Installation Manual

LTP0108 REV 1

Important

Read this document before operating / installing this product

Содержание AquaCal AutoPilot

Страница 1: ...Installation Manual LTP0108 REV 1 Important Read this document before operating installing this product...

Страница 2: ......

Страница 3: ...ternal Controller 22 1 5 h Programming for an External Controller 23 1 6 Service Level Programming 25 1 6 a Service Level Factory Defaults 26 1 6 b Enter Service Level Programming 27 1 7 Cleaning Equi...

Страница 4: ...ing 39 4 Appendix 42 4 1 Identifying Model Specifications 42 4 2 Weights 43 4 3 Heating Recommendations 43 4 4 Cooling Recommendations 43 4 5 Available Accessories 44 5 Troubleshooting 45 5 1 Fault Co...

Страница 5: ...ust be performed by an authorized service center l Warranties may be voided if the equipment has been improperly installed maintained or serviced l If service is deemed necessary please see Contacts o...

Страница 6: ...persons having an adverse medical history or pregnant women should consult a physician before using a hot tub or spa Children and the elderly should be supervised by a responsible adult l Prolonged i...

Страница 7: ...mation contained throughout the Installation section is intended for use by qualified installation technicians familiar with the swimming Pool Spa safety standards NOTICE Failure to heed the following...

Страница 8: ...Page 4 Eco Therm ET075 Eco Therm ET095 and ET110...

Страница 9: ...Page 5 Eco Therm ET135 Eco Therm ET120R and ET165R...

Страница 10: ...ation Drain Kit STK0202 on page 44 Mounting Pad Requirements l Build the heat pump pad out of concrete or other code approved material l Confirm the pad can support the weight of the heat pump See Wei...

Страница 11: ...the proper operation of the heat pump l Avoid storing chemical containers near the heat pump The chemicals can cause equipment damage l Avoid placing objects near or on top of the heat pump This inclu...

Страница 12: ...mp This will not be covered under equipment warranty See Water Flow Rates on page 13 l Install a bypass valve whenever water flow may exceed maximum rating l See 5 lb Bypass Valve Kit STK0135 on page...

Страница 13: ...Page 9 Heat Pump with water flows greater than maximum listed flow rate See Water Flow Rates on page 13 Heat Pump with Spillover Spa One filter Pump...

Страница 14: ...Page 10 Heat Pump with Spillover Spa Two filter Pumps Heat Pump with Solar Panels in Plumbing Circuit Heat Pump with Gas Heater backup...

Страница 15: ...Page 11 Multiple Air Source Heat Pumps Multiple Air Source Heat Pumps Reverse Return Detail...

Страница 16: ...g unions l Plumbing unions are available from Eco Therm See Available Accessories on page 44 NOTICE Failure to heed the following may result in damage to equipment l Do not use glue on the threaded po...

Страница 17: ...MINIMUM MAXIMUM ET055 Titanium Tube in Tube 20 GPM 45 GPM ET075 Titanium Tube in Tube 20 GPM 45 GPM ET095 Titanium Tube in Tube 30 GPM 70 GPM ET110 Titanium Tube in Tube 30 GPM 70 GPM ET135 Titanium T...

Страница 18: ...mperature ports are strongly recommended for residential installations Temperature Port Shown with Probe 1 Adjust thermostat to its lowest setting with unit in heating mode 2 Deactivate the water filt...

Страница 19: ...s clean l Filter pump is operating l The valves are set to direct the appropriate amount of water through the heat pump See Water Flow Rates on page 13 l FLO is displayed or displays intermittently WA...

Страница 20: ...flow switch See Available Accessories on page 44 1 5 Electrical 1 5 a Electrical Requirements WARNING Failure to heed the following may result in injury or death l The information contained in this s...

Страница 21: ...cal heat pumps air conditioners and dehumidifiers UL1995 CSA C22 2 236 05 Heating and cooling equipment Table 2 Standards Grounding and Bonding Follow local code requirements for properly grounding an...

Страница 22: ...nt using the same electrical panel as the heat pump 2 If measured site voltage is outside listed ranges immediately deactivate equipment until site conditions have been corrected If unsure of heat pum...

Страница 23: ...Page 19 1 5 b Incoming Power Access Holes Eco Therm ET120R and ET165R Eco Therm ET055 and ET075 Eco Therm ET095 ET110 ET135...

Страница 24: ...easured voltage found on the site Incorrect settings may cause heat pump damage The following procedure will allow the installer to set the heat pumps transformer for the appropriate site voltage WARN...

Страница 25: ...unit fails to operate at start up the orientation of the line voltage field wiring may need to be adjusted l The phase monitor is located inside the electrical panel Three Phase Monitor 1 Deactivate p...

Страница 26: ...installed and follow the appropriate instructions l A two wire controller with an internal thermostat The user can set and adjust the temperature at the controller s screen l A three wire controller...

Страница 27: ...eactivate power to heat pump 2 Remove heat pump electrical access panel 3 Route the control wiring to the low voltage side of the electrical enclosure Follow all National Electric Codes NEC unless Sta...

Страница 28: ...l 3 three wire Using FS2 interface Press Up and Down buttons simultaneously until CF1 appears Press Pool Spa button until LOC is displayed Press Up or Down to passcode Default is 17 Press Pool Spa but...

Страница 29: ...cess a locked keypad will reset all settings to factory default including any installer entered configuration Re programming all custom site condition settings will be required when using this reset S...

Страница 30: ...djust db5 Spa Dead Band Differential 1 Set at factory Do not adjust DEL Compressor Time Delay 1 4 minutes Set to on at 4 minutes at the factory Do not adjust dSC Defrost Sensor Factory Calibrated Set...

Страница 31: ...n provide automatic pool spa thermostat switching Press Up and Down buttons simultaneously until CF1 appears Press Pool Spa button until LOC is displayed Press Up or Down to passcode Default is 17 Pre...

Страница 32: ...is complete 1 7 Cleaning Equipment After Installation Installer If you need to clean equipment after installation please use the following guidelines WARNING Failure to heed the following may result i...

Страница 33: ...careful not to damage evaporator fins APPROVED CLEANING AGENTS Fantastic Formula 409 Cascade All Power Plain Detergent 3 Solution Table 4 Cleaning Agents Polishing 1 Polish the heat pump s cabinet pan...

Страница 34: ...st l The display reads 888 l The heat pump then displays as normal See Display on page 31 2 3 Wake Up Heat Pump The heat pump s control panel has a sleep mode This is used to prevent rain that hits th...

Страница 35: ...water flow is detected The filter pump is off or heat pump is not receiving correct water flow OFF The heat pump has been turned off via the mode selector button or the temperature set point has been...

Страница 36: ...his light will illuminate Water Temp Indicates current water temperature Desired Temp Indicates temperature set point is displayed This is displayed when UP or DOWN is selected 2 5 User Level Programm...

Страница 37: ...t to maintain a water temperature set on the thermostat CF1 Celsius Fahrenheit Selection 1 0 Celsius 1 Fahrenheit ELC Enter Lock Code 0 0 99 ULC User Lock Code 0 0 User Lock Disabled 1 User Lock Enabl...

Страница 38: ...tarts the heat pump will attempt to maintain the set temperature within 3 The red Heating or blue Cooling light will activate l Off The heat pump will indicate it is deactivated The current water temp...

Страница 39: ...mp on page 30 l If LOC is briefly displayed followed by a 0 the heat pump is already locked l If the user lock code has been misplaced please contact Eco Therm for further assistance Hold UP and DOWN...

Страница 40: ...ess Heat Pump If LOC is briefly displayed when attempting to change a heat pump s settings followed by a 0 the heat pump has the user lock enabled A numerical pass code is required to proceed Press UP...

Страница 41: ...or the Spa thermostat l Rapid movement between thermostats without a rest between each change can cause a missed signal by the heat pump Deactivating Heat Pump l Go to the heat pump and set the mode t...

Страница 42: ...ppm Cyanuric Acid 30 50 ppm 30 50 ppm pH 7 4 7 6 ppm 7 4 7 6 ppm Total Alkalinity 80 120 ppm 80 120 ppm Calcium Hardness 200 400 ppm 150 250 ppm Total Dissolved Solids 0 1 500 ppm 1 500 ppm above star...

Страница 43: ...with Unit 19 Identify Environmental Conditions of Concern Run Off Sprinklers etc 20 Perform Operating Orientation As Applicable 3 3 Winterizing Failure to properly winterize the heat pump as needed m...

Страница 44: ...anger 1 Deactivate all electrical power to heat pump 2 Deactivate filter pump 3 Remove front access panel See Access Panels on page 20 4 Identify heat exchanger from illustrations in this section Then...

Страница 45: ...a clean rag around the hose to form a temporary seal 9 Push all water from the water circuit using compressed air no stronger than 50 psig The residual water should be forced out of the heat pump s w...

Страница 46: ...ually posted on the side of the equipment or the inside of the heat pump s access plate 2 Find the model number on the data plate The first letters and numbers indicate the model type 3 The complete m...

Страница 47: ...ump for continuous operation l This will allow the Heat Pump the time required to heat the water at start up l After the water has reached the desired temperature reset the filter pump to normal opera...

Страница 48: ...all units from one lead unit and prevents the simultaneous start up of multiple heat pumps l Site voltage drop is minimized and utilities are not subjected to large in rush demands of electrical curr...

Страница 49: ...id the heat pump warranty FLO Indicator ISSUE Low or no water detected RESOLUTION 1 Confirm the filter pump is on 2 If a multiple speed filter pump is being used run at a higher speed to determine if...

Страница 50: ...ed technician should replace the water sensor HP Indicator ISSUE The refrigerant system s high pressure switch is showing as open RESOLUTION If the heat pump is a reversing unit place it in HEA mode a...

Страница 51: ...s of heavy ice buildup on the coil LP5 Indicator ISSUE The heat pump has locked due to five LP low pressure faults during one call for heating RESOLUTION 1 Deactivate then reactivate power to the heat...

Страница 52: ...luminated l If not confirm the main breaker located at the power supply panel and the disconnect switch located near the heat pump are both turned on l If the display still does not illuminate it is r...

Страница 53: ...has a sufficient run time The heat pump will not run or heat the water without water flow Heat Pump equipment will generally be set to run 24 hours a day in commercial applications See Heating Recomm...

Страница 54: ...ate can begin to freeze Forming frost then ice What to expect l The heating of the pool or spa water continues while frost and ice develop l The heat pump is designed to periodically enter a defrost s...