r...

Страница 37: ...erior part of the generator 4 Store the generator in a dry and well ventilated place with a clean cloth covered 5 The generator must remain in a vertical position when stored carried and operated IDEN...

Страница 38: ...37 WIRE DIAGRAM...

Страница 39: ...7M is the arithmetic mean value in four directions measured 7 meters away from each side of the generator The noise level may vary in different environments NOISE LEVEL The figures quoted are emissio...

Страница 40: ...39 ECOUS POWER SYSTEMS INC...

Отзывы: