Page 56
ecom-EN2
Description of data record ecom-EN2 with Multi Media Card
Format data logger records: J2KDL-xx.csv (separation mark between values = comma)
Format punctual measurements: J2KDV.txt (separation mark between values = comma)
Column Description
Remark / Example
A
Date
DD.MM.YYYY (also US-Version)
B
Time
HH:MM:SS (also US-Version)
C
O
2
in vol.%
0,0 - 21,0
D
CO in ppm
0 - 4000
E
NO in ppm
0 - 5000
F
NO
2
in ppm
0 - 1000
G
SO
2
in ppm
0 - 5000
H
CO converted*
I
NO converted*
J
NO
2
converted*
K
NO
x
converted*
L
SO
2
converted*
M
T.Gas in °C or °F
0 - 500 (US-Version with other range in °F)
N
T.Air in °C or °F
0 - 99 (US-Version with other range in °F)
O
Draught in hPa
0,00 - 20,00
P
CO
2
in vol.%
0,0 - 25,0
Q
Efficiency in %
0,0 - 120,0
R
Losses in %
0,0 - 100,0
S
Excess air
> 1,00
T
Dew point in °C or °F
0 - 500 (US-Version with other range in °F)
U
Poisoning index
> 0,0
V
O
2
(gas channel check) in vol.% 0,0 - 21,0
W
CO (gas channel check) in ppm Related to 0,0 vol.% O
2
X
CO (gas channel check) in ppm Measured value
Y
O
2
(O
2
check) in vol.%
0,0 - 21,0
Z
T. Boiler
0 - 999
AA
T. Sensor
0 - 99
AB
O
2
reference
0,0 - 21,0
AC
Unit
0=ppm; 1=mg/m
3
; 2=mg/kWh; 3=mg/MJ
AD
Norm
N = converted to O
2
ref.
AE
Fuel type number
Index acc. to instrument table
AF
Fuel type text
Text acc. to instrument table
AG
Soot 1
0,0 - 9,9
AH
Soot 1
0,0 - 9,9
AI
Soot 1
0,0 - 9,9
AJ
Oil trace
0=no; 1=yes;
AK
20 characters text
AL
20 characters text
AM
16 characters text
AN
Serial number
AO
CO (O
2
check) in ppm
AP
Zug (O
2
check) in hPa
AQ
C
x
H
y
AR
Number copy data
AS
T1 (deltaT-measurement)
AT
T2 (deltaT-measurement)
AU
Velocity
m/s
AV
CO Environment
CH-version = Kind of control
AW
free
CH-version = Load range
AX
Comment text
AY
Comment text
AZ
Comment text
BA
Comment text
BB
H
2
in ppm
CH version = Oil consumption
BC
H
2
converted*
CH version = Thermal output
BD
Sensor 6 in ppm
CH version = Operation hours counter
BE
Sensor 6 converted *
CH version = Code