background image

 

Range 4 

– B30M 

Operating instructions

 

 

ECOSAFE | Date du document : 30/04/2019 – Version : 01 

 

of  flexible  sheath)  ;  the  fan  included  in  the  box  extracts  the  toxic  vapors  contained  in  the  cabinet,  and  reject  it  to  the  outside  of  the 

building thanks to the roof or wall extraction.   

 

If you cannot reject the vapors to the outside, you need a filtration box.  

 

Filtration boxes

 are equipped with an activated carbon filter, which purifies the toxic vapors in the box, and rejects it in the room in a 

healthy fashion. Filtration boxes are delivered with the activated carbon filter that you need to renew once a year.  

 

Running without any mechanic ventilation 

It  is  possible  for  your  safety  cabinet  to  run  without  mechanical  ventilation.  However,  your  cabinet  has  to  be  placed  in  a  location  that 

provides its own ventilation system (at least 5 times the volume of the location, per hour).  

The cabinet itself and a radius of 2,5 meters directly around is a dangerous area subject to explosions.  

 

On the other hand, if the ventilation system of your cabinet is not running, you have to indicate it, by putting an etiquette on the cabinet, 

saying “Safety cabinet not connected to the mechanic ventilation” (etiquette is not provided). 

 

 

7.  SAFETY CONTROLS 

 

Your safety cabinet is a safety equipment. As to guarantee its perfect efficiency, you have to check the equipment regularly.  

 

Daily safety controls : 

 

Check  if  th

e  products  (liquids,  powders…)  have  flowed  in  the  containment  sumps.  If  it  has,  they  have  to  be  emptied  and 

cleaned promptly, with suitable 

equipment (absorbent mat…). 

 

Check that the cabinet and its internal equipments are not corroded.  

 

Check that the cabinet does not have any mechanical damages.  

 

Check the proper closing of the doors.  

 

Check the proper working of the locking system.  

 

Monthly safety controls : 

 

Check the proper working of the doors (opening and closing)  

 

Check the working of your ventilation system thanks to, for example, a piece of paper  

(Only if your cabinet is connected to a mechanical ventilation system) 

 

8.  SPARE PARTS 

 

Elements :  

 

Handle with integrated locking system : 

Contact us 

 

Standardized pictogram : 

Contact us

 

 

Shelf with polyethylene protection : P/N 

ESP30

 

 

 

Содержание B30M

Страница 1: ...Range 4 B30M Operating instructions ECOSAFE Date du document 30 04 2019 Version 01 0 Instruction manual For safety cabinet Model B30M ...

Страница 2: ...ONTENT 1 Description Use Page 2 2 Technical features Page 2 3 Installation and commissioning Page 2 4 Internal equipments Page 3 5 Storage Page 3 6 Ventilation Page 3 7 Safety controls Page 4 8 Spare parts Page 4 9 Recycling Page 4 10 Warranty Page 5 11 Control sheet for the user Page 6 ...

Страница 3: ...anual door that open to a full 180 degrees 3 point locking system Shelves adjustable on 3 76 mm centers for versatile storage Leakproof 2 51 mm bottom sump Dual vents with flame arresters 4 self leveling feet Grounding connector External dimensions H 1120 x W 1090 x D 460 mm Internal dimensions H 1025 x W 1005 x D 390 mm Storage capacity 113 liters Retention capacity 20 liters Loading capacity 75 ...

Страница 4: ...t the chosen height thanks to the rack and pinion Take care not to exceed the loading capacity per shelf of 75 KG The cabinet also has an integrated retention tank which has a retention capacity of 20 liters The cabinet is provided with polyethylene trays attached to the galvanized steel shelves and a separate polyethylene liner for the bottom sump 5 STORAGE Your safety cabinet is exclusively dest...

Страница 5: ...s On the other hand if the ventilation system of your cabinet is not running you have to indicate it by putting an etiquette on the cabinet saying Safety cabinet not connected to the mechanic ventilation etiquette is not provided 7 SAFETY CONTROLS Your safety cabinet is a safety equipment As to guarantee its perfect efficiency you have to check the equipment regularly Daily safety controls Check i...

Страница 6: ...nt as they are the only one able to determine the condition Repair of the equipment must be performed in our warehouse The spare parts are under 3 months warranty upon their settlement The warranty cannot be applied in the following cases The equipment has not been stored used or maintained in accordance with the standards by the user In case of a damage of the equipment by the user or a third par...

Страница 7: ...y The locking system of the doors works correctly The mechanic ventilation system is running correctly if applicable The ventilation system is not obstructed The air inlet and outlet are clean The standardized pictogram on the door is in good condition and visible The door hinges are lubricated The locking system is lubricated The containment sump is clean Remarks Date By Signature ...

Отзывы: