Страница 3: ...N 7 PERFORMANCE CHANGES 7 Recirculating Smart Drive System 7 ELECTRONICS 8 STAND BY MODE 9 WATER TEMPERATURE SENSING 9 WATER VALVES 9 RECIRCULATING VALVE 9 STATOR 10 PUMP 10 SIZE SETTING MODE Same as...

Страница 4: ......

Страница 5: ...Height to Lid Open 1350mm 1380mm 4ft 5inc 4ft 6inc Closed 900mm 930mm 35 13 32inc 36 19 32inc Width 650mm 25 1 2inc Depth 650mm 25 1 2inc Inlet Hose Length 1200mm 43inc Weight Packed 57 5kg 126lbs Unp...

Страница 6: ...e 64 ohms 20 C 68 F Flow Rate 16ltrs min 4 2 gal min Operating pressure Max 1034 kpa 150PSI Min 20 kpa 3 PSI THERMISTOR NTC type temperature sensor Resistance 10 000 ohms 25 C 77 F RECIRCULATING VALVE...

Страница 7: ...hose and back into the bowl onto the clothes with a fan like spray pattern As the water recirculates the bowl will stir pausing every 16 seconds Short top ups may occur as garments absorb water keepi...

Страница 8: ...models This has been made possible by changes to the stator winding which allows a lower current through the electronics and the use of the latest low loss semiconductor switching device With the Ser...

Страница 9: ...rchangeable with previous model Smart Drive washing machines The terminals have been changed to the RAST 2 5 system Extra care must be taken to ensure these connections are plugged in squarely to avoi...

Страница 10: ...anged During the drain cycle the pump is stopped and started quickly every 10 seconds When the pump stops the water keeps flowing flushing away any lint in the pump chamber The pump is now part of the...

Страница 11: ...ed pump to be normal however the inductance of the pump can change causing it to overheat and cut out There are new fault codes in the system which now relate to the pump circuit and its extended func...

Страница 12: ...the advance button to toggle between them To enter the DIAGNOSTIC MODE 1 Turn the power on at the power point and off at the console 2 Press and hold the WASH TEMPERATURE DOWN then press the POWER bu...

Страница 13: ...GRESS LED s will now display the fault code By using a BINARY NUMBERING SYSTEM each unique fault code can be given a number 3 1 EXAMPLES OF BINARY CODE Wash Progress LED s Binary Code Detailed Fault C...

Страница 14: ...LED to respond after the Out of Balance has been activated Also when in this mode with the MEDIUM SPIN SPEED LED on the SPIN LED will display the SIZE SETTING 3 3 DRAIN PUMP TEST The REGULAR CYCLE bu...

Страница 15: ...ration and to reset the RE START feature to the factory setting switch the machine off at the wall or disconnect from the mains supply 3 6 RE CYCLE FEATURE WATER LEVEL UP button turns the RE CYCLE fea...

Страница 16: ...on the wash progress LED s and beep continuously The hold and slow spin LED s will also be displayed During the above process the beeper will sound continuously It is advisable to switch the machine...

Страница 17: ...mary Secondary and Tertiary fault source system These sources have mostly been arranged in order of most likely source of fault but in some cases the sequence has been modified to aid the servicing pr...

Страница 18: ...0 Motor Controller Module Fault The Motor Controller Module has received an incorrect signal from the pressure sensor Primary Source Motor Controller Module Action Replace Motor Controller Module 7 00...

Страница 19: ...filled with water may have caused this Primary Source Motor Controller Module Action 1 Check tub is fully pumped out Remove pressure tube from pressure sensor clear pressure tube of any water and reco...

Страница 20: ...is fault One is that the drain hose has been squashed or kinked and the pump out rate has been dramatically reduced The second possibility is that the pump is partially or fully blocked The third is t...

Страница 21: ...kinked or has fallen off completely Alternatively the pressure sensor may be faulty Primary Source Mechanical Action Check that the pressure tube is intact and not blocked with water dirt or kinked S...

Страница 22: ...onnected to the normally closed position If the harness terminals show signs of corrosion then fit a new harness Tertiary Source Motor Controller Module Action Replace Motor Controller Module 44 00101...

Страница 23: ...other foreign objects preventing the clutch from re engaging 2 Next check that the pressure tube has not come off and that it is not kinked Secondary Source Motor Controller Module Action Replace Mot...

Страница 24: ...10100 Diverter valve top up fault The machine has exceeded the maximum number of top ups during re circulation Check to see if water is leaking from drain hose during re circulation Primary source Div...

Страница 25: ...are the clutch and pressure tube If these two appear correct then the fault could be with the pressure transducer in the Motor Controller Module Primary Source Mechanical Action 1 Check that there ar...

Страница 26: ...as reported this to the Display Module 62 00111110 Pump Over current Fault The motor controller has detected excess current in the pump windings Most likely caused by water leaking onto pump Primary s...

Страница 27: ...ult are a bad connection on the harness between the Rotor Position Sensor and the Motor Controller Module or a faulty Rotor Position Sensor Primary Source Wiring Action 1 Check for corrosion on the ed...

Страница 28: ...e motor current AND a Rotor Position Sensor error simultaneously See fault codes 130 and 132 for service procedure 136 10001000 Motor Stall The Motor Controller Module has been unable to start the mot...

Страница 29: ...Source Motor Controller Module Action Replace Motor Controller Module 162 10100010 Brake Deceleration Time out Fault During the brake mode the Motor Controller Module has detected that the basket has...