background image

WHF

Smart

C o n t r o l

Jan 2020

CAUTIONS

Use cautions when mounting components to surfaces that 
may have concealed wiring beneath the surface.

Turn off power before installing whole house fan or controls.

Read and follow all instructions carefully, including those 
included with the whole house fan. Read entire manual 
before installing products.

Follow all local electrical codes during installation. All wiring 
must conform to local and national electrical codes.

Installation should be performed by a qualified individual 
with sufficient experience and skill.

!

The RT3K kit includes an RT3 Remote control with 
two AAA batteries already installed, an RM3 Radio 
Module, an FC3J Fan Control and a 7’ plug&play 
cable. 

When servicing WHF controls, turn off all power to these 
items.

INSTALLER MANUAL

Model RT3K

Whole House Fan Remote Control

Wire the FC3J to the fan using the diagram below as a guide. If 
the FC3J fan control is already installed on the fan, go to Step 2.

Step 1. Install FC3J in Junction Box on Fan

Connect to FAN High 

Speed Wire 

Connect to FAN Low 

Speed Wire
Connect to FAN Medium 

Speed Wire

Connect to POWER 

120VAC Wire 

Connect to FAN Neutral 
Wire and to POWER 
120VAC Neutral Wire

LS

MS

HS

120

VAC

NTL

Low Speed

Medium Speed

High Speed

120VAC Power

Neutral

Unused wires should be cut at the 
PCB or capped with wire nuts.

!

Laguna Hills, CA

eControls

eControls

Model FC3J

eControlsUSA.com

For 1, 2 or 3-Speed PSC or ECM Fans

WARNING

 

120V

AC. 

Disconnect all 

power before wiring 

Violet-High Speed
Yellow-Med Speed

Red-Low Speed
Black-120V

AC

White-Neutral

Wiring Key

Use the screws included to secure the 
FC3J to the junction box on the fan 
making sure there are no exposed 
wires and the fan control is securely 
inside the electrical box. Failure to do 
so could result in electrical shock.

Step 2. Connect RM3 to the FC3J

Connect the FC3J Fan Control installed in the junction box on 
the fan to the RM3 Radio Module using the plug&play cable 
provided.

Insert cable into FC3J 

installed on fan.

Laguna Hills, CA

eControls

eControls

Model FC3J

eControlsUSA.com

For 1, 2 or 3-Speed PSC or ECM Fans

WARNING

 120V

AC. 

Disconnect all power 

before wiring or 

servicing.

Violet-High Speed

Yellow-Med Speed
Red-Low Speed
Black-120V

AC

White-Neutral

Wiring Key

ON/OFF

SPEED

MODE

H

ON

SPEED

Indoors

WHF

Smart

Cool Set To

ODT

ODT

Model RM3

WHF Radio Module

ODT

ODT

Laguna Hills, CA

eControlsUSA.com

Insert cable into 

RM3.

Use cable 

provided.

Step 3. Power the Fan

If you are installing the optional outdoor temperature 
sensor, install the sensor first then power the fan. See 
page 2 for sensor installation.

Model RM3

WHF Radio Module

ODT

ODT

Laguna Hills, CA

eControlsUSA.com

Apply power to the fan. 
automatically starts up, remove 
power and check the wiring . If the 
problem persists, contact us.

The LED on the RM3 Radio Module 
blinks yellow until communication 
with the RT3 Remote has been 
established. 

If the fan 

See FC3J Wiring Diagrams on pages 3-4 for wiring to 
fans manufactured by QC Manufacturing.

i

i

Отзывы: