Ecolink Z-WavePlus Скачать руководство пользователя страница 1

 

  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

© 2015 Ecolink Intelligent Technology Inc. 

 

 

 

 

 

 

 

 

 

 

 

 

 

PN DW-ZWAVE2.5  R1.04

 

Z-WavePlus Siren Installation Instructions 

 

Product Overview 

 

Z-Wave Plus

™ enabled device which can be used to alert the user. 

 

Able to produce 4 different notification sounds 

 

Volume control located on the side of unit. 

 

Z-Wave Plus network range extender. 

 

Product Specifications 

 

For indoor use only 

 

Operating frequency: 908.42 MHz 

 

Operating temperature: 0° 

– 49°C, 32° – 120°F (ambient temperature) 

 

Operating humidity 5-95% non-condensing                                                           

 
 
Network Inclusion 

The Z-Wave Plus Siren must be added to a Z-Wave Plus network prior to use. To include the siren in a network both the siren and the 
network controller must be in inclusion mode at the same time. 

Refer to the instructions provided by the manufacturer of your specific 

controller for details on initiating the controller’s inclusion mode.

  

 

1) 

Verify that the Z-Wave Plus controller you are using is compatible with the Z-Wave Plus Siren. 

2) 

Locate the power outlet desired to be used with the Z-Wave Plus Siren. 

3) 

Put your Z-Wave Plus Controller into add (inclusion) mode.  

4) 

Plug in the Z-Wave Plus Siren and verify a single beep sound is heard. 

5) 

The LED on the front of the unit will turn off if successful included into a network.  
 

Network Exclusion 

1) 

Any Z-Wave Plus Device can be removed from any Z-Wave Plus controller. Follow the directions to put your Z-Wave Plus 
Controller into exclusion mode. 

2) 

Unplug and re-plug in your Z-Wave Plus Siren.   

3) 

The device will play a long beep and the LED will begin to breathe if the device is successfully removed from the network.  

 

 

 

 

 

 

Содержание Z-WavePlus

Страница 1: ...t the same time Refer to the instructions provided by the manufacturer of your specific controller for details on initiating the controller s inclusion mode 1 Verify that the Z Wave Plus controller you are using is compatible with the Z Wave Plus Siren 2 Locate the power outlet desired to be used with the Z Wave Plus Siren 3 Put your Z Wave Plus Controller into add inclusion mode 4 Plug in the Z W...

Страница 2: ...f Note siren volume is not effected by volume knob Siren volume can be increased by connecting the lower jumper Chime Device commanded to sound chime device will send single chime sound Entry Device commanded to play solid tone will remain until commanded off Exit Device commanded to play continuous short beep will remain on until commanded off Device Inputs Volume knob Volume can be increased or ...

Страница 3: ...ink Z Wave Plus Siren Screw for the Siren Jumpers for Siren Options STEP ONE Identify Location for Z wave Siren Determine the location desired for the Z Wave Plus Siren STEP TWO Plug In the Siren to the outlet Screw the Z Wave Plus Siren in if you desire the siren to not easily be removed Upper Jumper Lower Jumper ...

Страница 4: ... integrate the Z Wave Plus Siren into their system Device Classes Generic Device Class GENERIC_TYPE_SENSOR_ NOTIFICATION Specific Device Class SPECIFIC_TYPE_NOTIFICAT ION_SENSOR Command Classes COMMAND_CLASS_ZWAVEPLUS_INFO v2 COMMAND_CLASS_VERSION v2 COMMAND_CLASS_MANUFACTURER_SPECIFIC v2 COMMAND_CLASS_DEVICE_RESET_LOCALLY v1 COMMAND_CLASS_POWERLEVEL v1 COMMAND_CLASS_ASSOCIATION v2 COMMAND_CLASS_A...

Страница 5: ...0xFF will turn on the primary device either siren or chime based on jumper setting A basic set of 0x00 will turn off the primary device A basic set of 0xFF sent to each endpoint will turn on each individual endpoint while a basic set of 0x00 will turn off each individual endpoint Association This siren has one Association groups of 1 node Group one is a lifeline group who will receive unsolicited ...

Страница 6: ...a norme d Industrie Canada exempts de licence RSS Son fonctionnement est soumis aux deux conditions suivantes 1 c et appareil ne peut pas provoquer d interférences et 2 c et appareil doit accepter toute interférence y compris les interférences qui peuvent causer un mauvais fonctionnement de la dispositif FCC ID XQC SCZ5 IC 9863B SCZ5 Warranty Ecolink Intelligent Technology Inc warrants that for a ...

Отзывы: