background image

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 

 

 

Initiation and Measurement 

 

•Check fine dust filter.  
 -Change if grey color > 3 of soot scale. 
 -

Change if extended past “MAX” mark. 

 
•Connect sampling probe. 
 
•Press ON/OFF switch . 
 
•Start gas measurement with <Enter> 
 
•Select fuel type and confirm with <Enter> 
 
•If needed, select storage location. 
 
•Wait for auto-zero phase to complete. 
 
•Position sampling probe in exhaust pipe. 
 
•Search for stream core. 
 
•Wait at least 2 minutes for stabilization of 
 measurement values. 
 
•Store values in intermediate memory by 
 pressing <Store> (the disc symbol). 
 
•If needed, print measured values by 
 pressing <Print> (IR printer required) 
 
•If needed, store measurement  in selected 
 storage location (<Enter> / <Store to memory> / 
<Enter>). 
 
•Remove sampling probe from exhaust pipe and 
 let it cool down. 
 
•Press ON/OFF key of instrument to switch off. 
 

Technical Data

 

 

Paramenter  

 

Range   

 

 

Principles 

O2  

 

 

 

 

0 ... 21 vol-%    

electrochemical 

CO 

 

 

 

 

0 ...4000 ppm    

electrochemical 

NO (Option)  

 

0 ...5000 ppm    

electrochemical 

CO2    

 

 

 

0 ...CO2 max.    

calculated 

T-G    

 

 

 

0 ... 500 °C    

 

NiCr/Ni 

T-R    

 

 

 

0 ... 100 °C    

 

semiconducter 

Pressure  

 

 

0 ... +/- 100 hPa   DMS-bridge 

Efficiency    

 

0 ... 120 %    

 

calculated 

Losses    

 

 

0 ... 99,9 %   

 

calculated 

Lambda   

 

 

1 ... 

  

 

 

 

calculated 

CO-undiluted    

 

 

 

 

 

 

calculated 

(reference-O2; adjustable)    

 

 

Dew point of combustion gases  

 

calculated 

 

Power Supply

   

110 - 230 V~ / 50 - 60 Hz; 

Battery

    

 

 

6 V / 3,3 Ah 

Display

    

 

 

graphic display, backlit 

Size (W x H x D)

   250 mm x 180 mm x 80 mm 

Weight

   

 

 

approx. 2,1 kg (complete with 

 

 

 

 

 

 

sampling system) 

 
 

 

 

 
 
      

 

 

Subject to technical changes 

V1.0/ 02.2014

 

 
 

ECOM America 

1628 Oakbrook Drive 

Gainesville, GA 30507 

Tel.  770.532.3280 
Fax  770.532.3620  

Internet: www.ecomusa.com 

 

For more detailed instructions, 

consult the ECOM-B complete 

manual. 

 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Quick guide 