ECOPERLA VITA 12 Скачать руководство пользователя страница 1

WWW.ECOPERLA.COM

VITA

WATER 

S

OFTENER

ECOPERLA 

VITA

U

S

ER MANUAL

original product of Ecoperla

Содержание VITA 12

Страница 1: ...VITA WATER SOFTENER ECOPERLA VITA USER MANUAL original product of Ecoperla...

Страница 2: ...KEEP THIS USER MANUAL SINCE IT CONTAINS THE WARRANTY AND THE SERVICE CARD...

Страница 3: ...ion of operation mode 5 4 2 Brine up time 5 4 3 Backwash time 5 4 4 Rinse time 5 4 5 Fill time 5 4 6 Ion exchange capacity 5 4 7 Regeneration frequency 5 4 8 Regeneration time selection 5 4 9 Relay 1...

Страница 4: ...eration 6 4 User maintenance 6 5 Medium cleaning 6 6 Medium disinfection 6 7 Consumables 6 8 Loss of warranty 7 Service 7 1 Activities carried out by the service technician 7 2 Groundless request of w...

Страница 5: ...ansient hardness The second type is non carbonate hardness also referred to as non transient hardness It is responsible for presence of substances such as chlorides nitrates sulphates soluble salts in...

Страница 6: ...uring regeneration is directed to the sewage system 1 4 OPERATION AND MAINTENANCE Proper operation of the device requires regular refilling of the salt container with salt tablets The regeneration fre...

Страница 7: ...h 1 5 m3 h Maximum flow rate m3 h 2 0 m3 h 3 0 m3 h Operating pressure bar 2 0 6 0 2 0 6 0 Salt consumption per regeneration kg 1 5 3 0 Water consumption per rinsing L 85 130 Width mm 320 320 Height m...

Страница 8: ...amage the electronic board A pre filter must be installed before the water softener The device should be placed vertically and on a hard flat surface The device should also be transported vertically T...

Страница 9: ...ect Raw water Raw water 1 5 2 7 3 4 6 1 2 3 4 5 6 7 1 Main water shut off valve 2 Inlet valve to Ecoperla Vita 3 Mechanical water filter 4 Ecoperla Vita 5 Outlet valve from Ecoperla Vita 6 Bypass valv...

Страница 10: ...to the sewage system the outlet to the sewage system on the control valve is made of plastic 3 4 internal thread The outlet to the sewage system should preferably be made of plastic tubes 25 mm or 32...

Страница 11: ...t the first regeneration by pressing REGEN for 5 seconds Open the water inlet valve gently to avoid water hammer Supervise subsequent stages of regeneration and check tightness of the system When rege...

Страница 12: ...REMAINING M3 12 00 4 41m3 5 PROGRAMMING 5 1 OPERATING MODE DISPLAYS Current time Remaining ion exchange capacity Instantaneous flow rate Press NEXT to move to the next display The menu is displayed in...

Страница 13: ...inal hardness is hardness of water flowing out of the device Entering final hardness does not mean its actual change It refers to the change of the ion exchange capa city when mixing water In order to...

Страница 14: ...ts In the case of Ecoperla Vita we recommend setting the re generation time to 2 a m as the water demand is lowest at this time Press NEXT twice to move to the end of the control valve setting You can...

Страница 15: ...settings SET SOFTENING 5 4 1 Selection of operation mode Press up and down to select the operation mode softening and filtration For Ecoperla Vita select softening Press NEXT to move to the next stag...

Страница 16: ...5 Salt fill in kilograms Press up and down to enter the amount of salt in kilograms Press NEXT to move to the next stage You can return to the previous step by pressing REGEN SET 0 9 5 4 6 Ion exchan...

Страница 17: ...return to the previous step by pressing REGEN SET TIME REGEN NORMAL on 0 5 4 8 Regeneration type selection Press up and down to select one of three regeneration types DELAYED regeneration starts at t...

Страница 18: ...g on which condition is met first REGENERATION VOLUME In the next two steps you set the condition activating the signal time since regeneration volume since regeneration or volume and the duration min...

Страница 19: ...nd down simultaneously and hold the buttons until the message on the display changes 5 5 1 Number of days since regeneration REGEN DAY 14 The screen displays the number of days since the last regenera...

Страница 20: ...to select a day Press NEXT to move to the next stage You can return to the previous step by pressing REGEN 5 5 5 Maximum instantaneous flow The screen displays the maximum instantaneous water flow rea...

Страница 21: ...s NEXT to move to the next stage You can return to the previous step by pressing REGEN REGEN 13 18 61 M 5 6 4 Total volume The screen displays the total volume of water treated by the device Press NEX...

Страница 22: ...ith respect to iron and manganese content turbidity pH chloride and microbial content Suitable working conditions temperature within the required limits low humidity in the room protection against atm...

Страница 23: ...f drinking water exceed quality standards in terms of iron and manganese content turbidity pH chlorides and microorganisms No pre filter no cartridge in pre filter Wrong hydraulic connection e g inter...

Страница 24: ...ent of the pre filter cartridge Salt refilling Providing consumables Checking change of controller settings Mixer adjustment Control valve piston guide etc cleaning 7 2 GROUNDLESS REQUEST FOR WARRANTY...

Страница 25: ...d The water meter is not connected to control board d Connect the water meter to the ME TER connector on the control board e Defective water meter e Replace the flow meter f Defective control board f...

Страница 26: ...e not com patible i Select compatible correct control valve and piston j Contaminated medium j Replace the medium 9 Control valve uses too much regene rant a Wrong fill settings a Check fill settings...

Страница 27: ...tside the control valve b Check the piston and gaskets piston guide Check the gears mounting and gearbox Reset the PC board c The drive gears are too tightly screwed to the housing c Loosen the gears...

Страница 28: ...and ga skets of the MAV NHBP valve and reset the control board 19 1007 defect the display shows code alternating with Error The MAV SEPS NHBP valve motor ran too short and did not stop in the correct...

Страница 29: ...chnician Signature of the service technician Stamp of the service technician Stamp of the service technician Maintenance service after 6 years of operation Date of maintenance service Maintenance serv...

Страница 30: ...h the warranty conditions included in the user manual In order to execute the warranty you need to present proof of purchase of the system In the case of a problem with the Ecoperla Vita system please...

Страница 31: ...31 NOTES...

Страница 32: ...WWW ECOPERLA COM...

Отзывы: