Содержание EP-1000-UV

Страница 1: ...TION GUIDE ecoPLUS EP 1000 UV PLEASE READ THIS MANUAL CAREFULLY BEFORE ATTEMPTING INSTALLATION FAILURE TO FOLLOW THESE INSTRUCTIONS MAY AFFECT THE PERFORMANCE OF YOUR SYSTEM VOID YOUR WARRANTY AND RES...

Страница 2: ...n against bacteria viruses and other microorganisms ecoPLUS delivers refreshing great tasting drinking water protects your skin and hair from the damaging effects of these contaminants and gives you p...

Страница 3: ...ect Outlet Assembly to the Bypass Assembly 13 Step 8 Connect the Bypass Assembly to Valve Head 14 Step 9 Connect the Inlet Assembly to the Housing Cap 14 Step 10 Connect the Bypass to the Inlet Assemb...

Страница 4: ...heavy components without assistance if you are not physically capable of safely carrying out the procedure If the water treatment system is to be left unattended for an extended period of time vacatio...

Страница 5: ...0 PSI Maximum Water Pressure 90 PSI Recommended Water Pressure 40 70 PSI Water Temperature 36F to 100F 2 to 38C Minimum Air Temperature 32 F 0 C pH Range 6 5 to 8 5 Maximum Service Flow Rate 15 GPM 37...

Страница 6: ...E CODES ARE IN CONFLICT THE RELEVANT PLUMBING ELECTRICAL CODE SHALL BE FOLLOWED EQUIPMENT FAILURE PERSONAL INJURY OR PROPERTY DAMAGE CAN RESULT IF THIS EQUIPMENT IS NOT INSTALLED PROPERLY KEEP THE MED...

Страница 7: ...7 Step 1 Pre Installation Inspection Inspect all of the components that you received with your unit You should have received the following...

Страница 8: ...nector 1 NPT to 1 NPT 36 26 UV Parts Bag Contains sleeve bolt sleeve o ring and 2 chamber mounting clamps Step 2 Selecting an Installation Location While exterior installation in warm climate areas is...

Страница 9: ...utor which looks like a cone shaped plastic screen There is a recess in the center of the tank to accept the distributor to keep it properly aligned The riser tube has been pre cut to the correct heig...

Страница 10: ...er Use all of the media provided Using a small scoop to add the media slowly will help reduce dust Next add the Catalytic Carbon marked Media 4 in the same manner Use all of the media provided Using a...

Страница 11: ...bricant is provided in the small parts bag Do NOT use petroleum jelly The ecoPLUS Valve Head can now be secured to the top of the tank Before attaching the Valve Head check to make sure that there is...

Страница 12: ...ur wall using the remaining four 4 lag bolts and washers as shown below The top of the mounting bracket should be mounted EXACTLY 52 3 4 52 75 inches off the floor Use a carpenter s 52 3 4 inches from...

Страница 13: ...ump Remove the protective plastic wrap from the sediment pre filter and place it in the cartridge filter housing sump At the bottom of the sump there is a raised portion in the middle standpipe that w...

Страница 14: ...us media tank as shown Again note the position of the fitting stops The threaded collars of the bypass assembly should thread right up to the fitting stops with no gap Excessive force is not required...

Страница 15: ...the collet to securely lock the fitting Step 10 Connect Bypass to Inlet Assembly Position the ecoPLUS media tank to align the bypass assembly with the inlet assembly attached to the cartridge filter...

Страница 16: ...up and tapping it on a hard surface while holding it perpendicular to the floor A few light taps will generally straighten it out Thread the inlet assembly on to the bypass assembly as shown in the s...

Страница 17: ...r s Manual Section 3 1 Installing UV System to mount and install your UV sterilizer Be sure that you install the disinfection chamber such that the flexible connector can reach the inlet port at the b...

Страница 18: ...black end of the flexible stainless steel connector threads onto the stainless steel fitting in the same way as you would attach a garden hose to an outdoor faucet Do not use Teflon tape or other thre...

Страница 19: ...in the bypass position see next page for diagram Turn on the main water supply Open a cold water tap nearby and let the water run for a few minutes until the system is free of foreign material and air...

Страница 20: ...urged from the system Continue until all air is purged Then turn off the faucet and allow the media to soak for a minimum of twenty four 24 hours Set the bypass valve to the bypass position so you can...

Страница 21: ...fully conditioned and saturated It is common and normal for some carbon dust to be released from the filter in the first few days of operation This carbon is harmless and will generally go away withi...

Страница 22: ...ound in the Viqua UVMax E4 Owner s Manual Section 6 MAINTENANCE THE SYSTEM MUST BE DEPRESSURIZED BEFORE REMOVING ANY COMPONENTS FOR SERVICING TO DEPRESSURIZE THE SYSTEM CLOSE YOUR MAIN WATER SHUT OFF...

Страница 23: ...g O ring should be replaced at least once annually or at each filter change if any damage to the O ring is noted kinked cracked stretched etc or if any leakage between the housing cap and the housing...

Страница 24: ...ver a period of time the sleeve may become etched or damaged If cleaning is no longer effective in restoring clarity to the sleeve it should be replaced Complete UV maintenance instructions can be fou...

Страница 25: ...ated Carbon Calgon Carbon Corporation Moon Township PA USA Made in USA NSF ANSI Standard 61 Centaur Catalytic Activated Carbon Calgon Carbon Corporation Moon Township PA USA Made in USA NSF ANSI Stand...

Страница 26: ...mprehensive warranty program including Limited Lifetime Warranty on major components Major components including the cartridge filter housing media tank s riser tube s upper media screen s and tank val...

Страница 27: ...e United States of America In the event that a part is deemed defective the user must immediately inform HomePlus Products Inc who will furnish a replacement part at no cost to the user HomePlus oblig...

Страница 28: ...xceed the actual purchase price paid by the authorized distributor or consumer for the product In no event shall HomePlus Products Inc be liable to the distributor or any other person or entity for sp...