Installation Manual & User Guide

 

 

INSTALLATION & USER MANUAL  
EAS SERIES

  

for Space 

heating

 and 

cooling

System description…………………………………… 

Declaration of conformity…………………………… 

Installation details…………………………………… 

Safety precautions …………………………………… 

Transportation & storage…………………………… 

Before starting installation…………………………. 

Installation sequence ………………………………. 

Inspection of installation …………………………… 

Locating the heat pump…………………………… 

Protection ……………………………………………… 

Ventilation……………………………………………… 

Drainage………………………………………………… 

Placement checklist…………………………………… 

Radiator heating system.................................... 

In-floor heating system..................................... 

Connecting the heat pump................................ 

Flushing the heating system.............................. 

Connecting to heating system........................... 

 

Commissioning the heat pump.......................... 

Operating temperatures.................................... 

Maintenance...................................................... 

Technical specifications EAS 700/1000.......... 

10 

Technical specifications EAS 1500/2500........ 

11 

Tips to Increase savings................................... 

12 

Wiring diagram................................................ 

13 

Replacement parts list...................................... 

13 

 
Troubleshooting guide…………………………… 

14 

 

 

 

 

Installation and maintenance guide 

 

This manual is designed to provide the 
information necessary to correctly install and 
operate the Heat Pump.   

The guide lists topics in the order that we, as 
manufacturers, recommend all installations and 
commissioning should be carried out. 

All Ecotec Heat Pumps must be installed by a 
licensed, authorised or qualified heat pump 
installer.  The Installer should be familiar with 
local building regulations, exacting Health and 
Safety Regulations and building control 
requirements where appropriate.  

There are no refrigeration connections or 
refrigerant requirements since all Ecotec units 
come pre-charged from factory and are leak   
tested prior to delivery. 

Copyright © Ecotec Heat Pumps Ltd – E&OE 

 

Содержание EAS 1000

Страница 1: ...Technical specifications EAS 1500 2500 11 Tips to Increase savings 12 Wiring diagram 13 Replacement parts list 13 Troubleshooting guide 14 Installation and maintenance guide This manual is designed to...

Страница 2: ...eat domestic and potable water via external heat exchanger or cholrifier cylinder system that indirectly heats the water EAS units should not be used for direct heating of potable water EAS is not int...

Страница 3: ...l unit optional Installation sequence 1 Position the heat pump on solid base or footing see locating the heat pump 2 Install pipe work using pipe rated for the type of installation and operating tempe...

Страница 4: ...because of the risk of slip hazards from ice buildup Condensation in humid climates can be in excess of 30 liters per day so proper drainage around the unit is important Placement checklist Units sho...

Страница 5: ...heating circuit to ensure equalization of pressure losses to all parts of the system Thermostatic radiator valves TRV s should be fitted in accordance with building regulations To ensure adequate wate...

Страница 6: ...ch longer to raise the floor temperature on initial start up although once operating it will stay at the correct temperature due to thermal mass Because heat pumps generate a lower temperature heating...

Страница 7: ...isture Minimum recommended insulations thickness is 19mm 3 4 Sensor cables and communication lines should be separated from high voltage cable by 20cm 8 to prevent interference The total water volume...

Страница 8: ...ead 43 C radiators or 33 C in floor and then open each radiator or zone one at a time waiting for the return water temperature to rise each time 8 Once the whole system is open allow the water tempera...

Страница 9: ...build up around the base of the unit For sea side installation extra attention must be given to cleaning the units to remove salt buildup which will cause rusting For high corrosive environments we re...

Страница 10: ...aluminum propeller type Direct drive 4 blade No of axial fan 2 2 No fan Steps 3 step off low high automatic selection Hydraulic circuit External pump to be specified by installer Recommended water fl...

Страница 11: ...num propeller type Direct drive 4 blade No of axial fans per unit 4 4 4 No fan Steps 3 step off low high automatic selection Hydraulic circuit External pump to be specified by installer Recommended wa...

Страница 12: ...f necessary Fan control Three step fans are controlled by a pressure switch on the refrigerant circuit This can be adjusted if necessary to ensure the high speed is engaged with a low outdoor temperat...

Страница 13: ...ck the pressure safety switch your heat pump is protected by High and Low pressure safety switches that will activate if water line pressure is too high or low Tripped Low pressure switch The low pres...

Страница 14: ...ing or replacing the filter if that doesn t work call a heat pump repair technician Room temperature goes too high or too low When room temperature rises higher or drops lower than the set temperature...

Страница 15: ...the following parts are available from your authorised installer Soft starter 4 way valve Fan motor Fan blades Phase PR 3 minute time relay Danfoss High Pressure switch Danfoss Low Pressure Danfoss Dr...

Страница 16: ...Ecotec Heat Pumps Ltd Installation Manual User Guide 16 Make a note before you forget...

Страница 17: ...formation Model Number ___________________________________ Serial Number ___________________________________ Purchase Date ___________________________________ Installer Name Address Phone ____________...

Отзывы: